User manual AMX IRIS IRSERIAL DATA CAPTURE DEVICE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX IRIS IRSERIAL DATA CAPTURE DEVICE. We hope that this AMX IRIS IRSERIAL DATA CAPTURE DEVICE user guide will be useful to you.


AMX IRIS IRSERIAL DATA CAPTURE DEVICE : Download the complete user guide (258 Ko)

Manual abstract: user guide AMX IRIS IRSERIAL DATA CAPTURE DEVICE

Detailed instructions for use are in the User's Guide.

[. . . ] This limitation of liability, however, will not apply to claims for personal injury. Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of the Limited Warranty may not apply. [. . . ] (2-digit) Red 7-segment alphanumeric display that shows the capture mode and operating status. Increments the alphanumeric display by one and lights the red LED inside the pushbutton. Decrements the display by one and lights the red LED inside the pushbutton. Transmits captured HC functions to a PC running the IRLIB software program. The red LED inside the pushbutton lights when valid HC functions are ready to send. Control ports Enclosure Includes · IR sensor to receive IR codes; IR serial input for wired IR codes. Metal with black matte finish · Large, 2-digit status LED · Adjustable RS-232 port (300 - 9600 baud) · 12 VAC power supply · IRLIB software for IBM-compatible computers 12 VDC @ 160 mA max. 1. 51" x 5. 55" x 5. 45" (3. 84 cm x 14. 10 cm x 13. 84 cm) 18. 2 oz (518. 2 g) Rear Panel Components: 12 VDC/12 VAC connector 8-pin data connector RS-232 connectors IRIS Infrared/Serial Data Capture Unit 1 Product Information IR window SIGNAL LED Alphanumeric display UP button DOWN button SIGNAL IR READY VERIFY UP DOWN SEND READY LED VERIFY LED SEND button 12V IRE IN WIRED IN 12 OUT RS-232 5 RS-232 12 V connector 8-pin data connector RS-232 6-pin RJ-11 connector RS-232 DB-9 connector FIG. 1 IRIS front and rear views 2 IRIS Infrared/Serial Data Capture Unit Installation Installation Capturing HC Functions The two modes you can use to capture HC functions are default and special function. You use default mode, which is automatically set when you connect power to the IRIS unit, to capture the majority of HC functions. Before capturing HC functions, make sure the baud rate in the IRIS unit is set properly, and connected to a PC running the IRLIB Library Management Program. Refer to the IRLIB Library Management Program instruction manual to store captured HC functions. Default Mode Settings Default Baud P3 P4 P5 P6 P7 P8 Setting 9600 off on off on on off Capturing HC functions in default mode To capture HC functions in default mode: 1. Make a list of the name and sequence of the HC functions you want to capture. The standard order for HC functions is listed in the HC IR Functions section on page 6. Connect the RS-232 cable to the DB-9 connector on the IRIS unit and the RS-232 port on your PC, as shown in the Cables and Adapters section on page 6. Refer to the Baud Rate Settings section on page 5 to set the baud rate. Then, connect the 12 VDC or 12 VAC power supply to the 12 VDC connector on the IRIS unit. Hold the HC device approximately 3-inches away from the IR capture window. The [ ] briefly appears in the display to indicate the HC function is captured. The LED will not light if P4 mode is active; refer to the Display Characters and P Modes table on page 4 for further information. Hold the HC device approximately 3-inches away from the IR capture window. [. . . ] HC IR Functions (Standard Order) Function 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Description Play > Stop [ ] Pause | | or still Ffwd >> (AMS/skip track/chapter) Rewind << (AMS/skip track/chapter) Search fwd >>| (AMS/scan) Search rev |<< (AMS/scan) Record Power or on/off '0' or '10' '1' (channel digits or tracks for CD) '2' '3' '4' Function 22 23 24 25 26 27 28 29 30 31 32 33 34 35 Description Channel up or + Channel down or Volume up or + Volume down or Mute On (power typically) Off (power typically) TV/Video or TV/VCR or TV/LDP (one button source selection) TV Video1, Line A, VCR1, VDP, or input + Video2, Line B, VCR2, or input Video3 RGB1 or Tape1 RGB2 or Tape2 6 IRIS Infrared/Serial Data Capture Unit Installation HC IR Functions (Standard Order) (Cont. ) Function 15 16 17 18 19 20 21 Description '5' '6' '7' '8' '9' '+10' or '+100' Enter (used in conjunction with number typically) Function 36 37 38 39 40 41 42 Description CD Tuner Phono Aux AM/FM Play < (play reverse) A/B IRIS Infrared/Serial Data Capture Unit 7 Installation 8 IRIS Infrared/Serial Data Capture Unit Troubleshooting Troubleshooting This section provides product solutions to common problems. E1 or ER messages The Er/E1 message appears when there is a communication problem with the PC and not an error in capturing the IR functions. E1 or Er Messages Problem A Hand Control can't seem to capture the codes. The AXB-IRIS is able to verify the codes, but when the Send Command is pressed, an Er appears on the unit's display. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX IRIS IRSERIAL DATA CAPTURE DEVICE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX IRIS IRSERIAL DATA CAPTURE DEVICE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.