User manual AMX VIEWSTAT INSTALLATION GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX VIEWSTAT INSTALLATION GUIDE. We hope that this AMX VIEWSTAT INSTALLATION GUIDE user guide will be useful to you.


AMX VIEWSTAT INSTALLATION GUIDE : Download the complete user guide (248 Ko)

Manual abstract: user guide AMX VIEWSTAT INSTALLATION GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] The ViewStat is compatible with any 24volt controlled HVAC system, as well as millivolt systems. This manual describes how the ViewStat connects to several different types. See the ViewStat Communicating Thermostat Instruction Manual (available online at www. amx. com) for details. [. . . ] To connect multiple ViewStats to a NetLinx system, use a NetLinx Hub (NXC-NH) to add additional ICSNet ports to the system. Connect the RJ-45 jack on the VST to an available ICSNet jack. PHASTLink RJ-45 Pinout Information (EIA/TIA 568 A) Pin 1 2 3 4 5 6 7 8 Wire Color White/Green Green White/Orange Blue White/Blue Orange White/Brown Brown Polarity + + + + Function Transmit Transmit Mic Ground 12 VDC Mic Receive Receive T IA 5 6 8 A Connecting to a Landmark Control System To connect a single VST to a Landmark control system, use PhastLink cabling to connect the RJ-45 jack on the VST to any available PhastLink jack on the Landmark Master. The maximum cabling distance between the VST and Controller is 1, 000 ft. To connect multiple ViewStats to a Landmark system, use a Landmark Hub (PLHRPT) to add additional PhastLink ports to the system. Connect the RJ-45 jack on the VST to an available PhastLink jack. Connecting the ViewStat to the HVAC System Before connecting the VST to the HVAC system, install the 24 VAC Suppression Ferrite, to eliminate any potential noise problems. Installing the 24 VAC Suppression Ferrite Before connecting the 24 VAC power supply cable to the HVAC system, install the 24 VAC Suppression Ferrite (provided), as described below (no tools required - see FIG. 3): jumper from RC to RH Common (black) from 24 VAC HVAC System 1. Loop the cable around and pass it through the ferrite bead again. 3. Gently pull the cable to eliminate excess slack. Power (red) from 24 VAC HVAC System FIG. 3 Installing the 24 VAC Suppression Ferrite Setting the DIP Switch Set the DIP switch located on the thermostat circuit board (FIG. 4) according to the application needs (see the DIP Switch Settings table below for details). MASTER cutout FOSSIL OFF ON MULTI H/C SERVANT ELECTRIC SINGLE HT. PUMP from MiniVerter FIG. 5 ViewStat base with Communication, Power and Equipment terminals ViewStat base (top view) 1 Insert the MiniVerter (connector-side down) into the guide slots inside the mounting bracket. 2 Slide the MiniVerter into locking position in the bracket. FIG. 4 Setting the DIP Switch The following table shows what each switch corresponds to depending on position. Switch one should be set in the "OFF Servant" position unless you plan to broadcast readings from remote temperature sensors to other thermostats in the system when there is no control system in place. mounting bracket 3 Snap into place MiniVerter FIG. With the connector-side of the MiniVerter seated in the guide-slots, gently press the opposite side of the MiniVerter in and down, to snap it into its locked position on the mounting bracket. DIP Switch Settings Application Single Stage Furnace & AC Two Stage Furnace & Two Stage AC Roof Top Unit (Two Stage Heat & Two Stage Cool) Boiler with AC (Two Transformers) Single Stage Heat Pump Two Multi-stage Heat Pump First Stage Radiant Floor Heat, Second Stage Furnace One Stage of Cooling Switch #1 Servant Servant Servant Servant Servant Servant Servant Switch #2 Fossil Fossil Fossil Fossil Electric Electric Fossil Switch #3 Single Multi Multi Single Single Multi Multi Switch #4 H/C H/C H/C H/C HT. Pump H/C Connecting the ViewStat to the HVAC System Warning! 120 volts may cause serious injury from electrical shock. Disconnect electrical power to the HVAC system before starting installation. [. . . ] 6). Maximum Cable Distances Maximum Cable Distances Between the VST and NetLinx or LandMark Controller: Between support module and VST: Max. cumulative cable length between multiple support modules and VST: Between support module and remote sensor: 1000' (304. 8m) 1000' (304. 8m) 1000' (304. 8m) 300' (91. 44m) Additional Information Refer to the ViewStat Communicating Thermostat Instruction Manual (available online at www. amx. com) for additional information and details on the VST and related devices, including: · · · · Product Specifications for the VST and Support Modules Configuration, installation and wiring of the VST, Support Modules and Remote Temperature Sensors. HVAC system wiring diagrams. AMX Corporation reserves the right to alter specifications without notice at any time. For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX VIEWSTAT INSTALLATION GUIDE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX VIEWSTAT INSTALLATION GUIDE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.