User manual APC BACK-UPS PRO 1200VA 230V CEE 75

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual APC BACK-UPS PRO 1200VA 230V CEE 75. We hope that this APC BACK-UPS PRO 1200VA 230V CEE 75 user guide will be useful to you.


APC BACK-UPS PRO 1200VA 230V CEE 75 : Download the complete user guide (188 Ko)

Manual abstract: user guide APC BACK-UPS PRO 1200VA 230V CEE 75

Detailed instructions for use are in the User's Guide.

[. . . ] During a power outage or other utility problem (brownouts, over-voltages), these outlets are powered for a limited time by the Back-UPS ES. Once the equipment is connected to the Back-UPS ES, power on the connected equipment. Surge Protected Only Battery Powered plus Surge Protection Connect Input Power Cord Circuit Breaker (Press to Reset) Power On/Off Pushbutton Surge Protected Outlet Wall Outlet 3 Modem/Phone/Fax Back-UPS ES Status Indications and Specifications Status Visual Indication Power On LED - ON Power On LED - ON (off during beep) Audible Indication None Beeping 4 times every 30 seconds Rapid beeping (1 second intervals) Alarm Terminates When Not Applicable UPS transfers back to On Line operation, or when UPS is turned off. Not Applicable When unit is turned off or enters backup mode or passes selftest. [. . . ] The user should contact APC for service options. 4 This outlet provides protection from surges no matter if the Back-UPS is switched on or off. Plug a printer, fax machine, scanner, or other peripheral that does not need battery power during a power failure into this outlet. Troubleshooting and Battery Replacement Use the table below to solve minor Back-UPS installation or operation problems. Consult APC Online Technical Support or call APC Technical Support for assistance with problems that cannot be solved using the table below. Battery is discharged and utility power is not available at the wall outlet. Surge Protection outlet has been overloaded or the circuit breaker has "tripped". If the Back-UPS ES will not turn on, contact APC Technical Support (see APC Contact Information). Check the circuit breaker and reset the breaker by pushing it fully inward. Ensure that the fuse or circuit breaker for the wall outlet is not tripped, and that the wall switch controlling the outlet (if any) is in the ON position. Ensure that the equipment you want to stay powered during a power failure is plugged into the "Battery Powered plus Surge Protection" outlets and NOT the "Surge Protection Outlet". Make sure that the equipment plugged into the outlets of the unit are not overloading the capacity of the unit. The Back-UPS ES may require service. UPS Power On Indicator Power On/Off Switch Model Voltage / Frequency Low Voltage Transfer Input High Voltage Transfer UPS Capacity (3 battery powered outlets) Surge Capacity (all 4 outlets) Output Voltage (on battery) Frequency (on battery) Transfer Time (ms) AC Surge Protection Surge Protection Telephone Surge Protection AC Input Protection Battery Type Battery Recharge Time Average Life Span Net Weight Physical Size None BE500-AS BE525-AS The On Line indicator is lit and the Back-UPS ES is beeping four times every 30 seconds. The Back-UPS ES is using battery. The Power On indicator flashes once per second and the BackUPS ES beeps once per second at the same time. Inadequate runtime. Battery capacity is low (about 2 minutes of use remaining). 220 VAC / 47-53 Hz 180 VAC 260 VAC 500 VA / 300 Watts 525 VA / 315 Watts The battery is not fully charged. Battery is near the end of useful life. 5 Amps 220 Vrms +8/-8% 50 Hz +/- 1 Hz 8 ms typical, 10 ms max. 450 Joules Single line, 2-wire Battery Replacement Battery replacement must be performed by qualified service personnel using the following procedures: Caution: A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries: Remove watches, rings, or other metal objects. Lay the Back-UPS on a flat, stable surface with the wall mounting holes facing upward. Loosen fully, the four screws which secure the rear cover to the Back-UPS. Disconnect the red wire from the battery terminal by grasping the black portion of the wire and pull straight back from the connector. Disconnect the black wire from the battery terminal by grasping the black portion of the wire and pull straight back from the connector. [. . . ] Disconnect the black wire from the battery terminal by grasping the black portion of the wire and pull straight back from the connector. Recycle or dispose of the old battery in accordance with local requirements, or return it to APC to ensure proper recycling. Set the replacement battery in the Back-UPS with the terminals facing upward. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE APC BACK-UPS PRO 1200VA 230V CEE 75




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual APC BACK-UPS PRO 1200VA 230V CEE 75 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.