User manual BEGLEC IR-5C

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BEGLEC IR-5C. We hope that this BEGLEC IR-5C user guide will be useful to you.


BEGLEC IR-5C : Download the complete user guide (1164 Ko)

Manual abstract: user guide BEGLEC IR-5C

Detailed instructions for use are in the User's Guide.

[. . . ] Technical Specifications IR-7S/IR-7B/IR-5C Power Fuse Lamp Dimension Weight AC 120V~60Hz or AC 230/240/250V~50/60Hz 20mm Glass 10A Fast Blow MSD 250/2 695 x 340 x 250 mm (IR-7S/IR-7B) 360 x 340 x 250 mm (IR-5C) 15 kg 9. 2kg (IR-7S/IR-7B) (IR-5C) IR-6S/IR-6B/IR-6SD/IR-6BD/IR-5S/IR-5B/IR-4C Power Fuse Lamp Dimension Weight AC 120V~60Hz 20mm Glass 6. 3A Fast Blow ELC 24V 250W CDM 150W (IR-6SD/IR-6BD) 695 x 340 x 250 mm (IR-6S/6B/6SD/6BD/5S/5B) 360 x 340 x 250 mm (IR-4C) 10. 6 kg (IR-6S/IR-6B/IR-5S/IR-5B) 10. 7 kg (IR-6SD/IR-6BD) 8 kg (IR-4C) AC 230/240/250V~50/60Hz 20mm Glass 5A Fast Blow IS-6S/IS-6B/IS-4/IS-3 Power Fuse Lamp Dimension Weight AC 120V~60Hz 20mm Glass 6. 3A Fast Blow ELC 24V 250W 685 x 380 x 200 mm (IS-6S/IS-6B) 375 x 380 x 200 mm (IS-4/IS-3) 9. 4 kg (IS-6S/IS-6B) 7. 5 kg (IS-4/IS-3) AC 230/240/250V~50/60Hz 20mm Glass 5A Fast Blow User Guide WWW. BEGLEC. COM Innovation , Quality , Performance . 7. Fixture Cleaning The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which TABLE OF CONTENTS 1. Technical Specification 2. 1 Inserting/Exchanging rotating gobos 2. 2 Beam Angel 3. [. . . ] · IR-4C Independent gobo wheel with 14 gobos plus open and blackout, including 7 metal, 1 replaceable, 1 effect, 1 frost, 2 glass, gobos, and 2 color temperature filters (5600k & 3200k), with shaking effect, Independent color wheel with 11 dichroic colors with rainbow effect, and independent shutter & dimmer. · IS-6S/IS-6B/IS-4 Professional multi-gobo rotator 14 gobos plus open and blackout, including 10 metal, 1 replaceable gobo, 2 glass and 1 effect gobos, with shaking and shutter effect, Independent color wheel with 11 dichroic colors with rainbow effect. · IS-3 Professional multi-gobo rotator 14 gobos/colors plus open and blackout, including 10 metal, 1 replaceable gobo, 2 glass and 1 effect gobos, with shaking and shutter effect. 2. 1 Inserting/Exchanging rotating gobos ( For IR-7S/IR-7B/ IR-5C only !Unplug from mains before! Open the cover by loosening the fastening screw at the sides of the cover. If you wish to use other forms and patterns as the standard-gobos, or if the gobos are to be exchanged, remove the fixation ring with an appropriate tool. Press the fixation-ring together and insert it in the front of the gobo. 6A CAUTION!Never unscrew the screws of the rotating gobo as the ball bearing will otherwise be opened! IS-6S/IS-6B/IS-4 ( IS-4 is a 4-channel gobo rotator ) IR-6SD/IR-6BD/IR-6S/IR-6B/IR-4C ( IR-4C is a 4-channel color changer) 7A 2. 2 Beam Angel 3. Lamp In case of replacement of the lamp or maintenance, do not open the fixture within 15 minutes until the unit cools down after switching off. MSD 250/2 GY 9. 5(IR-7S/7B/IR-5C) CDM ( IR-6SD/ IR-6BD ) ELC 24V 250W (IR-6S/IR-6B/IR-5S/IR-5B/ IR-4C/IS-6S/IS-6B/IS-4/IS-3) Diagram for lamp changing Because of its high internal pressure, there might be a risk that the Discharge lamp would explode during operation. The lamp emits intense UV radiation which is harmful to the eyes and skin. The high luminance of the arc can cause severe damage to the retina if looks directly at the lamp. 1. Always switch off the main supply and never 8A handle the lamp or luminaries when is hot. If this happens, clean the lamp with denatured alcohol and wipe it with a lint free cloth before installation. Once the required mode has been selected, press the ENTER button to setup or it will automatically return to the main functions without any change after idling 8 seconds. The main functions are showing below: 5. 3. 1 iSolution Operation Consistent DMX configuration enable iRock and iShow to be linked together and controlled at the same time. DMX address can be set remotely by iLead controller ( please refer to the user manual of iLead controller ). Automatic switching between DMX function and built-in stand alone programs. 5. 3. 2 DMX Controller If you use an universal DMX controller to control the units, you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal. Pressing ENTER Press the MENU button up to when the button and the display will blink. Once the address has been selected, press and keep ENTER button pressed up to when the display stops blinking or storing automatically 8 seconds later. To go back to the functions without any change press the MENU button again. Please refer to the following diagram to address your DMX512 channel for the first 4 units. No need to calculate the DMX 11A channels of each fixture in the chain. ( Following DMX address setting is based on that all the lighting fixtures are linked together controlled by the 8-channel iLead IL-0824 controller. [. . . ] Reset Press the MENU button up to when the is blinking on the display. Pressing ENTER button and all channels of the unit will return to their standard position. To go back to the functions press the MENU button again. ( ) is showing on the display. Press the MENU button up to when the Pressing ENTER button and the display will blink. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BEGLEC IR-5C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BEGLEC IR-5C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.