User manual APC SMART-UPS 2200VA LCD 230V

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual APC SMART-UPS 2200VA LCD 230V. We hope that this APC SMART-UPS 2200VA LCD 230V user guide will be useful to you.


APC SMART-UPS 2200VA LCD 230V : Download the complete user guide (367 Ko)

Manual abstract: user guide APC SMART-UPS 2200VA LCD 230V

Detailed instructions for use are in the User's Guide.

[. . . ] Do not expect full runtime during this initial charge period. 2200 and 3000 VA 1000 and 1400 VA 450 and 700 VA norm al reduced low Connect Computer Interface Port (Optional) Power management software and interface kits can be used with this UPS. If used, connect the interface cable to the 9-pin computer interface port on the back panel of the UPS. Connect Ground Leads to TVSS Connector (Optional) The UPS features a TVSS connector for connecting the ground lead on transient voltage surge-suppression (TVSS) devices such as telephone and network line protectors. The TVSS connector provides grounding through the UPS's power cord ground conductor. [. . . ] If the replace battery LED is still on, replace the battery using the Replacing the Battery procedure. SmartTrim The SmartTrim LED comes on to indicate that the UPS is compensating for a high voltage. SmartBoost The SmartBoost LED comes on to indicate that the UPS is compensating for a low voltage. When the UPS is operating on-battery and the energy reserve of the battery runs low, the UPS beeps continuously until the UPS shuts down from battery exhaustion or returns to on-line operation. Overload When loads exceed the UPS's capacity, the overload LED illuminates, the UPS emits a sustained tone, and the input circuit breaker may trip (the resettable center plunger of the circuit breaker pops out). Disconnect nonessential load equipment from the UPS to eliminate the overload. If there is AC power and the circuit breaker does not trip during overload, the loads are still powered. If the circuit breaker trips and the UPS attempts to go on-battery, the output AC will shut down. Cold Start When the UPS is off and there is no utility power, it is possible to cold start the UPS to power the loads from the UPS's battery. Note: Cold start is not a normal condition. · 100% 80% 60% 40% 20% Battery Charge Bar Graph The 5-LED display on the right of the front panel shows the present charge of the UPS's battery as a percentage of the battery's capacity. When the LEDs are flashing, the battery can supply less than the "low battery warning interval" time for the load. Press and hold the on/test button until the UPS begins beeping. Battery replacement is a safe procedure, isolated from electrical hazards. See your dealer or call the number in this manual for information on replacement battery kits. Once the battery is disconnected, the loads are not protected from power outages. Unhook the bottom section of the front cover from the chassis and set it aside. Use a flat-blade screwdriver or a coin to remove the two battery door screws and open the door. Grip the wires for the front set of batteries and pull firmly to disconnect the connector from the battery compartment. Pull the white cord on the front battery connector to remove the batteries. Reach into the battery compartment and grasp the white cord on the other battery connector. Pull firmly to disconnect the connector and remove the second set of batteries. Hold the connector down below the top of the batteries and toward the door, otherwise the assembly will not fit. Guide the connector over the top of the batteries and press firmly to connect it to the rear connector of the battery compartment. [. . . ] Dispose of the old battery properly at an appropriate recycling facility or return it to the supplier in the packing material for the new battery. See the new battery instructions for more information. User Configuration Items Note: Setting these items requires optional software or hardware. Function Factory Default Every 14 days (336 hours) User Selectable Choices Description Service If the UPS requires service do not return it to the dealer! Follow these steps: Automatic Self-Test Every 7 days (168 hours), On Startup Only, No SelfTest Up to eight characters to define the UPS. Sets the interval at which the UPS will execute a self-test. 1. Use the Troubleshooting section of the Quick Reference Guide to eliminate common problems. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE APC SMART-UPS 2200VA LCD 230V




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual APC SMART-UPS 2200VA LCD 230V will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.