User manual AEG-ELECTROLUX ETN1061V

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG-ELECTROLUX ETN1061V. We hope that this AEG-ELECTROLUX ETN1061V user guide will be useful to you.


AEG-ELECTROLUX ETN1061V : Download the complete user guide (241 Ko)

You may also download the following manuals related to this product:

   AEG-ELECTROLUX ETN1061V (237 ko)
   AEG-ELECTROLUX ETN1061V (238 ko)

Manual abstract: user guide AEG-ELECTROLUX ETN1061V

Detailed instructions for use are in the User's Guide.

[. . . ] If possible, remove the product from the window before the hurricane arrives. There is risk of property damage, failure of product, or electric shock. (Do not touch the electrostatic filter, if the unit is so equipped. ) There is risk of physical injury, electric shock, or product failure. When the product is soaked (flooded or submerged), contact an Authorized service center. [. . . ] Unit mm2 7k/9K 1. 0 12K 1. 5 8. 3 Pipe length and the elevation Capacity Btu/h 7k/9k 12k Pipe size GAS 3/8'' (9. 52) 1/2'' (12. 7) LIQUID 1/4'' (6. 35) 1/4'' (6. 35) Standard length (m) 5 5 Max. Length A (m) 10 10 Additional refrigerant (g/m) 30 30 In case that more than 5m. Caution: Capacity is base on standard length and maximum allowance length is base of reliability. Oil trap should be installed per 5-7 meters. 11 Service manual 8. 4 Air purging of the piping and indoor unit Required tools: Hexagonal wrench; adjustable wrench; torque wrenches, wrench to hold the joints and gas leak detector. If air remains in the refrigeration piping, it will affect the compressor, reduce the cooling capacity, and could lead to a malfunction of unit. Be sure, using a torque wrench to tighten the service port cap (after using the service port), so that it prevents the gas leakage from the refrigeration cycle. Procedure 1. Open the valve stem of the 2-way valve counterclockwise approximately 90', wait 10 seconds, and then set it to closed position. Set the 2-way valve to the open position and remove the cap from the 3-way valve's service port. Using the hexagonal wrench to press the valve core pin, discharge for three seconds and then wait for one minute. Use torque wrench to tighten the service port cap to a torque of 18n. m 6. At this time, especially check for gas leakage from the 2-way and 3-way stem nuts, and from the service port. Caution: If gas leakage is discovered in step (3) above, take the following measures. 10. 2. 4 Inverter module Protection, Inverter module Protection itself has a protection function against current, voltage and temperature. 10. 2. 5 Sensor protection at open circuit and breaking disconnection 10. 2. 6 Fan Speed is out of control. When Indoor Fan Speed is too high(higher than 2100RPM)or too low(lower than 300RPM), the unit stops and LED displays failure information and can't return to normal operation automatically. If there is no Cross Zero signal in 4 minutes, the unit stops and LED displays failure information and can't return to normal operation automatically. 9. 3 Fan-only mode The compressor4-way valve and outdoor fan is off at fan-only mode. Fan speed can be selected as high/mid/low/ auto. 9. 4 9. 4. 1 9. 4. 2 Cooling mode The 4-way valve is closed at cooling mode. Action of compressor at cooling mode: compressor must run for 7 minutes after starting and then judge the difference between setting temperature and room temperature. 3. 5 3. 0 2. 5 2. 0 1. 5 1. 0 0. 5 -0. 5 -1. 0 A B C D E F G H 18 Service manual 9. 4. 3 Auto fan at cooling mode: Condition T=Indoor Temp. -Setting Temp. down 9. 4. 4 Anti-freezing control to indoor evaporator at cooling mode( T: evaporator temp. 0<T< 4 T< 0 Compressor Decrease frequency of compressor Off 9. 4. 5 Rated capacity test Set mode to cooling mode Set temp. to 17° C Set fan speed to high speed Press economy button on remoter controller After running for 5 hours, the rated capacity testing will be cancelled. 9. 5 9. 5. 1 9. 5. 2 9. 5. 3 Dehumidifying mode The 4-way valve is off. The indoor fan is fixed in breeze speed The action of compressor follows the rules below; Room temp. --setting temp. [. . . ] is lower than 0, Defrosting starts when meeting one of the following conditions, a. The temperature of outdoor heat exchanger remains consecutively lower than 3° for more c than 40 minutes, and the temperature remains consecutively -6° for more than 3 minutes, c b. The temperature of outdoor heat exchanger remains consecutively lower than 3° for more c than 40 minutes, and the temperature remains consecutively -6° for more than 3 minutes, c c. The temperature of indoor unit pipe decreases 5°c than before 9. 7. 1. 3 The temperature of outdoor heat exchanger remains consecutively lower than 3° for more c than 120 minutes, and the temperature remains consecutively -2° for more than 3 minute s c 9. 7. 2 Ending condition of defrosting If one of following conditions is satisfied, end the defrosting and turn into heating mode: a. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX ETN1061V




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX ETN1061V will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.