User manual AMX RDD-DM6 6-CHANNEL INTEGRATED DIMMER MODULE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX RDD-DM6 6-CHANNEL INTEGRATED DIMMER MODULE. We hope that this AMX RDD-DM6 6-CHANNEL INTEGRATED DIMMER MODULE user guide will be useful to you.


AMX RDD-DM6 6-CHANNEL INTEGRATED DIMMER MODULE : Download the complete user guide (303 Ko)

Manual abstract: user guide AMX RDD-DM6 6-CHANNEL INTEGRATED DIMMER MODULE

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Sheet RDD-DM6 6-Channel Integrated Dimmer Module 120, 240, 277 VAC The RDD-DM6 Six-Channel Integrated Dimmer Module controls up to six dimmed channels with six onboard 10 A dimmers. [. . . ] 2 Connecting AXlink Connecting PROlink: Connect the orange 4-pin captive-wire PROlink connector from the RDD-DM6 to a PRO-DP8 PROlink wall panel. PRO-DP8 +12 PR+ PRGND Pack 1 Pack 2 +12 PR+ PRGND FIG. 1 RDD-DM6 6-channel Integrated Dimmer Module RDD-DM6 UL and C-UL Ratings (per circuit) Input · 120, 240, 277 VAC, single phase, 3-wire, 50/60 Hz, 2400 W, one feed · 120, 240, 277 VAC, single phase, 4-wire, 50/60 Hz, 4800 W, two feed Output · · · · 1200 W max. total, all six channels on with dual 2400 W feeds Feed circuit #1 goes to dimmer 1, 3, and 5; feed circuit #2 goes to dimmer 2, 4 and 6 Incandescent Low-voltage Neon, cold-cathode Motors Fans FIG. 3 Connecting PROlink Line-in Connections: Dual 2400 W Inputs Using two feeds for line 1 and line 2 provides two, 2400 W inputs. Suggested Switched Loads · · · · · Bridging line 1 and line 2 provides a single 2400 W input. 20 A Bridged 2400 W Input FIG. 4 Line-in Connections Connecting Dry Closures: Use the 8 (+ common) dry closures with a WPD8 eight-button wall panel. Setting AXlink and PROlink Address Numbers: AXlink Address PROlink Address Test Each contact (1 - 8) is preprogrammed with a default preset. Refer to the AMX Lighting Control System instruction manual for details on dry closure default presets and recording new presets. Use the PROlink DIP switch to set the PROlink address number for the RDD-DM6 (1-10). Pin 8 on the PROlink DIP switch is a test switch that turns all circuits on to full. 1 2 3 4 5 6 7 8 COM FIG. [. . . ] 3000 research drive, richardson, TX 75082 USA · 469. 624. 8000 · 800. 222. 0193 · fax 469. 624. 7153 · technical support 800. 932. 6993 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX RDD-DM6 6-CHANNEL INTEGRATED DIMMER MODULE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX RDD-DM6 6-CHANNEL INTEGRATED DIMMER MODULE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.