User manual APRIMATIC T1E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual APRIMATIC T1E. We hope that this APRIMATIC T1E user guide will be useful to you.


APRIMATIC T1E : Download the complete user guide (1405 Ko)

Manual abstract: user guide APRIMATIC T1E

Detailed instructions for use are in the User's Guide.

[. . . ] The strict observance of these instructions grants safe conditions, an efficient operation and a long life of the product. To prevent operations that can result in accidents, read this manual thoroughly and obey its instructions. Device with Aprimatic microprocessor designed to drive 2 motors with a maximum power of 300 Watt each. Mains presence LED DL4 Photocell LED Start LED DL5 Pedestrian start LED Stop LED Power terminal board P1 Work time trimmer Signal terminal board P2 Pause time trimmer Connector for decoding badge reader and coded keypad or Radio receiver socket for Aprimatic models only (ONLY for T1E) N. [. . . ] In this case, the operator must release the push-buttons and press either close or open. This is also the case if the two push-buttons are pressed at the same time. If you select this operating mode, when a pulse is given, opening is commanded until the work time expires, the gate remains open for the selected pause time and it then closes automatically. ⷠIf a pulse is sent during opening, the control system ignores it and the gate continues to open. ⷠIf a pulse is sent or the photocells are obscured during closing, the direction is inverted (the gate re-opens). ⷠDuring the pause stage and when the photocells are obscured, the device will remain in pause until the photocells are cleared. If you select this operating mode when the gate is closed, when a start pulse is given, the gates open until the set work time expires. If another start pulse is given during opening, the gates stop immediately until another start pulse is given: this closes the automation. When you select this type of operating and a start pulse is given, the gate opens as far as the limit switch and stays open for the pre-set pause time and then closes automatically. A start pulse given during any stage reverses the direction: you can close the gate with a command. DIP-SWITCHES 4 and 5 (GATE CLOSING DELAY) - These SWITCHES are used to adjust the gate closing delay for motor 1 (delayed closing), compared to the start up of motor 2 (immediate). If the function is enabled, before the automation opens or closes, there will be a signal for 3 seconds and the warning light and flashing lights will come ON before the gates move. DIP SWITCH 7 (PAUSE PHOTOCELL) - This SWITCH is used to select the pause photocell function when the automatic functioning mode is enabled. When the SWITCH is in the ON position, if the photocell beam is interrupted and cleared with the automation in pause, the device will command pre-flashing for 3 seconds and will then close the gate, even if the pause time has not been concluded. When the SWITCH is in the OFF position, the gate will only close when the set pause time expires. When the SWITCH is in the ON position, the input functions as an opening safety device. When the SWITCH is in the OFF position, the input is enabled for single wing functioning (motor 1). nOTE - This selection (ON/OFF) is valid for all operating modes , except Dead Man mode. JP5-8 (ENABLING BUTTON) - Using the jumpers JP5-8, you can select which receiver output channel and, therefore, which remote control button, will enable the output signal. This selection is made by closing just one of the jumpers present, following the scheme indicated below: WARNING: Only close one jumper or you risk breaking the unit ! JP3-4 (ENABLING BUTTON ROW) - The receivers may be used with 2-4 or 14-button remote controls. If you use it with a 14-button remote control, you can use the jumpers JP3 and JP4 to define which row of buttons the receiver must respond to, following the scheme indicated below: JP3 ­ JP4 open: row 1 (Buttons 1-4) JP3 closed: row 2 (Buttons 5-8) JP4 closed: row 3 (Buttons 9-12) JP3 ­ JP4 closed: row 4 (Buttons 13-14). [. . . ] ⷠDuring the self-teaching procedure, the device outputs are disabled. 1 CA41 MODULE (FOR T11) By fitting this module to the device, the user will have an additional receiving channel: in this way, with the SAME DEVICE AND THE Aprimatic two-key STANDARD REMOTE CONTROL, he will be able to control two different appliances. With the device powered up, hold down the delete button: the DL6 LED and the BZ1 buzzer come on (continuous buzzer). Accessory card for activating the anti-crush function for both motors. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE APRIMATIC T1E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual APRIMATIC T1E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.