If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX RADIA DIMMER ENCLOSURES WITH BREAKERS. We hope that this AMX RADIA DIMMER ENCLOSURES WITH BREAKERS user guide will be useful to you.
Manual abstract: user guide AMX RADIA DIMMER ENCLOSURES WITH BREAKERS
Detailed instructions for use are in the User's Guide.
[. . . ] Installation Sheet
RDA-ENC6B and ENC12B
The RDA-ENC6B (FG606-13) and RDA-ENC12B (FG606-14) enclosures provide secure mounting for all AMX Lighting and PROlink controllers, and lighting modules. [. . . ] Maintain 12" (304. 88 mm) minimum clearance above and below the enclosure. Install only UL approved modules (see the UL Number Cross Reference to AMX Lighting ID table on page 2). (7. 94 kg)
Configuration for right and left mounting brackets for all Radia enclosures.
A to B Top slot B to C
Maximum mounting screw size: #12 Bottom slot
Enclosure Weights:
· · FIG. 2):
RDA-ENC6B: · A to B = 16. 0" (406. 4 mm) · B to C = 22. 88" (581. 2 mm) RDA-ENC12B: · · A to B = 16. 0" (406. 4 mm) B to C = 22. 88" (581. 2 mm)
Specifications
· · · · · · · · · Maximum input wire #1/0 AWG (50mm²) Maximum line input is 140 A (per enclosure ) Torque input wire to 44 in-lbs. (5. 0 N/m) Wire stripping length: 0. 67 inches (17 mm) Input 1 feeds channels 1, 4, 7, and 10 Input 2a feeds channels 5 and 11 Input 2b feeds channels 2 and 8 Input 3 feeds channels 3, 6, 9, and 12 Breakers are UL 489 listed 10, 000 AIC, 100% Switching Duty, Hydraulic-Magnetic
Radia enclosures must be mounted on a vertical surface with a minimum of 12" (304. 8 mm) clearance above and below the enclosure.
The following section cross references the UL ID module numbers and AMX Lighting module IDs. The modules identified are the only ones that can be used in the RDAENC6B and RDA-ENC12B enclosures.
UL Number Cross Reference to AMX Lighting ID
UL ID AMX ID UL ID AMX ID UL ID AMX ID 28-10100 RDC-DC/120 28-10110 RDC-DC/240 28-10120 RDC-DC/277 28-10130 RDC-PDC/120 28-10200 RDM-INC 28-10210 RDM-2INC 28-10220 RDM-INC50 28-10230 RDM-ZC, RDM-2ZC 28-10300 RDM-MR60 28-10310 RDM-MDM 28-10340 RDA-CHK 28-10350 RDM-FDB RDM-2FDB RDM-3FDB RDM-HFDB 28-10360 RDM-DPSM
UL Number Cross Reference to AMX Lighting ID (Cont. )
UL ID AMX ID UL ID AMX ID UL ID AMX ID 28-10140 RDD-DM6/120 28-10260 RDM-SWM, RDM-2SWM, RDM-3SWM 28-10270 RDM-HSW, RDM-2HSW, RDM-3HSW 28-10370 RDM-DC, RDM-2DC, RDM-3DC RDM-HDC
28-10150 RDD-DM6/240
28-10160 RDD-DM6/277 28-10170 RDA-PSM/120
28-10133 RDC-PDC/240
28-10240 RDM-ZC50
Lighting Application Drawings
Note:
LINE INPUTS: 140 A MAX PER ENCLOSURE
Use 75° C copper conductors only. [. . . ] 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 · 800. 222. 0193 · fax 469. 624. 7153 · technical support 800. 932. 6993 · www. amx. com