User manual AEG-ELECTROLUX EFC9466X/S

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG-ELECTROLUX EFC9466X/S. We hope that this AEG-ELECTROLUX EFC9466X/S user guide will be useful to you.


AEG-ELECTROLUX EFC9466X/S : Download the complete user guide (440 Ko)

You may also download the following manuals related to this product:

   AEG-ELECTROLUX EFC9466X/S (435 ko)

Manual abstract: user guide AEG-ELECTROLUX EFC9466X/S

Detailed instructions for use are in the User's Guide.

[. . . ] The hood should not be used by children or persons not instructed in its correct use. MAINTENANCE Switch off or unplug the appliance from the mains supply before carrying out any maintenance work. Clean the hood using a damp cloth and a neutral liquid detergent. 650 mm min. EN 5 5 CHARACTERISTICS Dimensions 650 min. Components Ref. 1 Q. ty Product Components 1 Hood Body, complete with: Controls, Light, Blower, Filters 2 1 Telescopic Chimney comprising: 2. 1 1 Upper Section 2. 2 1 Lower Section 9 1 Reducer Flange 150-120 mm 14. 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref. [. . . ] Place bracket 7. 2. 1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line. Place bracket 7. 2. 1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line. Mark a reference point as indicated at 116 mm from the vertical reference line and 330 mm above the horizontal reference line. Fix the lower bracket 7. 2. 1 using the 12a screws (4, 2 x 44, 4) supplied. Fix the upper bracket 7. 2. 1 and the air outlet connection support 7. 3 together using the 2 screws 12a (4, 2 x 44, 4) supplied. Insert the two screws 12a (4, 2 x 44, 4) supplied in the hood body fixing holes, leaving a gap of 5-6 mm between the wall and the head of the screw. 650 min. 330 X 7. 2. 1 EN 7 7 Mounting the hood body Before attaching the hood body, tighten the two screws Vr located on the hood body mounting points. Adjust screws Vr to level the hood body. Vr 12a Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe 150 or 120 mm, the choice of which is left to the installer. To install a 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet. Fix the pipe in position using sufficient pipe clamps (not supplied). Remove any activated charcoal filters. 150 9 120 RECIRCULATION VERSION AIR OUTLET Put connection 15 into the connection support 7. 3. In case the hood is set to the intensive speed directly from OFF-state it will then start from the first speed after 5 minutes of intensive speed. Touch control lit Metal grease filters satuWhen pressed for 4 seconds it resets the filter alarm ration alarm. This procedure can be carried out only when the The alarm starts up after motor is stopped. Flashing touch control 100 working hours. (Activation; check the paragraph "Odour filter") EN 1 11 1 MAINTENANCE Grease filters CLEANING OF THE METAL CASSETTE FILTERS Alarm reset Stop the motor. Press the F -touch control for at least 4 seconds until the T1 -touch control flashes. They need to be washed every 2 months or even more frequently in case of particularly intensive use of the hood. Remove the filters one by one pushing them towards the back side of the unit and simultaneously pulling downwards. Any kind of bending of the filters has to be avoided when washing them. Before fitting them again into the hood make sure that they are completely dry. When fitting the filters into the hood pay attention that they are mounted in correct position and that the handle faces outwards. EN 1 12 2 Odour filter (Recirculation Version) This filter cannot be washed or regenerated, and must be replaced when the F touch control starts to flash, or at least once every 4 months. [. . . ] Enabling/Disabling the alarm signal In Recirculation Version Hoods, the Filter saturation Alarm must be enabled at the time of installation or later. Disconnect the mains power supply to the hood by removing the motor unit power supply cable connector, switching off the power supply at the Mains or turning the Main switch off. Release the touch control, touch controls L, T2 and F will light up normally. Within 3 seconds press the touch control F until the key itself flashes to confirm as follows: 2 flashes Charcoal odour Filter saturation Alarm ENABLED 1 flash - Charcoal odour Filter saturation Alarm DISABLED REPLACING THE CHARCOAL ODOUR FILTER Reset the alarm signal Stop the motor. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EFC9466X/S




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX EFC9466X/S will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.