User manual APOGEE ENSEMBLE
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual APOGEE ENSEMBLE. We hope that this APOGEE ENSEMBLE user guide will be useful to you.
Manual abstract: user guide APOGEE ENSEMBLE
Detailed instructions for use are in the User's Guide.
[. . . ] MultiChannel, 24bit/192kHz Audio Interface for the Macintosh User's Guide
v1. 1 October 2006
User's Guide
Table of Contents
Owners Record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Getting Started Quickly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] CD Mode Checking this box sends a 44k1, 16bit stereo signal to the S/PDIF Coax output, regardless of the DAW session sample rate or bit depth. CD Mode sets UV22HR to S/DPIF Out, and if the DAW session is at any other sample rate than 44k1 sets SRC Select to S/PDIF Out and SRC Rate to 44k1. Disable Loop Sync When checked, Loop Sync automatic clock selection is disabled on all connected Ensembles . Check this box when clocking multiple Ensembles directly from one Master clock source, such as Apogee's Big Ben. Hold Overs By checking this box, the red Over indicators on the front panel meters and in Maestro's Settings/Output page remain lit until the Clear Meters button (in Maestro's Mixer window) is clicked.
14
Ensemble User's Guide
APOGEE ELECTRONICS
Maestro Settings Control Panel
18
Input Settings : Soft Limit When checked, Apogee's Soft Limit overload protection is engaged on the corresponding Analog input. Input Settings : +4, 10, MIC The nominal reference level of each analog input is selected with these radio buttons. Inputs 14 may also be set to MIC level, allowing gain to be set from +10 to +75 dB.
18
Output Settings The nominal reference level of each analog output is selected with these radio buttons.
15
Ensemble User's Guide
APOGEE ELECTRONICS
Maestro Settings Output
1
Level Control Three knobs provide level control for the Main, HP1 and HP2 outputs. Output attenuation from 0 to 127 dB is displayed in a corresponding readout. Meter Display Signal present on any channel selected in the MAIN Format Select or HP 12 Source Select drop down lists is displayed on the corresponding meter. MAIN Format Select This drop down list is used to configure the analog outputs for various monitoring situations. When Format is set to None, all Analog outputs function as standard Line outputs; the Main Level fader has no function. When Format is set to Stereo, the Main Level fader (and front panel Output encoder) controls the level of Analog outputs 12. When Format is set to 5. 1 Surround, the Main Level fader (and front panel Output encoder) controls the level of Analog outputs 16. When Format is set to 7. 1 Surround, the Main Level fader (and front panel Output encoder) controls the level of all the Analog outputs.
2
3
4
HP1 HP2 Source Select These drop down lists are used to select the stereo signal source for the front panel headphone outputs.
Maestro Settings Mic Pre
Pre1 Pre4 The following controls are provided for Pre1Pre4
1
Gain Control This knob provides gain control for the mic pre. Mic pre gain from +10 to +75 dB is displayed in a corresponding readout. Meter Display This meter displays the conversion level of the corresponding channel, for a convenient reference when setting mic pre gain. Groups The Gain Control of two or more Pres may be linked by selecting the same Group in this drop down list. The Gain offset present when Pres are initially grouped is maintained after grouping. Phase When this box is checked, polarity of the corresponding analog input is inverted. 48V When this box is checked, 48 volt phantom power is applied to the corresponding XLR input. SoftLimit When this box is checked, Soft Limit overload protection is applied to the corresponding analog input.
2
3
4
5
6
16
Ensemble User's Guide
APOGEE ELECTRONICS
Maestro Settings Output
Maestro Settings Mic Pre
17
Ensemble User's Guide
APOGEE ELECTRONICS
Navigating the Front Panel
1 2 5 7 9
3
4
6
8
10
11
12
1 1.
Power Switch Press this button to apply power to Ensemble. When Ensemble's AC input is connected, the switch will light dimly to indicate that the unit is in Standby. [. . . ] Declaration of Conformity CE Apogee Electronics Corporation hereby declares that the product, the Ensemble, to which this declaration relates, is in material conformity with the following standards or other normative documents: · EN500811/EN55022; 1995 · EN500821/IEC 8012, 3, 4; 1992 following the provisions of: · 73/23/EEC Low Voltage Directive · 89/336/EEC EMC Directive Declaration of Conformity Japan Apogee Electronics Corporation hereby declares that the Ensemble, to which this declaration relates, is in material conformity with the VCCI Class A standard. Declaration of Conformity Australia Apogee Electronics Corporation hereby declares that the Ensemble is in material conformity with AN/NZS standard requirements.
27
Ensemble User's Guide
APOGEE ELECTRONICS
Registration and Warranty Information
Be sure to register your Ensemble, either by filling in the enclosed Registration Card or by completing the online registration form at our Web site: http://www. apogeedigital. com/support/. As enhancements and upgrades are developed, you will be contacted at the registration address. Firmware updates are free for the first year of ownership unless otherwise stated. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE APOGEE ENSEMBLE
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual APOGEE ENSEMBLE will begin.