User manual AKG MCS 4000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AKG MCS 4000. We hope that this AKG MCS 4000 user guide will be useful to you.


AKG MCS 4000 : Download the complete user guide (2215 Ko)

You may also download the following manuals related to this product:

   AKG MCS 4000 (2220 ko)

Manual abstract: user guide AKG MCS 4000

Detailed instructions for use are in the User's Guide.

[. . . ] wireless microphone system WMS4000 MCS mission control software (Windows) 4000 l softwa tro r e M CS 00 40 m Please read the manual before using the equipment! User Manual on issi con MCS 4000 mission control software Environment The packaging of the equipment is recyclabe. Observe local legislation relating to waste disposal and recycling and dispose of packaging materials in the appropriate waste collection/recycling containers. Table of Contents Seite 1 Description . 12 2 MCS 4000 mission control software 1 Description MCS 4000 allows you to monitor and configure a WMS 4000 multichannel system and one or several HUB 4000s from a standard computer (PC or Mac) using a network cable. The adjustable parameters and warning messages are identical to those of the SR 4000 receiver. [. . . ] If you'd rather not save the setting, move the cursor to the red St. Andrew's cross and click on "Cancel SR configuration changes". To save your setting, move the cursor to the green tick and click on "Confirm SR configuration changes". If you'd rather not save the setting, move the cursor to the red St. Andrew's cross and click on "Cancel SR configuration changes". Band Preset Frequency Name 1. 4. Squelch This tab indicates the current squelch threshold setting (see also the SR 4000 manual). Click on the black arrow to open a list of threshold settings between -80 dB and - 100 dB. Alternatively, you can select "TCSQ" to activate the tone code squelch for automatic wanted-signal detection. To save your setting, move the cursor to the green tick and click on "Confirm SR configuration changes". If you'd rather not save the setting, move the cursor to the red St. Andrew's cross and click on "Cancel SR configuration changes". The current threshold setting is also indicated by a small mark on the RF Info bar in the MCS 4000 Control Center main screen. Note: 7 MCS 4000 mission control software 3. 5 Automatic Receiving Frequency Programming 3. 5. 1 Setting Auto Setup Parameters 1. From the menu bar, select "Tools" - "Config. . . " - "Configure Auto Setup". Note: You may even select several Presets, e. g. , if the same Preset is not available for all bands. 8 MCS 4000 mission control software Auto Setup Assistant will start analyzing the RF environment (Environment Scan). Note: You can monitor this process on the screen by selecting "Watch environment scan". This will bring up the following window: Environment Scan detects potentially interfering transmitters or strong intermodulating transmitters above/below the threshold settings you selected in "Config. . . " - "Configure Auto Setup". Since the system will scan the entire 30 MHz-wide frequency band, it is imperative that you switch on all other transmitters near your WMS 400 system to get a meaningful analysis. Note: If your system uses several bands, click on the upper left-hand tab in the "Environment Scan" window to select the desired band. Once the RF environment has been scanned, the receivers connected to the system will be automatically set to new interference and intermodulation-free frequencies and unused receivers will be switched off. The following window appears as the programming starts: 9 MCS 4000 mission control software The changes you may have made will also be documented in the Report. Set the transmitter assigned to each receiver to the appropriate frequency. [. . . ] The "+" and "-" zoom buttons toggle the resolution of the time axis in the left-hand section of the Rehearsal Check window between 10 minutes and 1 minute. The reception levels at the antennas are shown as traces and saved to the hard disk. The data recorded during the last 5 hours will remain stored unless you clear the recorded data with the "Clear History" command. (Note that "Clear History" does not stop the recording. ) The right-hand section of the window shows the current status at a resolution of 10 seconds. · Monitoring Several Channels Simultaneously · Resolution · Recording RF Data 11 MCS 4000 mission control software · Changing the Window Size 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AKG MCS 4000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AKG MCS 4000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.