User manual APPLIED ENERGY PX9

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual APPLIED ENERGY PX9. We hope that this APPLIED ENERGY PX9 user guide will be useful to you.


APPLIED ENERGY PX9 : Download the complete user guide (379 Ko)

Manual abstract: user guide APPLIED ENERGY PX9

Detailed instructions for use are in the User's Guide.

[. . . ] 22721AA) Installation and maintenance instructions 2 7 Installing the Fan 5. Preparing the hole If working above ground floor level, appropriate safety precautions must be observed. WARNING: EYE PROTECTION MUST BE WORN DURING ALL DRILLING OPERATIONS. G1 These appliances are intended for connection to fixed wiring. Check that the electrical rating shown on the fan match es the mains supply. WARNING: THESE APPLIANCES MUST BE EARTHED. All installations must be supervised by a qualified electrician. [. . . ] · If metal switch boxes are used, earthing regulations must be followed. · Suitably rated 3-core cable (see `Installing switches and cables' section). · 6mm blade large screwdriver, 3mm blade electrician's screwdriver and No. If installing the fan with an on/off switch: · On/Off switch If installing the fan with a controller (PX9/12 only): · Suitably rated 5-core cable. Wire the electrical connections If installing a PX6: 1. Wire the switch cable into the fan's terminal connector as shown in diagram B2. If the Fan is wired from above, remove the fan's Terminal cover and feed the cable through the top cable entry. If wiring from the rear, remove the fan's terminal cover and rear entry knockout, feed the cable through the knockout. Refit the inner grille to the fan mounting box, using fixi ng screws G1 (8). Insert two colour matching screw covers in the fixing holes in the inner grille. When removing the covers, place a 3mm blade electrician's screwdriver into the slot and lever off the cover. Connect the cable from isolation switch to the electrical supply wiring. For fixed wiring circuits the protective fuse for the appliance must n ot exceed 5A. If required feed the cable through the grommet in order to fit the cable entry of the connector plate. Set the Fan Selector Switch to position 1 for Intake, Position 2 for Extract or Position 3 for `open shutter only' (Fig D. ) · If installing with a controller: 1. If wiring to an existing controller, contact Xpelair Technical Services or in export markets, the Xpelair distributor 3. Set the Fan selector Switch to position 3 if using a controller providing variable sp eed and/or direction. Otherwise, set the Fan Selector Switch to Position 1 for Intake, Position 2 for Extract or Position 3 for `open shutter only' (fig. Fitting the cable clamp (PX9/12): For cable up to 8mm diameter, clamp the cable as shown in Fig. For cable equal to or greater than 8mm and up to 11. 5mm diameter, clamp the cable as shown in Fig. For cable greater than 11. 5mm diameter use the conduit entry provided (Europe only). Assembly the Fan Connector by snapping the Cover over the Connector (Fig. If installing a PX6: · At least 200mm from the edge of the wall or ceiling to the centre of the hole. [. . . ] For fixed wiring circuits the protective fuse for the appliance must not exceed 5A. C PX6 D 9. Operating the fan Switch operated: · To switch on and off, use the switch on the wall or ceiling. Controller operated (PX9/12 only): · Refer to the instructions for the controller. · The shutters have a time delay of up to 1 minute on opening, and up to 3 minutes on closing. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE APPLIED ENERGY PX9




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual APPLIED ENERGY PX9 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.