User manual AMX TOUCH PANEL INTERFACE 4

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX TOUCH PANEL INTERFACE 4. We hope that this AMX TOUCH PANEL INTERFACE 4 user guide will be useful to you.


AMX TOUCH PANEL INTERFACE 4 : Download the complete user guide (2367 Ko)

Manual abstract: user guide AMX TOUCH PANEL INTERFACE 4

Detailed instructions for use are in the User's Guide.

[. . . ] Operation/Reference Guide NXP-TPI/4 NetLinx Touch Panel Interface 4 Firmware version G4 Touch Panels Document ID: 060-004-2602 Initial Release: / Last Revised: 06/19/2006 AMX Limited Warranty and Disclaimer AMX warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX, with the following exceptions: · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year. AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long as the AMX Lighting products are under warranty. AMX does guarantee the control of dimmable loads that are properly connected to our lighting products. [. . . ] Time Date Refresh/Set: This section provides you with two options: · The Get Time/Date button retrieves the Time and Date information from the Master. · The Set Time/Date button sets the Master to retain and save any time/date modifications made on the Time and Date Setup page. 60 NXP-TPI/4 NetLinx Touch Panel Interface Firmware Pages and Descriptions Time & Date Setup Page Elements (Cont. ) Time Display fields: Date Display fields: Set Date/Time: · These fields display the time in three formats: STANDARD, STANDARD AM/PM, and 24 HOUR. · These fields display the calendar date information in several different formats. This section provides a user with both UP/DN arrow buttons to alter the Master's calendar date and time. · Select the Year field and use the UP/DN buttons to alter the year value (range = 2000 - 2037). · Select the Month field and use the UP/DN buttons to alter the month value (range = 1 - 12). · Select the Day field and use the UP/DN buttons to alter the day value (range = 1 - 31). · Select the Hour field and use the UP/DN buttons to alter the hour value (24-hour military). · Select the Minute field and use the UP/DN buttons to alter the minute value (range = 0 - 59). · Select the Second field and use the UP/DN buttons to alter the second value (range = 0 - 59). The TPI/4 does not have an on-board clock. This page both receives and sets the time/date of the NetLinx Master. Volume Page The Volume page (FIG. 44) (accessed by pressing the Audio Adjustments button on the Setup page) allows you to adjust the master volume parameters and default panel sounds on the TPI/4. FIG. 44 Volume configuration page The elements of the Volume page are described in the table below: Volume Page Elements Exit: Connection Status icon: Saves the changes and returns you to the previously active touch panel page. This visual display of the connection status allows the user to have a current update of the TPI/4's connection status regardless of what page is currently active. · A Lock only appears on the icon if the TPI/4 has established a connection with a currently secured target Master (requiring a username and password). NXP-TPI/4 NetLinx Touch Panel Interface 61 Firmware Pages and Descriptions Volume Page Elements (Cont. ) Panel Volume: This section allows you to adjust the current sound level on the unit's internal speaker: · Use the UP/DN buttons to adjust the volume output on the internal speakers (range = 0 - 100). · The Internal Sound Level bargraph indicates the current sound level. · The Play Test button plays a test WAV/MP3 file over the internal speakers. Default Panel Sounds: Sets the unit to play either the default Button Hit sound (when you touch an active button) and/or the default Button Miss sound (when you touch a non-active button or any area outside of the active button). Supported sampling rates for WAV The following is a listing of supported sampling rates associated for WAV files played on this G4 unit. Some WAV files currently played on other devices may not work on this unit. The supported sampling rates for WAV files are: Supported WAV Sampling Rates · 48000 Hz · 44100 Hz · 32000 Hz · 24000 Hz · 22050 Hz · 16000 Hz · 12000 Hz · 11025 Hz · 8000 Hz Protected Setup Page This button opens the Protected Setup page which centers around the properties used by the panel to properly communicate with the NetLinx Master. Refer to the Protected Setup Navigation Buttons section on page 68 for more detailed information. Video Adjustment Slide-Out Option Bar Pressing the on-screen Video Adjustment button causes an option bar to slide outwards from the Navigation buttons (FIG. This option bar provides you with the ability to select/adjust the properties for the TP4 card connected to the selected slot number and displays the corresponding Adjustment page. [. . . ] When data overflows from a numerical field, the overflow value is added to the previous field on the chain, if the overflow character was specified. In the above example, if the overflow flag was set, the first example will place the "1" into the previous logical field and the second example will place "12" in the previous logical field. If the overflow filed already contains a value, the new value will be inserted to the right of the current characters and the overflow field will be evaluated. Overflow continues to work until a filed with no overflow value is set or there are no more fields left (i. e. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX TOUCH PANEL INTERFACE 4




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX TOUCH PANEL INTERFACE 4 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.