User manual APPLIED ENERGY DIGITEMP

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual APPLIED ENERGY DIGITEMP. We hope that this APPLIED ENERGY DIGITEMP user guide will be useful to you.


APPLIED ENERGY DIGITEMP : Download the complete user guide (2793 Ko)

Manual abstract: user guide APPLIED ENERGY DIGITEMP

Detailed instructions for use are in the User's Guide.

[. . . ] THESE APPLIANCES ARE DOUBLE INSULATED AND DO NOT REQUIRE AN EARTH CONNECTION. Installations and wiring must conform to current IEE Regulations (UK), local or appropriate regulations (other countries). If you have any queries before installing these products or after they have been installed, contact the Xpelair Technical Hotline (details overleaf), or outside the UK contact your distributor. If installing in a wall 1. Check there are no buried pipes or cables in the wall or obstructions on the outside e. g. [. . . ] (The recommended method is to drill a series of holes, close together, around the edge of the cutting line and remove the brick between the holes with a chisel). Go outside and cut a hole in the outer wall, repeating the process described above. Ensure that the duct slopes down away from the fan to allow drainage of any incoming rain water to the outside. Allow the mortar to set before continuing with the fan installation. Description DIGITEMP DIGITEMPP DIGITEMPT DIGITEMP Range fans have the following features: · Single speed operation. · Built-in timer operates fan for a preset delay of 20 minutes. If installing in a window or panel 1. Cut a hole, 125mm in diameter or if installing in a window, obtain a ready cut pane. The centre of the hole should be at least 110mm away from the edge of the panel or pane of glass. · A double pole isolating switch with a minimum contact gap of 3mm in each pole (wall or ceiling mounted). · If metal switch boxes are used, earthing regulations must be followed. · To prevent a possible hazardous situation from water ingress, an appropriate condensation trap (Xodus XCT100) must be fitted as close as possible to the fan in all situations where any section of the ductwork is positioned higher than the fan itself. What the installer will need If installing in a ventilation shaft 1. Cut a hole 110mm in diameter, in the side of the shaft. If installing in a ceiling 1. Check there are no buried pipes or cables in the ceiling above the fan location. · Exhaust air must not be discharged into a flue used for exhausting of fumes from appliances supplied with energy other than electric. Requirements of all authorities concerned must be observed for exhaust air discharge and intake flow rates. · When intended for use in possible chemical corrosive atmospheres, consult our Technical Department or your distributor. · This electrical product is rated at "IPX5", and can be installed anywhere in a shower room or bathroom. Check that the electrical rating shown inside the backplate matches your mains supply. electricity, gas, water behind the switch location (in the wall or above the ceiling). Lay in the cable from the isolating switch to the fan location via the on/off switch (if required). Lay in the cable from the isolating switch to the point of connection to the mains supply. Warning: Do not make any connections to the electrical supply at this stage. Make all connections within the isolating switch and the on/off switch (if required). Note: on/off switch must be situated so that it cannot be touched by persons making use of the bath or shower. [. . . ] If in doubt, seek professional advice. Where to locate the fan If installing in a window or panel 1. If installing in a window or panel no more than 9mm thick, a XXGK4 Glass Kit is required. Follow instructions supplied. Wire the electrical connections · Make sure the mains supply is isolated. · All wiring and installation must be supervised by a qualified electrician. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE APPLIED ENERGY DIGITEMP




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual APPLIED ENERGY DIGITEMP will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.