User manual ALCATEL-LUCENT OMNISTACK 8008

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ALCATEL-LUCENT OMNISTACK 8008. We hope that this ALCATEL-LUCENT OMNISTACK 8008 user guide will be useful to you.


ALCATEL-LUCENT OMNISTACK 8008 : Download the complete user guide (1259 Ko)

You may also download the following manuals related to this product:

   ALCATEL-LUCENT OMNISTACK 8008 GETTING STARTED (1038 ko)

Manual abstract: user guide ALCATEL-LUCENT OMNISTACK 8008

Detailed instructions for use are in the User's Guide.

[. . . ] B January 2002 OmniStack® 8008 Users Guide An Alcatel service agreement brings your company the assurance of 7x24 no-excuses technical support. You'll also receive regular software updates to maintain and maximize your Alcatel product's features and functionality and on-site hardware replacement through our global network of highly qualified service delivery partners. Additionally, with 24-hour-a-day access to Alcatel's Service and Support web page, you'll be able to view and update any case (open or closed) that you have reported to Alcatel's technical support, open a new case or access helpful release notes, technical bulletins, and manuals. For more information on Alcatel's Service Programs, see our web page at www. ind. alcatel. com, call us at 1-800-995-2696, or email us at support@ind. alcatel. com. This Manual documents OmniStack® 8008 hardware and software. [. . . ] Configure it with a valid IP address, subnet mask, and default gateway using an out-of-band serial connection or BOOTP protocol. Access to the Web agent is controlled by the same user name and password as the onboard configuration program. 3-1 Web Interface Navigating the Web Browser Interface To access the Web-browser interface you must first enter a user name and password. The administrator has Read/Write access to all configuration parameters and statistics. The default user name for the administrator is "admin, " with the password "switch. " Home Page When your Web browser connects with the switch's Web agent, the home page is displayed as shown below. The home page displays the Main Menu on the left side of the screen and System Information on the right side. The Main Menu links are used to navigate to other menus and display configuration parameters and statistical data. If this is your first time to access the management agent, you should define a new Administrator password, record it and put it in a safe place. From the Main Menu, select Security and enter a new password for the Administrator. Note that passwords can consist of up to 11 alphanumeric characters and are not case sensitive. Note: Based on the default configuration, a user is allowed three attempts to enter the correct password; on the third failed attempt the current connection is terminated. See "Console Login Configuration" on page 2-17. 3-2 Navigating the Web Browser Interface Configuration Options Configurable parameters have a dialog box or a drop-down list. Once a configuration change has been made on a page, be sure to click on the "Apply" button at the bottom of the page to confirm the new setting. The following table summarizes the Web page configuration buttons. Web Page Configuration Buttons Button Apply Revert Refresh Action Sets specified values in the SNMP agent. Cancels specified values prior to pressing the "Apply" button. To ensure proper screen refresh, be sure that Internet Explorer 5. 0 is configured as follows: Under the menu "Tools / Internet Options / General / Temporary Internet Files / Settings, " the setting for item "Check for newer versions of stored pages" should be "Every visit to the page. " 2. When using Internet Explorer 5. 0, you may have to manually refresh the screen after making configuration changes by pressing the browser's refresh button. 3-3 Web Interface Panel Display The Web agent displays an image of the switch's ports, showing port links and activity. Clicking on the image of a port displays statistics and configuration information for the port. Clicking on the image of the serial port (labeled "Mgmt") displays the Console Configuration screen. Clicking on any other part of the front panel displays Switch Information as described on page 3-7. Port State Display Click on any port to display a summary or port status as shown below, as well as Etherlike statistics (page 3-39) and RMON statistics (page 3-40). Parameter Type Admin Status Link Status Speed Status Duplex Status Flow Control Status VLAN Description Shows port type as 1000BASE-SX Shows if the port is enabled, or has been disabled due to abnormal behavior or for security reasons. Flow control can eliminate frame loss by "blocking" traffic from end stations connected directly to the switch. Use the PVID (page 3-30) to assign ports to the same untagged VLAN. 3-4 Panel Display Configuring the Serial Port If you are having difficulties making an out-of-band console connection to the serial port on the switch, you can display or modify the current settings for the serial port through the Web agent. Click on the serial port icon in the switch image to display or configure these settings, as shown below. Parameter Baud Rate Time-Out Default 9600 10 minutes Description The rate at which data is sent between devices. If no input is received from the attached device after this interval, the current session is automatically closed. Range : 0 - 100 minutes; where 0 indicates disabled Sets the data bits of the RS-232 port. [. . . ] Change your baud rate to 115200 bps, and press Enter to enable download. From the terminal emulation program, select the file you want to download, set the protocol to XModem, and then initialize downloading. Notes: 1. The download file must be the correct binary file for the switch; otherwise the agent will not accept it. 4. After the file has been downloaded, the console screen will display information similar to that shown below. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ALCATEL-LUCENT OMNISTACK 8008




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ALCATEL-LUCENT OMNISTACK 8008 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.