User manual ALCATEL-LUCENT OMNIACCESS 6000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ALCATEL-LUCENT OMNIACCESS 6000. We hope that this ALCATEL-LUCENT OMNIACCESS 6000 user guide will be useful to you.


ALCATEL-LUCENT OMNIACCESS 6000 : Download the complete user guide (1241 Ko)

You may also download the following manuals related to this product:

   ALCATEL-LUCENT OMNIACCESS 6000 FAN TRAY INSTALLATION GUIDE (86 ko)
   ALCATEL-LUCENT OMNIACCESS 6000 LC-2G24FP INSTALLATION GUIDE (132 ko)
   ALCATEL-LUCENT OMNIACCESS 6000 OAW-LC-2G24F INSTALLATION GUIDE (129 ko)
   ALCATEL-LUCENT OMNIACCESS 6000 SUPERVISOR CARD INSTALLATION GUIDE (123 ko)
   ALCATEL-LUCENT OMNIACCESS 6000 200W POWER SUPPLY INSTALLATION GUIDE (111 ko)
   ALCATEL-LUCENT OMNIACCESS 6000 400W POWER SUPPLY INSTALLATION GUIDE (186 ko)

Manual abstract: user guide ALCATEL-LUCENT OMNIACCESS 6000

Detailed instructions for use are in the User's Guide.

[. . . ] OmniAccess 6000 TM Wireless LAN Switch Installation Guide i OmniAccess 6000: Installation Guide Copyright Copyright © 2005 Alcatel Internetworking, Inc. Originated in the USA. Trademarks Alcatel AP60/61, Alcatel 70, Alcatel 6000, and Alcatel AOS-W, are trademarks of Alcatel in the United States and certain other countries. Any other trademarks appearing in this manual are owned by their respective companies. ii Part 031639-00 May 2005 Electromagnetic Interference FCC - Class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. [. . . ] Protection DC Okay Middle AC Okay Bottom Green Off TABLE 5-2 400 W Power Supply LEDs LED Name Position State Off Red Green Red Description Power supply temperature is okay. Protection DC Okay Middle AC Okay Bottom Green Red 4 Air Intake Vent This air intake vent helps the internal fan cool the power supply during operation. To prevent blockage, keep all material at least 10 cm (4 inches) from the vent. 5 Power Cord Retaining Clip (optional 400 W OWA-6000-PS400 only) This clip fits over the power cord once the plug has been inserted into the power input socket. It helps prevent the power cord from being pulled out accidentally. 26 Part 031639-00 May 2005 Chapter 5 6 Power Input Socket The power input socket accepts a power cord with a standard IEC320 connector. For proper safety and performance, the power cord must be rated to 10 A and conform to grounded electrical standards in the country where the product is operated. 7 Power Switch The power switch has two states: Off ( ) and On (|). Power Management Power Requirements Worksheet Use this worksheet to determine the power required by your Alcatel Wireless LAN Switch. Use a separate copy for each system deployed in your network. Name of Alcatel Wireless LAN Switch Location The Power Supply 27 OmniAccess 6000: Installation Guide TABLE 5-3 Alcatel 6000-series Power Requirements Component Name Model Number Power Rating 12 W x x Number Power = of Units Subtotal 1 = 12 W Alcatel 6000-series Fan Tray OWA-6000FT Alcatel 6000 Supervisor Card with Crypto Accelerator Alcatel 6000 Line Card (24 FE and 2 GE ports) Alcatel 6000 Line Card (24 FE+SPOE and 2 GE ports) OWA-SC-2 OWA-LC-2G 24F OWA-LC-2G 24FP 50 W x = 40 W x = 40 W x = Alcatel 2 GE Line Card with support for two GBIC OWA-LC-2G uplinks. ) Each Alcatel AP Drawing POE from a Line Card Each Cisco 1200 AP Drawing POE from a Line Card Each other Access Point Drawing POE from a Line Card AP60, AP61, AP70 40 W x = 10 W x = 12 W x = W x = Total power required by the switch in Watts: NOTE--Recalculate these numbers whenever components are added to the system. 28 Part 031639-00 May 2005 Chapter 5 Required Power Supplies Once you've calculated the total power required by your Alcatel Wireless LAN Switch, you can easily determine the type and number of power supplies required: TABLE 5-4 Required Power Supplies Total Power Required 200 W or less 400 W or less 800 W or less 1200 W or less Over 1200 W Power Supplies Required One 200 W supply, or One 400 W supply Two 200 W supplies, or One 400 W supply Two 400 W supplies Three 400 W supplies Not supported Required for Redundancy Two 200 W supplies, or Two 400 W supplies Two 400 W supplies Three 400 W supplies Not supported Not supported Verify that the switch has enough power supplies to handle the expected load. Maximum Power Load The maximum power load depends on the type and number of power supplies installed. Use these worksheets to calculate the total power demand placed on your site's electrical circuits: TABLE 5-5 Maximum Load using 200 W Power Supplies Component Description Total power required (from worksheet on page 27) 200 W Power Supply (OWA-6000-PS200) overhead Power W x Factor = Power Subtotal x 1. 3 safety = x 8W units = Maximum power load in Watts: The Power Supply 29 OmniAccess 6000: Installation Guide TABLE 5-6 Maximum Load using 400 W Power Supplies Component Description Total power required (from worksheet on page 27) 400 W Power Supply (OWA-6000-PS400) overhead Power W x x x Factor 1. 25 safety = = Power Subtotal 26 W units = Maximum power load in Watts: Verify that the maximum power load does not exceed the capacity of your electrical circuits. Inserting a Power Supply CAUTION--This procedure should be performed by a trained technician. 1 Verify you understand the procedure and all precautions. Before beginning, read the entire procedure. Verify you understand all the precautions in these steps as well as those on page 6. 2 Select a power supply slot for the power supply. The 200 W power supply (OWA-6000-PS200) can be installed in power supply slots 1 and 3 only. The 400 W power supply (OWA-6000-PS400) can be installed in any power supply slot: FIGURE 5-2 Alcatel 6000-series Power Supply Slots 30 Part 031639-00 May 2005 Chapter 5 NOTE--When using more than one power supply, verify that they are all of the same type. If replacing a previously installed power supply, first see "Removing a Power Supply" on page 33. If you are installing a power supply in an empty slot, you may have to remove the blank cover plate first. Turn the captive fastening screws on the faceplate counter-clockwise until they are loose (they cannot be completely removed). 3 Verify the power switch on the power supply to be installed is Off ( ). CAUTION--Never insert or remove a power supply while its power switch is in the On (|) position. Verify the power switch is Off ( ) first. 4 Insert the power supply into the chassis. Grasp the power supply by the handle, keeping the LEDs on the left and power switch on the right. Align the back of the module with the guide-rails in the chassis power supply slot and gently slide the module toward the backplane. There may be moderate resistance when the power supply meets the connectors at the back of the chassis. Press firmly to engage the connectors, but do not use excessive force. 5 Secure the power supply. Use the screwdriver to push in the module's captive fastening screws and turn them clockwise until moderate resistance is felt. Do not over-tighten. 6 Attach the power cord to the power supply. Plug an appropriate power cord into the power input socket. CAUTION--For proper safety and performance, the power cord must be rated to 10 A and conform to grounded electrical standards in the country where the product is operated. NOTE--On the 400 W power supply (OWA-6000-PS400), swing the cord retaining clip to the left before attaching the power cord. The Power Supply 31 OmniAccess 6000: Installation Guide 7 Secure the power cord (optional 400 W OWA-6000-PS400 only). When the power cord is attached, swing the power cord retaining clip to the right as shown in Figure 5-3. This will hold the plug in place and help prevent it from being removed accidentally. Right: Capture Cord Wrong: Around Plug Base FIGURE 5-3 Using the Power Cord Retaining Clip 8 Attach the power cord to a proper electrical outlet. Verify that your site's electrical systems can handle the switch's power load. Each standard power supply (OWA-6000-PS200) is rated at 200 W total and is auto-ranging to accept 90-132/ 170-264 VAC, at 50 to 60 Hz. [. . . ] 1 Verify you understand the procedure and all precautions. Before beginning, read the entire procedure. Verify you understand all the precautions in these steps as well as those on page 6. 2 Prepare the slot. The first line card should be installed in Slot 2 of the Alcatel Wireless LAN Switch chassis. A second optional line card can be installed in Slot 3, and a third in Slot 1. CAUTION--If installing a line card in Slot 1, verify that the fastening screws for the module in the slot above it are fully secured. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ALCATEL-LUCENT OMNIACCESS 6000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ALCATEL-LUCENT OMNIACCESS 6000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.