User manual AMX AXB-PT15 POSITRACK CAMERA CONTROLLER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX AXB-PT15 POSITRACK CAMERA CONTROLLER. We hope that this AMX AXB-PT15 POSITRACK CAMERA CONTROLLER user guide will be useful to you.


AMX AXB-PT15 POSITRACK CAMERA CONTROLLER : Download the complete user guide (977 Ko)

Manual abstract: user guide AMX AXB-PT15 POSITRACK CAMERA CONTROLLER

Detailed instructions for use are in the User's Guide.

[. . . ] instruction manual AXB-PT15 PosiTrack Camera Controller C a m e ra C o n t r o l l e r s AMX Limited Warranty and Disclaimer AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year. AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long as the AMX Lighting products are under warranty. AMX Corporation does guarantee the control of dimmable loads that are properly connected to our lighting products. [. . . ] Default is 2, meaning the position can be within + 2 from the specified position. 1 to 255; time in 10ms increments it takes the motor drives to ramp up to speed. All presets are cleared when any limits are set. Configuration commands configure the manner in which the PosiTrack operates. Configuration Commands ACCEL CONTROL=ON Enables acceleration control for pan/tilt (default). BUTTON PRESS Executes a series of preset 10-degree movements for both directions of pan/tilt. CHAN PRESET=ON Enables preset recalls by turning ON the preset channels 101-228. CLEAR ERRORS Clears all of the error messages obtained by using the DEVICE STATUS command in the Terminal Emulator mode. Syntax: SEND_COMMAND CAM, "'ACCEL CONTROL=ON'" Pan/Tilt movement speeds up and slows down based on PANACC, TILTACC, and PRESET ACCEL values. This affects all pan/tilt movements and results in smoother, dampened operation. Syntax: SEND_COMMAND CAM, "'ACCEL CONTROL=OFF'" Pan/Tilt movement start and stop immediately. This results in more responsive operation, although changes in speed may result in rough movements. Syntax: SEND_COMMAND CAM, "'BUTTON PRESS'" The PosiTrack moves up, home (stops), left, then stops at home. This is designed to test the functionality of the PosiTrack's field of movement. Syntax: SEND_COMMAND CAM, "'CHAN PRESET=ON'" The default mode of operation for these channels is feedback ONLY. Syntax: SEND_COMMAND CAM, "'CHAN PRESET=OFF'" Syntax: SEND_COMMAND CAM, "'CLEAR ERRORS'" Refer to the Diagnostic error values section on page 39 for detailed information. 26 AXB-PT15 PosiTrack Camera Controller Programming Configuration Commands (Cont. ) CLEAR HOME Clears the current home position and goes to the default setting and clears presets. CURRENT SPEED PRIORITY=CHANNEL Changes the operational mode of channels 31, 32, 35, and 36. CURRENT SPEED PRIORITY=LEVEL Syntax: SEND_COMMAND CAM, "'CLEAR HOME'" This command also clears all presets. Syntax: SEND_COMMAND CAM, "'CLEAR LIMIT ALL'" Syntax: SEND_COMMAND CAM, "'CLEAR LIMIT DOWN'" Syntax: SEND_COMMAND CAM, "'CLEAR LIMIT LEFT'" Syntax: SEND_COMMAND CAM, "'CLEAR LIMIT RIGHT'" Syntax: SEND_COMMAND CAM, "'CLEAR LIMIT UP'" Syntax: SEND_COMMAND CAM, "'CURRENT SPEED PRORITY=CHANNEL'" Does NOT allow pan/tilt movement from levels until channels 31, 32, 35 and 36 are turned Off. The CaMatrix is a third-party RS232 control program that runs on a PC. Syntax: SEND_COMMAND CAM, "'CURRENT SPEED PRORITY=LEVEL'" Changes the operaAllows pan/tilt movement from levels even if these channels are still On. tional mode of channels Setting this priority makes the move at current speed channels operate like the 31, 32, 35, and 36. DEFAULT ACCEL Sets the Pan and Tilt acceleration to the default value of 90 degrees/(second squared). FIND HOME Syntax: SEND_COMMAND CAM, "'DEFAULT ACCEL'" Syntax: Runs a series of pan/tilt SEND_COMMAND CAM, "'FIND HOME'" movements to After the mechanical recalibration, the unit moves to the location set via the recalibrate its "SET HOME" command (if applicable). FOCUS PRESET=POS This is applicable only if the FOCUS SIGNAL=S command is in effect, and the FOCUS switch is set to the S position (servomotor mode). Syntax: SEND_COMMAND CAM, "'FOCUS PRESET=POS'" The command for FOCUS output to servomotor mode or motor mode MUST be configured to match the switch settings. AXB-PT15 PosiTrack Camera Controller 27 Programming Configuration Commands (Cont. ) FOCUS PRESET=SPEED Sets the FOCUS voltage output to recall speed presets. [. . . ] 24). Selected device firmware file Listing of Detected Online Devices Firmware download status FIG. 24 Send to Axcess Device dialog (showing device firmware update via Serial) 6. Click the Query Online Devices button to populate the Devices section of this dialog with a listing of all Axcess devices currently communicating with the target Axcess Master. AXB-PT15 PosiTrack Camera Controller 49 Upgrading the Firmware 8. From the Device listing, click on the Device ID associated with the PosiTrack device which will be upgraded (FIG. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX AXB-PT15 POSITRACK CAMERA CONTROLLER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX AXB-PT15 POSITRACK CAMERA CONTROLLER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.