User manual ATIKA COMET 130 S

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ATIKA COMET 130 S. We hope that this ATIKA COMET 130 S user guide will be useful to you.


ATIKA COMET 130 S : Download the complete user guide (3055 Ko)

You may also download the following manuals related to this product:

   ATIKA COMET 130 S (2405 ko)
   ATIKA COMET 130 S BROCHURE (1580 ko)
   ATIKA COMET 130 S BROCHURE (2405 ko)
   ATIKA COMET 130 S BROCHURE (2405 ko)
   ATIKA COMET 130 S BROCHURE (2405 ko)
   ATIKA COMET 130 S BROCHURE (2405 ko)
   ATIKA COMET 130 S BROCHURE (2405 ko)
   ATIKA COMET 130 S BROCHURE (2405 ko)
   ATIKA COMET 130 S BROCHURE (2405 ko)
   ATIKA COMET 130 S BROCHURE (2405 ko)
   ATIKA COMET 130 S BROCHURE (2405 ko)

Manual abstract: user guide ATIKA COMET 130 S

Detailed instructions for use are in the User's Guide.

[. . . ] only use the mixer for the functions listed in "Proper use". Only start up the mixer if the protective devices are complete and undamaged. Do not reach into mixer when it is rotating mixing running ( apparatus). Concrete mixers which the manufacturer has not intended for towed vehicle operation may only be run by means of a hand wire pull. [. . . ] When you look into the mixing drum, it must turn to the left (counter-clockwise). If the mixing drum turns in the opposite direction from the arrow, the rotating direcion can be changed by inderting a screwdriver for this purpose and turn left or right while exerting a light pressure to adjust the correct rotating direction. Connecting attachments must be designed in conformance with IEC 60245-4:1980 (DIN 57 282) and marked H 07 RN-F, or comparable models. Use only connecting attachments with a rubber plug for severe requirements that is protected device against spraying water. When laying the connecting attachments, be sure that they do get crushed or bent, and that the plug-and-socket connection does not get wet. Observe the following instruction in Switzerland: Only hook up locomotive units used outdoors by means of a fault-current circuit breaker. Mixer setting: To make concrete or mortar, the mixing drum must be locked in a specific position. Only the proper mixer setting ensures optimal mixing results and smooth operation. Concrete mixer with adjusting disc Rotating level Handwheel A licensed professional electrician must make all electrical connections and repairs, and observe local regulations in doing so, especially those regarding protective measures. The manufacturer or a company designated by the manufacturer must attend to the repair of all electrical parts on the machine. When setting up the machine, make sure that the mixing drum can be emptied without obstruction. Point the opening of the mixing drum downwards during transport or storage. Step on the brake Rotate the mixing drum up to the marking appropriate for the material you are mixing release brake · In order to increase the service life of the concrete mixer and operate it without glitches, the rotating mechanism should be treated with an environmentally compatible spray oil before the mixer is put into storage for unusually long periods. Switch off machine and pull plug if you have to touch the machine (with hand, brush, scraper, rag, etc. Protective devices removed for cleaning must be properly remounted before starting the machine. Do not spray water directly on the motor or the switch, nor on the ventilation apertures in the motor housing. notes on cleaning: · Before taking a break and after finishing work, clean the concrete mixer inside and out. Do not pound on the mixing drum with hard objects (hammer, shovel, etc. A dented mixing drum impairs mixing operations and is difficult to clean, besides. To clean the inside of the drum, put in some water and a few shovels full of gravel and set the drum to revolving. Remove any concrete or mortar left sticking to the teeth of the axle-drive bevel gear or the crown gear segments immediately. Repeat steps 1 and 2 until you reach the proportions required for mixing. [. . . ] Protective devices removed for repairs must be properly remounted before starting the machine. Only the manufacturer or companies authorised by the manufacturer may perform repair work on electrical parts or on parts which affect the space needed to mount electrical equipment. Malfunction Motor does not start up Possible cause no mains voltage defective cable thermostat is triggered reason: - motor overload - motor not getting enough air owing to clogged ventilation apertures Motor hums but does not blocked crown gear start up defective condenser Remedy check fuse protection have checked or replaced (electrician) allow motor to cool and then find and eliminate whatever caused the thermostat to respond Switch off machine, pull plug and clean or replace the crown gear segments send machine to manufacturer or a company designated by the manufacturer for repairs Machine starts up, but extension cord is too long or its cross-section extension cord must be at least 1. 5 mm² for a becomes blocked at low is too small maximum length of 25 m; the cross-section load and may switch off socket is too far from mains connection and of longer cables must be at least 2. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ATIKA COMET 130 S




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ATIKA COMET 130 S will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.