User manual BANZAI FALLS WATER SLIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BANZAI FALLS WATER SLIDE. We hope that this BANZAI FALLS WATER SLIDE user guide will be useful to you.


BANZAI FALLS WATER SLIDE : Download the complete user guide (6982 Ko)

Manual abstract: user guide BANZAI FALLS WATER SLIDE

Detailed instructions for use are in the User's Guide.

[. . . ] This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in these Operating Instructions. Confirm to authorized dealer or specialist on usage of specified refrigerant type. Using of refrigerant other than the specified type may cause product damage, burst and injury etc. Never use or store gasoline or other flammable vapor or liquid near the air conditioner — it is very dangerous. [. . . ] Refrigerant type: R410A GWP(1) value: 1975 (1) GWP = global warming potential Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your local dealer for more information. 5 01_F568823_EN. fm Page 6 Wednesday, November 7, 2012 10:09 AM INFORMATION Operation Condition Use this air conditioner under the following temperature range. Indoor temperature range: Cooling mode 14°C ~ 25°C (*WBT) / 18°C ~ 32°C (*DBT) Heating mode 15°C ~ 30°C (*DBT) MF2 (3WAY) Outdoor temperature range: Cooling & heating mode -10°C ~ 24°C (*DBT) Cooling mode -10°C ~ 46°C (*DBT) Heating mode -20°C ~ 18°C (*WBT) *DBT: Dry bulb temperature *WBT: Wet bulb temperature Information for Users on Collection and Disposal of Old Equipment and Used Batteries These symbols on the products, packaging, and/or accompanying documents mean that used electrical and electronic products and batteries should not be mixed with general household waste. For proper treatment, recovery and recycling of old products and used batteries, please take them to applicable collection points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC. By disposing of these products and batteries correctly, you will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling. For more information about collection and recycling of old products and batteries, please contact your local municipality, your waste disposal service or the point of sale where you purchased the items. Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation. For business users in the European Union If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information. [Information on Disposal in other Countries outside the European Union] These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal. Note for the battery symbol (bottom two symbol examples): This symbol might be used in combination with a chemical symbol. The unit number is displayed as Outdoor Unit Number–Indoor Unit Number. 2–4 • • • One outdoor unit and eight indoor units No display Unit No. 1–3 11 01_F568823_EN. fm Page 12 Wednesday, November 7, 2012 10:09 AM SPECIAL REMARKS ‘‘DRY’’ Operation How it works • • • • Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically. In order to prevent the humidity in the room from rising again, the indoor fan also turns off when the unit stops operating. The fan speed is set to ‘‘LO. ’’ automatically, and cannot be adjusted. ‘‘DRY’’ operation is not possible if the outdoor temperature is 15 °C or less. Heating Operation Heating performance • Because this appliance heats a room by utilizing the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this heat pump, use another heating appliance in conjunction with this unit. When the outdoor temperature is low, frost or ice may form on the outdoor heat exchanger coil, reducing the heating performance. When this happens, a microcomputer-controlled defrosting system operates. At the same time, the fan on the indoor unit stops (or runs at very low speed in some cases) and the ‘‘STANDBY’’ indicator appears on the display until defrosting is completed. (This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms. ) For several minutes after the start of heating operation, the indoor fan will not start running (or it will run at very low speed in some cases) until the indoor heat exchanger coil has warmed up sufficiently. [. . . ] is sometimes operating for a while even though outdoor compressor is stopped. 13 01_F568823_EN. fm Page 14 Wednesday, November 7, 2012 10:09 AM CHECK BEFORE REQUIRING SERVICES Symptom Cause Remedy Press ON/OFF operation button on remote control unit again. If breaker has been tripped, consult your dealer without turning it on. Air conditioner does not run at Power failure or after power failure all although power is turned on. Poor cooling or heating performance If blown out, consult your dealer. Air intake or air discharge port of indoor Remove dust or obstruction. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BANZAI FALLS WATER SLIDE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BANZAI FALLS WATER SLIDE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.