User manual AEG-ELECTROLUX EXS12HC1WI

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG-ELECTROLUX EXS12HC1WI. We hope that this AEG-ELECTROLUX EXS12HC1WI user guide will be useful to you.


AEG-ELECTROLUX EXS12HC1WI : Download the complete user guide (1160 Ko)

Manual abstract: user guide AEG-ELECTROLUX EXS12HC1WI

Detailed instructions for use are in the User's Guide.

[. . . ] Website: www. mideaaircon. com Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORIZED SERVICE PERSONNEL. MODELS: EL-KF20GW/N2Y-A(B) EL-KF36GW/N2Y-A(B) EL-KF61GW/N2Y-A(B) EL-KFR20GW/N1Y-A(B) EL-KF20GW/Y-A(B) EL-KF32GW/Y-A(B) EL-KF50GW/Y-A(B) EL-KF70GW/Y-A(B) EL-KF90GW/SY-A(B) AU-KF70GW/Y-A(B) EL1-KF20GW/Y-A(B) EL1-KF32GW/Y-A(B) EL1-KF26GW/N2Y-A(B) EL-KT3F53GW/Y-T2 EL-KT3F70GW/Y-T2 SEL-KF20GW/Y-A(B) SEL-KF32GW/Y-A(B) SEL-KF61GW/Y-A(B) SEL1-KF26GW/Y-A(B) EL-KFR20GW/N2Y-A(B) EL-KFR36GW/N2Y-A(B) EL-KFR61GW/N2Y-A(B) EL-KFR26GW/N1Y-A(B) EL-KFR20GW/Y-A(B) EL-KFR32GW/Y-A(B) EL-KFR50GW/Y-A(B) EL-KFR70GW/Y-A(B) EL-KFR90GW/SY-A(B) AU-KFR70GW/Y-A(B) EL1-KFR20GW/Y-A(B) EL1-KFR32GW/Y-A(B) EL1-KFR26GW/N2Y-A(B) EL-KT3F53GW/Y-T1 EL-KT3F70GW/Y-T1 SEL-KFR20GW/Y-A(B) SEL-KFR32GW/Y-A(B) SEL-KFR61GW/Y-A(B) SEL1-KFR26GW/Y-A(B) EL-KF26GW/N2Y-A(B) EL-KF50GW/N2Y-A(B) EL-KF70GW/N2Y-A(B) EL-KFR36GW/N1Y-A(B) EL-KF26GW/Y-A(B) EL-KF36GW/Y-A(B) EL-KF61GW/Y-A(B) EL-KF90GW/Y-A(B) AU-KF61GW/Y-A(B) AU-KF85GW/Y-A(B) EL1-KF26GW/Y-A(B) EL1-KF20GW/N2Y-A(B) EL1-KF35GW/N2Y-A(B) EL-KT3FR53GW/Y-T1 EL-KT3FR70GW/Y-T1 SEL-KF26GW/Y-A(B) SEL-KF53GW/Y-A(B) SEL-KF70GW/Y-A(B) SEL1-KF36GW/Y-A(B) SEL-KFR26GW/Y-A(B) SEL-KFR53GW/Y-A(B) SEL-KFR70GW/Y-A(B) SEL1-KFR36GW/Y-A(B) EL-KFR26GW/Y-A(B) EL-KFR36GW/Y-A(B) EL-KFR61GW/Y-A(B) EL-KFR90GW/Y-A(B) AU-KFR61GW/Y-A(B) AU-KFR85GW/Y-A(B) EL1-KFR26GW/Y-A(B) EL1-KFR20GW/N2Y-A(B) EL1-KFR35GW/N2Y-A(B) EL-KFR26GW/N2Y-A(B) EL-KFR50GW/N2Y-A(B) EL-KFR70GW/N2Y-A(B) 0 GD Midea Refrigerant Equipment Co. PREFACE 1. 1 SAFETY PRECAUTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1. 2 INSULATION RESISTANCE TEST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1. 3 FEATURES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1. 4 CONTROL LOCATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1. 5 OUTSIDE DIMENSIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2. INSTALLATION 2. 1 TOOLS NEEDED FOR INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2. 2 ITEMS REQUIRED FOR INSTALLING THE UNIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2. 3 INSTALLATION OF INDOOR UNIT AND OUTDOOR UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2. 4 FLARING WORK AND CONNECTION OF PIPING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2. 5 CONNECTING THE CABLE BETWEEN INDOOR UNIT AND OUTDOOR UNIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2. 6 CHECKING THE DRAINAGE AND FORMING THE PIPING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2. 7 AIR PURGING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2. 8 TEST RUNNING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3. [. . . ] An isolation device to adequately disconnect all supply lines must be fitted. 6) Confirm that the cable thickness is as specified in the power source specification. (Refer to page 11. ) 7) Always install a Residual Current Device (RCD) in wet or moist area. Vibration of a contactor, which will damage the contact point, fuse blowing, disturbance of the normal function of the overload. 9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an air gap contact separation of at least 3mm in each active (phase) conductor. If a power plug is not to be used, provide a Circuit Breaker/Fuse between power source and the unit as shown in adjacent diagram. CAUTIONS: After confirming the above conditions, prepare the wiring as follows: 1) Never fail to have an individual power circuit 13 GD Midea Refrigerant Equipment Co. Ltd Service manual for Electrolux split Series 2. 6 CHECKING THE DRAINAGE AND FORMING THE PIPE 2. 6. 1 Checking the drainage 2. 6. 1. 1 To remove the front panel from the indoor unit. Pull the lower left and right sides of the grille toward you and lift it up. 2. 6. 2. 2 In cases where the outdoor unit is installed below the indoor unit perform the following. Secure the tapped piping along the exterior wall using saddle or equivalent. 2. 6. 1. 2 To check the drainage. Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit. 2. 6. 2. 3 In cases where the outdoor unit is installed above the indoor unit perform the following. 2. 6. 1. 3 Drain piping The drain hose should point downward for easy drain flow. Do not make drain piping similar to diagrams shown below. 2. 6. 2 Form the piping 2. 6. 2. 1 Form the piping by wrapping the connecting portion of the indoor unit with insulation material and secure it with narrow vinyl tape and wide vinyl tape. If you want to connect an additional drain hose, the end of the drain outlet should be routed above the ground. Secure the drain hose appropriately. 14 GD Midea Refrigerant Equipment Co. Ltd Service manual for Electrolux split Series 2. 7 AIR PURGING 2. 7. 1 Air purging Air and moisture remaining in the refrigerant system have undesirable effects as indicated below. Moisture in the refrigerant circuit may freeze and block capillary tubing. Therefore, the indoor unit and tubing between the indoor and outdoor unit must be leak tested and evacuated to remove any non-condensable substance and moisture from the system. 2. 7. 2 Air purging with vacuum pump 2. 7. 2. 1 Preparation Check that each tube (both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit. Note that both the liquid and the gas side service valves on the outdoor unit are kept closed at this stage. 2. 7. 2. 2 Leak test Connect the manifold set (with pressure gauges) and dry nitrogen gas cylinder to this service port with charge hoses. The "Hi" knob of the manifold valve must always be kept closed. 145psi) with dry nitrogen gas and close the cylinder valve when the gauge reading reaches 1MPa (Approx. [. . . ] Correct the installation if not correct. Correct it. It's normal if the humidity in the room is over 85%. Correct if the commucication wire is not shielded wire or twisted with other wires. Replace if the LED is not on. 25 GD Midea Refrigerant Equipment Co. Ltd Service manual for Electrolux split Series 4 WIRING DIAGRAM 4. 1 WIRING DIAGRAM FOR INDOOR UNITS 4. 1. 1 For models: EL-KF20GW/N2Y-A(B) EL-KF20GW/Y-A(B) EL1-KF20GW/Y-A(B) EL1-KF20GW/N2Y-A(B) EL-KF26GW/N2Y-A(B) EL-KF26GW/Y-A(B) EL1-KF26GW/Y-A(B) EL1-KF26GW/N2Y-A(B) EL-KF32GW/Y-A(B) EL1-KF32GW/Y-A(B) POWER SUPPLY BROWN INDOOR MOTOR Y/G BLUE BLACK 135 135 CN6 CN11 321 321 CN4 1 23 45 12345 CN12 21 21 CN2 21 21 CN3 RED C N5 P IP E TE MP ER AT UR E SE NS OR STEP MOT OR RO OM T EM P ER AT UR E S EN S OR 8 7 6 5 4 32 1 COMPRESSOR RELAY C N1 5 CN1 1 1 3 3 Y/G 1 2(N) 3 4 INDOOR UNIT TO OUTDOOR UNI T TRANSFORMER J1 X 4. 1. 2 For models: EL-KFR20GW/N2Y-A(B) EL-KFR20GW/Y-A(B) EL-KFR20GW/N1Y-A(B) EL1-KFR20GW/Y-A(B) EL1-KFR26GW/N2Y-A(B) EL-KFR26GW/N2Y-A(B) EL-KFR26GW/Y-A(B) EL-KFR26GW/N1Y-A(B) EL1-KFR26GW/Y-A(B) EL1-KFR35GW/N2Y-A(B) EL-KFR36GW/N2Y-A(B) EL-KFR32GW/Y-A(B) EL-KFR36GW/N1Y-A(B) EL1-KFR32GW/Y-A(B) SEL1-KFR26GW/Y-A(B) ROO M T E P E R AT R E M U S ESOR N P IP E TE MP ER AT UR E SE NS OR D IS PL AY B OA RD STEP MOTOR POWER SUPP LY BROWN 1 35 1 35 CN6 BLUE BLACK CN11 COMPRESSOR RELAY 13 13 EL-KFR36GW/Y-A(B) EL1-KFR20GW/N2Y-A(B) SEL1-KFR36GW/Y-A(B) INDOOR MOTOR Y/G 321 321 CN4 1 2 3 45 12345 CN12 21 21 CN2 21 21 CN3 RED CN 5 8 7 6 5 4 3 21 YELLOW BLUE C N1 5 C N1 3_2 C N1 3_1 CN1 1 1 3 3 Y/G JX1 1 2(N) 3 4 INDOOR UNIT TO OUTDOOR UNI T TRANSFORMER 26 DIS PL A Y B A RD O GD Midea Refrigerant Equipment Co. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EXS12HC1WI




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX EXS12HC1WI will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.