If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX AXP-CPI16 CUSTOM PANEL INTERFACE BOARD (16 BUTTONS). We hope that this AMX AXP-CPI16 CUSTOM PANEL INTERFACE BOARD (16 BUTTONS) user guide will be useful to you.
Manual abstract: user guide AMX AXP-CPI16 CUSTOM PANEL INTERFACE BOARD (16 BUTTONS)
Detailed instructions for use are in the User's Guide.
[. . . ] AMX is not liable for any damages caused by its products or for the failure of its products to perform. This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX is not liable for any claim made by a third party or by an AMX Dealer for a third party. This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim (including negligence and strict product liability), a contract claim, or any other claim. [. . . ] 6
Preparing/connecting captive wires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Connecting the Two 20-pin Headers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Switch Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Connecting the AXlink Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Testing the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
AXP-CPI16 System Worksheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
AXP-CPI16 16-Channel Custom Panel Interface
i
Table of Contents
ii
AXP-CPI16 16-Channel Custom Panel Interface
Product Information
Product Information
The AMX AXP-CPI16 16 Channel Custom Panel Interface Board (FIG. 1) simplifies the process of creating custom control panels for Axcess systems. Providing contact closure inputs and feedback outputs for up to 16 buttons, the miniature PC board contains a 20-pin header for ribbon cable installation or for direct mounting to a printed circuit board.
AXlink Connector Pin 1 20-Pin Header P3 Connect this side to the ribbon cable
Pin 1
Device DIP Switch
AXlink Status LED -Pin Header P2 onnect this side to the ribbon cable FIG. 1 AXP-CPI16 components Connect this side to the PC board
Specifications
The following table lists product specifications for the AXP-CPI16.
AXP-CPI16 Specifications
Dimensions (HWD) Power Inputs Outputs 2. 75" x 1. 75" x 0. 062" (69. 90 mm x 44. 50 mm x 1. 557 mm) · Input voltage: 12 VDC (nominal) · Current draw: 25mA 16 closure inputs with a common ground (GND) 16 open-collector outputs, acting as switch to ground, up to 100 mA DC each for: · Board is not to supply more than 750 mA of +12V total. · Small incandescent lamps · LED indicators - with series resistor (1K for 12 VDC) · Relays - with DC coil AXlink Connector Headers A 4-pin (male) connector attached to a four-wire cable which sends control data from the Axcess CardFrame to the AXP-CPI16. Two 20-pin headers included for ribbon cables (up to 100 feet each) or for mounting directly to a PC board.
AXP-CPI16 16-Channel Custom Panel Interface
1
Product Information
AXP-CPI16 Specifications (Cont. )
AXlink Status LED Indicates AXlink communication status as follows: · One blink per second communication is functioning. · Two blinks per second devices specified in the master program do not match the specified devices found. · Three blinks per second indicate an AXlink communication error. · Full-on indicates there is no AXlink control or activity (but power is on), or the Axcess program is not loaded. Two 3-foot (91. 4 cm) ribbon cables each with a female 20-pin header.
2
AXP-CPI16 16-Channel Custom Panel Interface
Product Information
OFF OFF ON ON 12345 678
AXP-CPI16 16-Channel Custom Panel Interface
3
Product Information
4
AXP-CPI16 16-Channel Custom Panel Interface
Installation
Installation
Mounting Dimensions
B B A A A C C AXlink AXlink AXP GND PWR AXP AXM GND
LH
L J
A
P1
PWR AXM
P1
12 12
P3 P3
Top View
D D
E E
Top View (Component Side)
(Component Side)
19 20 19 20
MM
2 1 F F
P2 P2
20 20 19 19
J G G K K min min
H
FIG. 1 AXP-CPI16 mounting dimensions
Mounting Dimensions
Item Inch A B C D E F G H J 0. 10 1. 75 1. 55 2. 75 2. 55 0. 35 0. 23 0. 93 mm 2. 50 Item Description K P2 20-Pin Header . 025 inch (6 mm) square pins, . 1 inch (2. 4 mm) typical spacing 0. 125 Inch (3. 2 mm) mounting holes for #4-40 (3 mm) screws P3 20-Pin Header . 025 inch (6 mm) square pins, . 1 inch (2. 4 mm) typical spacing
44. 50 L 39. 40 M 69. 90 64. 80 8. 90 5. 80 23. 6
0. 438 11. 10
AXP-CPI16 16-Channel Custom Panel Interface
5
Installation
Setting the AXlink Device Number
The 8-position device DIP switch defines the AXP-CPI16 as an AXlink device. Set the device number with the total value of all ON (down) positions. As an example, the device DIP switch shown below defines device number 129 (1+128=129).
Position 1 2 3 4 5 Value 6 7 8
OFF OFF ON ON 12345 678
1 2 4 8 16 32 64 128
AMX standard device numbers are assigned as follows: Cards are 1 through 25. [. . . ] Output channels are used to turn on the lamp or LED display devices to indicate the button status to the user. The AXP-CPI16 default mode is STATUS-OFF, and in this mode the programmer cannot poll the AXPCPI16 to determine the state of the output channel. This is because in this mode the output and input channels use the same number assignments. When set for STATUS-ON mode the output channels are assigned a different channel number than the input channels. [. . . ]