User manual ASL INTERCOM PS 280

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ASL INTERCOM PS 280. We hope that this ASL INTERCOM PS 280 user guide will be useful to you.


ASL INTERCOM PS 280 : Download the complete user guide (61 Ko)

Manual abstract: user guide ASL INTERCOM PS 280

Detailed instructions for use are in the User's Guide.

[. . . ] If any damage has occured, please notify your dealer immediately so that a written claim can be initiated. Please also refer to the guarantee section of this manual. The shipping carton contains the parts listed below. * The PS 280 * Mains power cable * Spare fuses * User manual If any are missing contact your dealer. There is also one spare fuse included in the mains inlet. 3. 0 MECHANICAL INSTALLATION The power supply regulator is mounted on the rear of the unit, and after a period of time it will feel hot to the touch. [. . . ] Plug the other end of the power cord into a PROPERLY GROUNDED outlet. - 2 User Manual PS 280 / Issue 1 © 1994 ASL Intercom, Utrecht, Holland. - Turn on the power with the red button. The red overload LED will light up for about 3 seconds, then extinguishes and then the green power LED will go on, indicating the station is active. See for further installation and operation the concerning sections. User Manual PS 280 / Issue 1 © 1994 ASL Intercom, Utrecht, Holland. 3 5. 0 FRONT PANEL CONTROLS 1 POWER ON/OFF switch Mains power push button for switching ON and OFF the internal power supply. OVERLOAD LED This LED illuminates if the internal power supply has shut off line power due to overload. If the internal power supply is overloaded (too many user stations are connected or short-circuit in the interconnecting cables or thermal overload), it activates a circuit-breaker which immediately shuts off line power. This circuit breaker resets automatically 3 seconds after the overload situation is terminated, restoring line power automatically. During short-circuit, the overload LED extinguishes very shortly every 3 seconds. This overload LED also comes on every time you switch on the main power. 3 POWER LED This LED illuminates if line power is supplied by the internal power supply. ALL MIC'S ON/OFF button With this pushbutton all microphones of the connected stations can be muted. ALL BUZZERS ON/OFF button With this button all buzzers of the connected stations can be muted. AUX VOLUME control knobs These knobs adjusts the level of the aux input signal to each of the two intercom lines. 2 4 5 6 6. 0 REAR PANEL CONTROLS & CONNECTORS 7 A & B LINE connectors These XLR-3 type connectors are for connecting user stations, via standard microphone cable. There are two connectors for channel A and two connectors for channel B. audio wire 9 FUSE This fuse protects the PS 280 against severe internal damage, in case of malfunction in the power section. It is most important to place the correct fuse in the holder : mains voltage fuse 220 - 240 VAC T 315 mA 100 - 120 VAC T 630 mA Spare fuses will be found in the small packet supplied with the unit. 8 AUX INPUT connector This XLR-3 type aux input is electronically balanced and accepts audio levels between -18dBu to +22dBu on line level, and -38dBu to +2dBu on mic level. Signal When mic level is selected, a +30V DC phantom power is supplied to pins 2 and 3. 10 MAINS INLET IEC Mains connector. For correct wiring and operation refer to section 4. 0. WARNING Before you plug in the mains voltage, check if: The fuse is correct The voltage is correct 4 User Manual PS 280 / Issue 1 © 1994 ASL Intercom, Utrecht, Holland. 7. 0 CABLING For the PRO Series Intercom system the interconnecting cables are of the shielded two-conductor microphone cable type and the intercom line connectors are of the XLR-3 type. XLR pin 1 is connected to the shield of the cable which functions as the common return for audio and power. Since the audio signal is transferred in an unbalanced * way, certain rules have to be obeyed when installing the cables of an intercom network. This in order to avoid earth loops and to minimize power loss and the possible effect of electromagnetical fields. For interconnecting user stations, power supplies and accessories in an ASL Intercom network, use high quality shielded two-conductor (minimum 2x 0. 30 mm2) microphone cable only. In case of a multi channel intercom network, use high quality microphone 'multipair' cable only, each pair consisting of two conductors (minimum 2x 0. 15 mm2) with separate shield. [. . . ] Intercom cables should never be in the same (metal) trunks with energy cables. In order to avoid unacceptable power losses, place the power supplies as close as possible to where most power consumption occurs or, in other words, most user stations are placed. The ASL power supply may be connected to the mains power outlet to which other audio equipment is connected. Avoid using mains outlets which also power dimmer controlled lighting systems. In case of more complex installations, don't hesitate to contact us. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ASL INTERCOM PS 280




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ASL INTERCOM PS 280 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.