If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX RDD-DM6 6-CHANNEL INTEGRATED DIMMER MODULE. We hope that this AMX RDD-DM6 6-CHANNEL INTEGRATED DIMMER MODULE user guide will be useful to you.
Manual abstract: user guide AMX RDD-DM6 6-CHANNEL INTEGRATED DIMMER MODULE
Detailed instructions for use are in the User's Guide.
[. . . ] Installation Sheet
RDD-DM6 6-Channel Integrated Dimmer Module 120, 240, 277 VAC
The RDD-DM6 Six-Channel Integrated Dimmer Module controls up to six dimmed channels with six onboard 10 A dimmers. [. . . ] 2 Connecting AXlink
Connecting PROlink:
Connect the orange 4-pin captive-wire PROlink connector from the RDD-DM6 to a PRO-DP8 PROlink wall panel.
PRO-DP8 +12 PR+ PRGND Pack 1 Pack 2 +12 PR+ PRGND
FIG. 1 RDD-DM6 6-channel Integrated Dimmer Module
RDD-DM6 UL and C-UL Ratings (per circuit)
Input · 120, 240, 277 VAC, single phase, 3-wire, 50/60 Hz, 2400 W, one feed · 120, 240, 277 VAC, single phase, 4-wire, 50/60 Hz, 4800 W, two feed Output · · · · 1200 W max. total, all six channels on with dual 2400 W feeds Feed circuit #1 goes to dimmer 1, 3, and 5; feed circuit #2 goes to dimmer 2, 4 and 6 Incandescent Low-voltage Neon, cold-cathode Motors Fans
FIG. 3 Connecting PROlink
Line-in Connections:
Dual 2400 W Inputs
Using two feeds for line 1 and line 2 provides two, 2400 W inputs.
Suggested Switched Loads
· · · · ·
Bridging line 1 and line 2 provides a single 2400 W input.
20 A
Bridged 2400 W Input
FIG. 4 Line-in Connections
Connecting Dry Closures:
Use the 8 (+ common) dry closures with a WPD8 eight-button wall panel.
Setting AXlink and PROlink Address Numbers:
AXlink Address PROlink Address Test Each contact (1 - 8) is preprogrammed with a default preset. Refer to the AMX Lighting Control System instruction manual for details on dry closure default presets and recording new presets. Use the PROlink DIP switch to set the PROlink address number for the RDD-DM6 (1-10). Pin 8 on the PROlink DIP switch is a test switch that turns all circuits on to full.
1
2
3
4
5
6
7
8 COM
FIG. [. . . ] 3000 research drive, richardson, TX 75082 USA · 469. 624. 8000 · 800. 222. 0193 · fax 469. 624. 7153 · technical support 800. 932. 6993 [. . . ]