User manual APC BACK-UPS ES 525

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual APC BACK-UPS ES 525. We hope that this APC BACK-UPS ES 525 user guide will be useful to you.


APC BACK-UPS ES 525 : Download the complete user guide (203 Ko)

Manual abstract: user guide APC BACK-UPS ES 525

Detailed instructions for use are in the User's Guide.

[. . . ] The unit charges whenever it is connected to utility power and is switched on. 2 IMPORTANT: It is recommended that you DO NOT turn on your monitor until the UPS has been powered on and has completed self-test (approximately 16 seconds). Back-UPS 500 ES Back-UPS 525 ES Connect Communication Cable and Install Software (optional - Back-UPS ES 525 only) The included cable and software (Back-UPS ES 525 only) provide automatic file saving and shutdown of the operating system in the event of a sustained power outage. Place the PowerChute plus® CD-ROM into your computer and follow installation instructions on the screen. [. . . ] Self-Test in progress Self-Test failed (need service) No power available at the Surge Protection outlet. Connected equipment loses power. Power On LED - Flashing Power On LED - OFF Constant tone Power On LED - OFF Beeping once every 4 seconds PowerChute plus software has performed a shutdown due to a power failure. The Back-UPS ES has exhausted its available battery power. Power On LED - On Power On LED - flashing 2 times per second None Short beeping 2 times every 2 seconds for 1 minute repeated every 5 hours The Back-UPS ES can only operate on battery power for a limited amount of time. The unit will eventually turn off when the available battery power has been used. Allow the unit to recharge for 16 hours before continuing use of the unit. The output waveform is designed for computers and computerrelated equipment. Contact APC Technical Support for further troubleshooting (see APC Contact Information). Once On Battery, you should save your current work, power down your equipment, and turn the unit OFF. Once normal power is restored, you may turn the unit back ON and power your equipment. The Back-UPS ES is about to shut off due to a low battery charge condition!When the unit beeps once every second, the battery has about 2 minutes of power remaining. Allow the unit to charge by leaving it plugged into the wall at least 16 hours. [. . . ] Plug the Back-UPS into the wall outlet, press the Power pushbutton on the Back-UPS to turn it on, and allow the battery to charge for 16 hours. Plug equipment to be protected into the Back-UPS and resume normal operation. Circuit Breaker Switch Sealed Lead Acid 10-12 Hours 2-4 Years 3. 6 kg (7. 9 lb) 29. 79 cm x 18. 3 cm x 8. 49 cm (11. 73 in x 7. 2 in x 3. 34 in) Service 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE APC BACK-UPS ES 525




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual APC BACK-UPS ES 525 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.