User manual AEG-ELECTROLUX RM2280

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG-ELECTROLUX RM2280. We hope that this AEG-ELECTROLUX RM2280 user guide will be useful to you.


AEG-ELECTROLUX RM2280 : Download the complete user guide (396 Ko)

You may also download the following manuals related to this product:

   AEG-ELECTROLUX RM2280 (405 ko)
   AEG-ELECTROLUX RM2280 (397 ko)
   AEG-ELECTROLUX RM2280 (370 ko)
   AEG-ELECTROLUX RM2280 (718 ko)
   AEG-ELECTROLUX RM2280 (725 ko)
   AEG-ELECTROLUX RM2280 (636 ko)
   AEG-ELECTROLUX RM2280 (676 ko)
   AEG-ELECTROLUX RM2280 (342 ko)

Manual abstract: user guide AEG-ELECTROLUX RM2280

Detailed instructions for use are in the User's Guide.

[. . . ] Transit damage must be reported to whoever is responsible for delivery not later than seven days after the refrigerator was delivered. DATA PLATE Check the data plate, inside the refrigerator, to ensure that you have received the right model. the following details: Model designation Product number Serial number Voltage Gas pressure RM 4601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . kPa Since these details will be needed if you have to contact service personnel, it is a good idea to make a note of them here. Push the button (D) in until it reaches the bottom and hold, push the button (C) for the piezo igniter several times to light the burner. [. . . ] Connect two wires at the refrigerator and route directly to the 12 volt DC supply. To avoid a voltage drop, the cross section area of the connecting cables between battery/alternator and the refrigerator must be 10 mm2. To ensure satisfactory operation, the positive lead must be fitted with a fuse rated at 25 A. To prevent the refrigerator from draining the battery, make sure that the current supplied to the caravan is cut off when the vehicle engine is not running, for example by fitting an ignition control relay. WARNING! DO NOT use a flame to check for gas leaks. On completion of installation, the system must be pressure tested by a qualified technician. 12 V DC Reigniter Lamp Heater ELECTRICAL CONNECTION The electrical installation must be carried out in a proper and durable manner; taking into accounts all relevant regulations and codes of practice. For mains voltage operation, it is important that the circuit to and in the caravan is effectively earthed. The refrigerator is equipped with a three-prong (grounding) plug for your protection against shock hazards and should be plugged directly into a properly grounded threeprong receptacle. The free length of the cord is 1. 8 m and therefore recommended that the receptacle be located to the left side of the refrigerator (viewed from the rear) and approximately 100-150 mm from the floor. 7 TECHNICAL DATA RM 4601 Overall dimensions, refrigerator Height (incl. 668 Recess dimensions Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 440 Cooling medium: Ammonia mm mm mm mm mm mm litres litres litres kg watt watt kWh MJ/h g 230-240 V Supplies. Check that the voltage stated on the data plate is the same as the main voltage in use (230-240 V). Note: there is no thermostat function on 12 V operation, the refrigerator works continuously. To shut off the refrigerator, turn the knob (A) to "OFF" position. REGULATING THE TEMPERATURE The position number refers to fig. 1. It will take a few hours for the refrigerator to reach normal operating temperature. So we suggest you start it well in advance of a trip and if possible store it with precooled foodstuffs. On 230-240 V operation and LP gas operation the refrigerator is controlled by a thermostat and the thermostat knob (D) should be set at 3-5. If a lower (colder) temperature is desired set the thermostat to a higher figure. On 12 V operation the refrigerator works continuously. STARTING THE REFRIGERATOR All references are to fig. 1. WARNING! DO NOT OPERATE THE REFRIGERATOR ON LP GAS WHILST TRAVELLING TRAVEL CATCH The travel catch is integrated in the handle. Make sure that the travel catch is engaged when the caravan is on the move. LP Gas operation After initial installation, servicing, or changing gas cylinders etc. , the gas line is likely to be filled with air. You may have to repeat the lighting procedure several times to purge the air out of the gas lines. Open the shut off valve of the gas bottle (check that there is enough gas). [. . . ] The Dometic ventilation grilles permit inspection and small repairs to be carried out without the necessity of removing the refrigerator from the recess. 16 The supply pipe should preferable be of copper. If any other material is used, it must be of a type approved for use with continuously operating bottled-gas appliances and have threaded connections throughout. should be of a type specifically designed for the type and diameter of the connection pipe used, and screwed joints should be sealed with a joining compound approved for use with bottled-gas. The gas supply pipe should be connected to the gas inlet connection at the rear of the refrigerator by means of a suitable threaded coupling. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX RM2280




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX RM2280 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.