User manual AMX PRO-DP16 DECOR PROLINK FLUSH MOUNT KEYPAD PANEL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX PRO-DP16 DECOR PROLINK FLUSH MOUNT KEYPAD PANEL. We hope that this AMX PRO-DP16 DECOR PROLINK FLUSH MOUNT KEYPAD PANEL user guide will be useful to you.


AMX PRO-DP16 DECOR PROLINK FLUSH MOUNT KEYPAD PANEL : Download the complete user guide (483 Ko)

Manual abstract: user guide AMX PRO-DP16 DECOR PROLINK FLUSH MOUNT KEYPAD PANEL

Detailed instructions for use are in the User's Guide.

[. . . ] instruction manual PRO-DP16 Decor 16-Button Wall Panel Lighting Control AMX Limited Warranty and Disclaimer AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year. AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long as the AMX Lighting products are under warranty. AMX Corporation does guarantee the control of dimmable loads that are properly connected to our lighting products. [. . . ] Avoid connecting more than three PRO-DPs to a Pack without a separate power supply for the panels (see the Using a PROlink 4-pin connector with an external 12 VDC power supply section on page 9 for details). Preparing captive wires You will need a wire stripper, and flat-blade screwdriver to prepare and connect the captive wires. Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types described in this section. Turn the flat-head screws clockwise to secure the wires in the connector. Do not over-torque the screws; doing so can bend the seating pins and damage the connector. Using a PROlink 4-pin connector for data and power These steps describe how to connect the dimmer Pack's PROlink connector to the PROlink connector (male) on the rear panel of the PRO-DP16 for data and 12 VDC power. Check for short circuits and continuity before connecting panels to the PROlink connector on the dimmer Pack. 1. The captive-wire terminal on the PRO-DP16 is wired to an orange captive-wire terminal on the Pack. Insert each wire into the appropriate opening on the connector, according to the wiring diagram shown in FIG. 3. 8 PRO-DP16 Decor 16-Button PROlink Wall Panel Wiring and Installation PRO-DP16 +12 PR+ PRGND Pack 1 Pack 2 +12 PR+ PRGND FIG. 3 Wiring diagram for connecting the PRO-DP16 to a single dimmer control card Additional panels can be daisy-chained or connected directly to the Pack's terminal. Use a 12 VDC power supply when more than three PRO-DP16 panels are used with one Pack. Refer to the Using a PROlink 4-pin connector with an external 12 VDC power supply section on page 9 for more information. Verify PROlink wiring connections are correct before applying power to the Pack. 2. Connect the PROlink connector to the panel (see the Preparing captive wires section on page 8). If the green LED flashes once every 2 seconds, the panel is communicating properly with the Pack. If the LED is on and not flashing, disconnect the PROlink connector and recheck all PROlink connections; reconnect the PROlink connector to the panel and verify the LED is flashing once every 2 seconds. Test to see if the panel recalls a Preset or ramps dimmers (if test fails, refer to the Troubleshooting section on page 12). Using a PROlink 4-pin connector with an external 12 VDC power supply Use a 12 VDC power supply when the distance between the Pack and PRO-DP16 exceeds 1, 000 feet (304. 8 m), or when more than three PRO-DP16 panels are used with one Pack. Make sure to connect only the GND wire on the PROlink connector when using a 12 VDC power supply. While AMX recommends installing a maximum of three PRO-DP16 panels per Pack, the actual maximum number of panels allowed per Pack is a function of power and distance between the two. Connect the Pack's PROlink connector to the PROlink connector on the rear panel of the PRODP16, as described in the following steps. The captive-wire terminal on PRO-DP16 is wired to an orange captive-wire terminal on the Pack. Insert each wire into the appropriate opening on the connector, according to the wiring diagram shown in FIG. 4. PRO-DP16 Decor 16-Button PROlink Wall Panel 9 Wiring and Installation 12 VDC power supply PWR (+) GND (-) PRO-DP16 +12 PR+ PRGND Pack 1 Pack 2 +12 PR+ PRGND FIG. 4 PROlink wiring diagram using an external 12 VDC power supply Do not connect the PWR wire to the PROlink connector's PWR (+) terminal on the control system side of the connector. 2. Connect the PROlink connector to the panel (see the Preparing captive wires section on page 8). [. . . ] These curve plots are to be used as a relative guide to determining optimum performance. Actual field performance and measurements will be similar but not equal. Note the Pack number set on the SW2 DIP switch for the desired dimmer Pack you will be working with. See the Assigning Pack numbers on the dimmer control cards section on page 7 for details. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX PRO-DP16 DECOR PROLINK FLUSH MOUNT KEYPAD PANEL




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX PRO-DP16 DECOR PROLINK FLUSH MOUNT KEYPAD PANEL will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.