If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual APC BACK-UPS CS 650VA 230V. We hope that this APC BACK-UPS CS 650VA 230V user guide will be useful to you.
Manual abstract: user guide APC BACK-UPS CS 650VA 230V
Detailed instructions for use are in the User's Guide.
[. . . ] ON LINE - is lit whenever utility power is supplied to power the equipment connected to the Back-UPS. ON BATT - the On Battery symbol is lit whenever battery backup power is used to power equipment connected to the Back-UPS. Four Beeps Every 30 Seconds - this alarm sounds whenever the Back-UPS is running on battery (ON BATT). Continuous Beeping - this alarm sounds whenever a low battery condition occurs, and battery run-time is very low. [. . . ] System Faults - when a fault occurs, this symbol and the fault number (F01 - F09) will flash off and on. Mute mode - the audible alarm (beeper) can be muted (turned off), which is indicated by a line through the beeper symbol. Sensitivity mode - this allows you to go into sensitivity programming mode, and using the DISPLAY button you can select the LO, MID or HIGH sensitivity range. Full Time Display mode - this mode allows you to set the LCD to full time display mode using the DISPLAY button. This mode is covered in greater detail on Page 2.
Reset switch - this switch is located on the rear of the Back-UPS, just above the fans, as shown in the figure in Step 4. 990-4991
ESTIMATED RUN TIME IN MINUTES
Battery Charge
IN OUT
V kW Hz
%
System Faults
AVR
SEE MANUAL
System Status
DISPLAY HOLD TO MUTE
Continuous tone - this alarm sounds whenever the battery backup outputs are overloaded. Overload mode is covered in greater detail on Page 2.
Replace battery - this is lit whenever the battery is near the end of its useful life, or if the battery is not connected. A battery nearing the end of its life should be replaced.
LOAD
ON LINE
LOW
ON BATT
SENSITIVITY
ESTIMATED RUN TIME IN MINUTES
IN OUT
V kW Hz
%
AVR
SEE MANUAL
DISPLAY HOLD TO MUTE
Power ON/OFF switch - is used to turn input power on and off. It is also used to initiate self-test, to go into Sensitivity mode, and it is used with the DISPLAY button to reset the Event Counter.
Chirps for 1 Minute every 5 hours - this alarm sounds whenever the battery fails the automatic diagnostic test.
ON-LINE MODE Display Selection
When you are in ON-LINE mode, and press the DISPLAY button, you will rotate through the following seven groups of displays and messages. When you press the DISPLAY button the first time, the LCD is back lit, and the input voltage (IN) default screen is displayed, in this example 110 V is displayed. When you press the DISPLAY button a second time, the power EVENT counter is displayed, as shown below. Once you have selected the desired display mode, continue with normal operations.
TROUBLESHOOTING
Problem
Back-UPS will not switch on.
SPECIFICATIONS
Possible Cause
Back-UPS is not connected to the AC power source. For the BR1300LCD, BR1500LCD, BX1300LCD and BX1500LCD order part APCRBC109. Please recycle spent battery cartridges.
Internal battery is not connected. The UPS's plug has partially pulled out of the wall outlet, the wall outlet was turned off, or its circuit breaker tripped. Utility input voltage is out of range, frequency is out of range, or the waveform is distorted. Back-UPS battery cartridge discharged due to a recent power outage, and has not had time to recharge. System Fault indicator is on and all other front panel indicators are flashing. Connected equipment is drawing more power than the Back-UPS can provide. Internal UPS fault.
WARRANTY
The standard warranty is three (3) years from the date of purchase. APC's standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at first contact with an APC Technical Support representative. [. . . ] Be prepared to troubleshoot the problem with an APC Technical Support representative. If this is not successful, APC will issue a Return Merchandise Authorization (RMA) number and a shipping address.
CONTACT INFORMATION
Technical Support Internet USA / Canada Mexico Worldwide http://www. apc. com/support http://www. apc. com 1. 800. 800. 4272 292. 0253 / 292. 0255 +1. 401. 789. 5735
LIMITED WARRANTY
TRANSFER VOLTAGE and SENSITIVITY ADJUSTMENT
In situations where the Back-UPS or connected equipment appears too sensitive to the input voltage, it may be necessary to adjust the transfer voltage. Plug the Back-UPS into the utility power source, but do not turn the unit on. The Back-UPS will be in standby mode (there are no indicators lit). Press and hold the front panel on/off switch in for 10 seconds, until all the indicators on the Back-UPS flash to acknowledge it has entered sensitivity programming mode. [. . . ]