User manual APPLIED ENERGY POWERSTREAM

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual APPLIED ENERGY POWERSTREAM. We hope that this APPLIED ENERGY POWERSTREAM user guide will be useful to you.


APPLIED ENERGY POWERSTREAM : Download the complete user guide (1664 Ko)

Manual abstract: user guide APPLIED ENERGY POWERSTREAM

Detailed instructions for use are in the User's Guide.

[. . . ] IMPORTANT: This booklet should be given to the customer after installation and demonstration. Applied Energy Products Limited Fixing to the wall q Undo the retaining nuts and take the front cover off the unit. Hold the backplate in position against the wall while you mark the four fixing holes. q Drill the holes and fix the unit to the wall using the four No 8 x 38mm wood screws supplied. [. . . ] For non UK customers please contact your local distributor. If you have any queries See page 10, then call the Redring Technical Advisory Hotline on 01733 456999. If you need further information, we will be glad to help you with any installation enquiries. - IMPORTANT Demonstrate the unit to the user and give them this guide. Flow rate (litres/min) Summer temp oC Winter temp oC 3. 0 50o 4. 0 54o 39o 6. 0 43o 28o Flow rate (litres/min) Summer temp oC Winter temp C o 4. 0 44 o 5. 0 51o 36 o 6. 0 46o 31o Flow rate (litres/min) Summer temp oC Winter temp oC 5. 0 54o 39o 6. 0 49o 34o 7. 0 44o 30o For the Installer Symptom Cause What to do Use a pump to boost the supply from a storage tank. Reset it by opening the unit and pushing the button on the cut-out (diagram 10. ) Before you do this you must remove the cause of the problem. Switch off the electricity supply & check the resistance of the elements. You should get the following readings: Loading kW 9. 5 10. 8 12 The Power Supply Voltage has dropped. Resistance 12 10. 6 9. 6 Little or no water flows - The water pressure is very low. The water pressure is too low. The thermal cut-out has triggered. The flow switch is not working. One element is not working (neon dim). The Heater should draw the following currents; 40 amps for the 9. 5kW model 45 amps for the 10. 8kW model 50 amps for the 12 kW model Change the brass jet for one with a smaller hole. Fit the service valve to the INLET of the unit. The flow switch is not set correctly. Fit the service valve valve to the INLET of the unit. For the User Symptom Little or no water flows Cold water only - neon light off. Cause The main water supply is turned off. The filter is blocked or the brass jet is wrongly positioned What to do Turn on the main supply fully at the stop valve. For a shower, adjust the spray pattern available on the multi-mode handset. Water too cold - neon light on. The water flow rate is too high. The inlet water temperature has dropped. Water flow too low, or temperature too high The main supply water flow is too low. [. . . ] c) The appliance has not been taken apart, modified or repaired except by a person authorised by us. d) Evidence of the date of purchase in the form of an invoice, receipt (hire purchase documents) is included with the appliance if returned under guarantee. e) For non UK customers please contact your local distributor. `This guarantee does not affect your statutory rights' Full details of Terms and Conditions of guarantee are available on request from:­ Applied Energy Products Ltd. , Morley Way, Peterborough, PE2 9JJ. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE APPLIED ENERGY POWERSTREAM




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual APPLIED ENERGY POWERSTREAM will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.