User manual ALARIS GS SYRINGE PUMP

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ALARIS GS SYRINGE PUMP. We hope that this ALARIS GS SYRINGE PUMP user guide will be useful to you.


ALARIS GS SYRINGE PUMP : Download the complete user guide (1067 Ko)

Manual abstract: user guide ALARIS GS SYRINGE PUMP

Detailed instructions for use are in the User's Guide.

[. . . ] Alaris GS Syringe Pump ® Directions For Use - English s Contents Page Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quick Start Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features of the Alaris® GS Syringe Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Sets the Near End Of Infusion warning time, as time left to End Of Infusion. When enabled the pump will switch to running at the KVO rate when EOI is reached. Sets the Keep Vein Open (KVO) rate at which the pump will operate if KVO at EOI is enabled. When enabled the motor will reverse to relieve line pressure when an occlusion occurs. When enabled the rate can be locked to prevent unwanted changes of the set infusion rate. When enabled the AC Power Failure Alarm will sound if the AC power is disconnected. Volume infused will be increased if plunger is manually moved in and syringe remains confirmed. Enables / disables the Battery Icon feature availability via the d button. Select CLOCK SET from the Configured Options menu using the f keys and press the OK softkey. Use the f keys to adjust the date displayed, pressing the NEXT softkey to access the next field. When the correct time and date are displayed press the OK softkey to return to the Configured Options menu. Hospital Name This option allows the user to programme in the name of the hospital, ward or department. Select HOSPITAL NAME from the Configured Options menu using the f keys and press the OK softkey. Use the keys to adjust the character displayed, pressing NEXT to access the next position. When the correct name is displayed press OK to return to the Configured Options menu. Enable Syringes This option is used to pre-configure the type and size of syringe permitted for use on the pump. Select all possible syringes which may be used and disable any that should not be used. Select ENABLE SYRINGES from the Configured Options menu using the f keys and press the OK softkey. Use the f keys to scroll through the list of syringes, pressing MODIFY to enable/disable a syringe brand and individual models within the brand. When all modifications are complete press OK to return to the Configured Options menu. Language This option is used to set the language of messages shown on the pump display. Select LANGUAGE from the Configured Options menu using the f keys and press the OK softkey. When the desired language has been selected press SELECT softkey to return to the Configured Options menu. Contrast This option is used to set the contrast on the pump display. Select CONTRAST from the Configured Options menu using the f keys and press the OK softkey. The contrast of the display will change when scrolling through the numbers. [. . . ] Tel: (46) 8 544 43 200 Fax: (46) 8 544 43 225 Document History Revision 1 2 3 CO Number 5960 6881 7109 Date October 05 May 06 August 06 1000DF00001 Iss. 3 29/32 Warranty Cardinal Health, Alaris® Products ("Cardinal Health") warrants that: (A) Each new infusion instrument (pump, controller or peripheral instrument) is free from defects in material and workmanship under normal use and service for a period of two (2) years from the date of delivery by Cardinal Health to the original purchaser. (B) Each new accessory is free from defects in material and workmanship under normal use and service for a period of ninety (90) days from the date of delivery by Cardinal Health to the original purchaser. (C) Each Mains Cable, Battery, Flow Sensor (ECD) and non-disposable probe is free from defects in material and workmanship under normal use and service for a period of ninety (90) days from the date of delivery by Cardinal Health to the original purchaser. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ALARIS GS SYRINGE PUMP




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ALARIS GS SYRINGE PUMP will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.