User manual ALCATEL-LUCENT OMNISTACK 6124

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ALCATEL-LUCENT OMNISTACK 6124. We hope that this ALCATEL-LUCENT OMNISTACK 6124 user guide will be useful to you.


ALCATEL-LUCENT OMNISTACK 6124 : Download the complete user guide (847 Ko)

You may also download the following manuals related to this product:

   ALCATEL-LUCENT OMNISTACK 6124 GETTING STARTED GUIDE (1024 ko)

Manual abstract: user guide ALCATEL-LUCENT OMNISTACK 6124

Detailed instructions for use are in the User's Guide.

[. . . ] A February 2002 OmniStack® 6124 Users Guide An Alcatel service agreement brings your company the assurance of 7x24 no-excuses technical support. You'll also receive regular software updates to maintain and maximize your Alcatel product's features and functionality and on-site hardware replacement through our global network of highly qualified service delivery partners. Additionally, with 24-hour-a-day access to Alcatel's Service and Support web page, you'll be able to view and update any case (open or closed) that you have reported to Alcatel's technical support, open a new case or access helpful release notes, technical bulletins, and manuals. For more information on Alcatel's Service Programs, see our web page at www. ind. alcatel. com, call us at 1-800-995-2696, or email us at support@ind. alcatel. com. This Manual documents OmniStack 6124 hardware and software. [. . . ] The status for an entry can be set to: Permanent This entry is currently in use and will remain so after the next reset of the switch. DeleteOnReset This entry is currently in use and will remain so until the next reset. DeleteOnTimeOut This entry is currently in use and will remain so until it is aged out. (Refer to "Aging Time" on page 2-53. ) Other This entry is currently in use but the conditions under which it will remain so differ from the preceding values. Note that only VID+MAC is implemented in the current firmware release. Displays the static address table sorted on VID as the primary key and MAC address as secondary key. Adds the specified entry to the static address table, such as shown in the following example: VID Unit Status :1 MAC : 00-00-00-e8-34-22 :1 Port: 1 : Permanent Sorted by [Show] [More] [Set] 2-55 Using the System Configuration Program Resetting the System Use the Restart command under the Main Menu to reset the management agent. The reset screen includes options as shown in the following figure and table. Alcatel OmniStack 6124 < Reset System Menu > Restart Option : POST Reload Factory Defaults Keep IP Setting Keep User Authentication [Restart] : : : : YES NO NO NO <Apply> <Ok> <Cancel> Use <TAB> or arrow keys to move, <Space> to scroll options. Menu POST Reload Factory Defaults Keep IP Setting Keep User Authentication [Restart] Description Runs the Power-On Self-Test Reloads the factory defaults Retains the settings defined in the IP Configuration menu. Retains the user names and passwords defined in the Console Login Configuration menu. Restarts the switch. Logging Off the System Use the Exit command under the Main Menu to exit the configuration program and terminate communications with the switch for the current session. 2-56 Chapter 3: Web-Based Management Web-Based Configuration and Monitoring As well as the menu-driven system configuration program, the agent module provides an embedded HTTP Web agent. This agent can be accessed by any computer on the network using a standard Web browser (Internet Explorer 4. 0 or above, or Netscape Navigator 4. 0 or above). Using the Web browser management interface you can configure a switch and view statistics to monitor network activity. The Web interface also provides access to a range of SNMP management functions with access to the switch's MIB and RMON database. Prior to accessing the switch from a Web browser, be sure you have first performed the following tasks: 1. Configure it with a valid IP address, subnet mask, and default gateway using an out-of-band serial connection or BOOTP protocol. Set the Administrator user name and password using an out-of-band serial connection. Access to the Web agent is controlled by the same Administrator user name and password as the on-board configuration program. 3-1 Web-Based Management Navigating the Web Browser Interface To access the Web-browser interface you must first enter a user name and password. The default user name is "admin, " with a password of "switch. " The administrator has Read/Write access to all configuration parameters and statistics. Home Page When your Web browser connects with the switch's Web agent, the home page is displayed as shown below. The home page displays the Main Menu on the left-hand side of the screen and System Information on the right-hand side. The Main Menu links are used to navigate to other menus and display configuration parameters and statistical data. If this is your first time to access the management agent, you should define a new Administrator password, record it and put it in a safe place. From the Main Menu, select Security and enter a new password for the Administrator. Note that passwords can consist of up to 11 alphanumeric characters and are not case sensitive. Note: Based on the default configuration, a user is allowed three attempts to enter the correct password; on the third failed attempt the current connection is terminated. [. . . ] PASS MAC Address . . . . . . . . . . . . . . 00-10-b5-fd-84-bb ----------Power-On-Self-Test Completed ---------(D)ownload System Image or (S)tart Application: [S] Select the Firmware Type to Download (1)Runtime (2)POST (3)Mainboard [1]: For example, if you select 1 (for downloading agent firmware), the system will display the following message: (D)ownload System Image or (S)tart Application: [S] Select the Firmware Type to Download (1)Runtime (2)POST (3)Mainboard [1]: 1 Your Selection: Runtime Code Download code to FlashROM address 0x02880000 3. Change your baud rate to 115200 bps, and press Enter to enable download mode. From the terminal emulation program, select the file you want to download, set the protocol to XModem, and then initialize downloading. Notes: 1. If you use Windows HyperTerminal, disconnect enable the new baud rate. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ALCATEL-LUCENT OMNISTACK 6124




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ALCATEL-LUCENT OMNISTACK 6124 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.