User manual ATIKA ALE 600

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ATIKA ALE 600. We hope that this ATIKA ALE 600 user guide will be useful to you.


ATIKA ALE 600 : Download the complete user guide (7825 Ko)

You may also download the following manuals related to this product:

   ATIKA ALE 600 (2543 ko)
   ATIKA ALE 600 BROCHURE (756 ko)
   ATIKA ALE 600 BROCHURE (2543 ko)
   ATIKA ALE 600 BROCHURE (2543 ko)
   ATIKA ALE 600 BROCHURE (2543 ko)
   ATIKA ALE 600 BROCHURE (2543 ko)
   ATIKA ALE 600 BROCHURE (2543 ko)
   ATIKA ALE 600 BROCHURE (2543 ko)

Manual abstract: user guide ATIKA ALE 600

Detailed instructions for use are in the User's Guide.

[. . . ] Before commissioning this product, read and keep to the following advice. Also observe the accident prevention rules of your professional association and the safety provisions applicable in the respective country, in order to protect yourself and others from possible injury. Pass the safety instructions on to all persons who work with the machine. Make yourself familiar with the equipment before using it, by reading and understanding the operating instructions. [. . . ] Repairs to other parts of the machine must be carried out by the manufacturer or one of his customer service points. Accidents can arise for the user through the use of other spare parts. The manufacturer is not liable for any damage or injury resulting from such action. If possible, the air dehumidifier should be placed in the middle of the room in order to have a good air circulation in the whole room. If this is not possible, locate the air dehumidifier so that air can be sucked and discharged unhindered. Place the air dehumidifier horizontally to ensure that the condensed water can flow off unhindered away from a heat source (e. Make sure that windows and doors of the room to be dehumidified are closed. Use an electrical socket with a rated voltage of 230 V with a fault-current circuit breaker (30 mA). This air dehumidifier works on the basis of the condensation principle. Room air is sucked through a filter and a refrigerating element where water vapour in the air condense as water droplets. Then, the water droplets flow into a condensation water bowl and further into the water container while the dried cold air is piped through the condenser of the device, heated and blown again into the room. This increase of heat is caused by power introduced in the compressor and fan and by heat which is released by the condensation of the water vapour. The relative humidity of air is gradually reduced thanks to continuous recirculation of the room air through the device resulting in a quick and gentle drying of the room. Therefore, it is essential to "seal" the room as tight as possible. That means doors and windows must kept closed and entering and leaving the room should be restricted if possible. Did you transport the air dehumidifier in horizontal position or at an angle large than 45°?The air dehumidifier will not work if the set humidity value is higher than that of the environment. Only use the air dehumidifier at a room temperature between 5 °C and 32 °C. Once the compressor has been started the fan motor and the compressor must run for at least 3 minutes during dehumidification. To prevent damages to the compressor, you should wait for 3 minutes after a shut-down of the air dehumidifier before you restart the device. If the room temperature is under 10 °C and the relative humidity of the ambient air is rather low an operation of the air dehumidifier will not be necessary. The device's air dehumidification performance depends on room design, room temperature and relative humidity of the room air. [. . . ] Immediately put the device out of operation if it does not function properly. Following fault codes can be indicated in the display 2 "Relative humidity of air": Fault code E3 E4 E5 Fault Humidity sensor defective. Please contact the manufacturer or customer service of the fault codes E3 or E5 appear. Current consumption Power, fan Electrical power supply Power system fuse protection Temperature range Humidity of air range Dehumidification performance at 30 °C / 80% RH Degree of protection Freezing pressure Vapour pressure Refrigerant Refrigerant quantity Container volume, max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ATIKA ALE 600




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ATIKA ALE 600 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.