User manual ATIKA ASP 10 N BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ATIKA ASP 10 N. We hope that this ATIKA ASP 10 N user guide will be useful to you.


ATIKA ASP 10 N BROCHURE: Download the complete user guide (3869 Ko)

You may also download the following manuals related to this product:

   ATIKA ASP 10 N BROCHURE (808 ko)
   ATIKA ASP 10 N AUTRE BROCHURE (616 ko)

Manual abstract: user guide ATIKA ASP 10 NBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Declaration of Conformity Spare parts / Description of device Assembly Extent of delivery Symbols Proper use Residual risks Safe working Transport instructions Positioning Start-up Working with the log splitter Care and maintenance Guarantee Technical data Possible problems 1 2 4 16 16 17 17 17 18 18 18 19 22 23 24 24 > > After unpacking, check the contents of the box That it is complete Check for possible transport damage Report any damage or missing items to your dealer, supplier or the manufacturer immediately. 1 ready mounted machine unit 1 table plate 1 control arm, right 1 control arm, left 1 axle 1 bag of accessories 1 operating manual 2 wheels Hold the work piece when splitting with the clamping claw. Read the operating and safety instructions thoroughly before commissioning the machine. Before starting any repair, maintenance or cleaning work, always switch off the motor and remove the plug from the socket. [. . . ] Move the splitting blade right down every time before the machine is transported. to transport the machine , grasp the handle and tilt the transport belt log splitter slightly towards you. Make sure that the oil tank cap is securely tightened to prevent oil from leaking during transport. Electrical connections must conform to IEC 60245 (H 07 RN-F) with a cable cross-section of at least 230 V ~ 3 x 1. 5 mm² for a maximum cable length of up to 10 m Never use the machine with a power supply cable of over 10 m in length. The motor will not be able to provide its maximum performance and the operation of the machine will be impaired. Plugs and coupler outlets on connection cables must be made of rubber, plasticised PVC or other thermoplastic material of same mechanical stability or be covered with this material. When running the connection line observe that it does not interfere, is not squeezed, bended and the plug connection does not get wet. Regularly check the extension cables and replace them if they are damaged. When working outdoors, only use extension cables especially approved and appropriately labelled for outdoor use. The electrical connection or repairs to electrical parts of the machine must be carried out by a certified electrician or one of our customer service points. Local regulations ­ especially regarding protective measures ­ must be observed. Repairs to other parts of the machine must be carried out by the manufacturer or one of his customer service points. Accidents can arise for the user through the use of other spare parts. Ensure that the working area meets the following conditions: - no danger of slipping - level - free of obstacles - sufficiently well lit Do not operate the machine in the direct vicinity of gas or petrol pipes or containers, or any other easily inflammable materials. Before using the log splitter, make sure each time that - there are no faulty connections (tears, cuts, etc. - there are no damages at the machine - all screws are tight - check the hydraulic system for any possible leaks - the oil level The transport closure must be replaced by the oil dipstick before start up the machine. Lock in case of power (zero-voltage initiator) The equipment will switch off automatically if there is a power cut. Make sure that the motor turns in the correct direction (see motor arrow), because operation in the wrong direction damages the oil pump. switch on motor; the splitting blade automatically moves to the highest position. If the splitting blade is already in its highest position: grip both operating handles and push them down. If the splitting blade does not move after the motor has started, switch off the motor and change the direction of rotation. [. . . ] If the problem cannot be rectified, refer to the manufacturer or other approved service centre. Release rods bent (hydraulic tappet not Arrange for manufacturer or authorised company to adjust the rods. Incorrect connecting lead (longer than 10 m Use the correct connecting lead. Unsteadily or with strong Splitting column not sufficiently lubricated or Lubricate splitting column or oil with vibrations. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ATIKA ASP 10 N




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ATIKA ASP 10 N will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.