User manual APC BACK-UPS PRO 900

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual APC BACK-UPS PRO 900. We hope that this APC BACK-UPS PRO 900 user guide will be useful to you.


APC BACK-UPS PRO 900 : Download the complete user guide (188 Ko)

Manual abstract: user guide APC BACK-UPS PRO 900

Detailed instructions for use are in the User's Guide.

[. . . ] The unit is being charged whenever it is connected to utility power, whether the unit is turned ON or OFF. Install PowerChute® Personal Edition Software Place the PowerChute Personal Edition Software CD into your computer and follow the installation instructions on the screen. The Back-UPS ES provides automatic voltage regulation (AVR) by compensating for lower input power. This is done automatically, there is no visual or audio indication of this action. Status see back panel Back-UPS ES Surge Protection This outlet provides full-time protection from surges even if the Back-UPS ES is switched OFF. [. . . ] Plug your printer, fax machine, scanner, or other peripheral that does not need battery power into this outlet. Connect FAX/Modem/Phone Back-UPS ES protects a single line (2-wire) fax, modem or phone from surges when it is connected through the Back-UPS ES as shown. Wall Outlet Computer USB Port Circuit Breaker Modem/Phone/Fax AC Line Cord Status see back panel UPS Status Indicator Battery Replacement Status Indications The Back-UPS ES is shipped with battery connected. Battery replacement is a safe procedure isolated from electrical hazards. Do not replace the battery when the UPS is On Battery (amber indicator is lit). Slide the battery cover completely off of the unit. Status LED Green Amber Audible Indication None 4 beeps every 30 seconds Rapid beeping Status On Line - UPS is supplying conditioned AC power to the connected equipment. On Battery - UPS is supplying battery power to the equipment connected to the Battery outlets. Low Battery Warning - UPS is supplying battery power to the equipment connected to the Battery outlets and the battery is near exhaustion. Overloaded - Occurs when one or more of the battery powered outlets is overloaded. Power Switch The Back-UPS ES indicates operating status using a combination of visual and audible indicators. Alarm Terminates When n/a The UPS transfers back to On Line operation, or when the UPS is turned off. The UPS transfers back to On Line operation, or when the UPS is turned off. The UPS is turned off with the power switch or when the test is completed. The UPS is turned off with the power switch or the battery is replaced. The output waveform is designed for computers and computer-related equipment. Once On Battery, you should save your current work, power down your equipment, and turn the unit OFF. Once normal power is restored, you may turn the unit back ON and power your equipment. The Back-UPS ES is about to shut off due to a low battery charge condition!When the unit beeps once every second, the battery has about 2 minutes of power remaining. Allow the unit to charge by leaving it plugged into the wall at least 16 hours. Batteries also age prematurely if the Back-UPS ES is placed near excessive heat. The Status indicator is lit (amber) and the Back-UPS ES is beeping four times every 30 seconds. The Back-UPS ES is operating on battery. The Status indicator flashes Battery capacity is low (about 2 minutes of (amber) once per second and the use remaining). Battery is near the end of useful life. Specifications Model Input Voltage Frequency Brownout Transfer Over-voltage Transfer Output Battery Backup with Surge Capacity (3 outlets) Surge Only Capacity (1 outlet) Voltage - On Battery Transfer Time Protection and Filter AC Surge Protection Telephone Surge Protection EMI/RFI Filter AC Input Battery Type Typical Life Physical Net Weight Size (UPS only) Operating Temperature Storage Temperature Operating Relative Humidity Operating Elevation Order Replacement Battery BE525_RS 230 V AC Nominal 47 - 53 Hz 160 V AC, typical 280 V AC, typical 525 VA / 300 W 6 Amps (including UPS output) 230 V AC + 8% (step-approximated sine wave) 5 ms typical, 10 ms maximum Full time, 150 joules Single line (2-wire) Full time Resettable circuit breaker Sealed, maintenance-free lead acid 3 - 6 years depending on the number of discharge cycles and environmental temperature 7. 3 kg (16 lb) 12 x 28. 5 x 19. 7 cm (4. 72” (H) x 11. 2” (W) x 7. 8” (D)) 0oC to 40oC (+32oF to 104oF) -15oC to 45oC (+5oF to 113oF) 0 to 95% non-condensing 0 to 10, 000 ft (0 to 3, 000m) Replace with an APC qualified battery. Your model number can be found on the bottom of the unit. Warranty The standard warranty is 2 years from the date of purchase. APC’s standard procedure is to replace the original unit with a factory-reconditioned unit. Customers who must have the original unit back due to assigned asset tags and set depreciation schedules must declare such a need at first contact with APC Technical Support. [. . . ] APC’s standard procedure is to replace the original unit with a factory-reconditioned unit. Customers who must have the original unit back due to assigned asset tags and set depreciation schedules must declare such a need at first contact with APC Technical Support. APC will ship the replacement unit once the defective unit is received by the repair department, or cross-ship upon the provision of a valid credit card number. APC pays ground freight transportations costs back to the customer. Service 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE APC BACK-UPS PRO 900




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual APC BACK-UPS PRO 900 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.