User manual AEG-ELECTROLUX DF6861M

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG-ELECTROLUX DF6861M. We hope that this AEG-ELECTROLUX DF6861M user guide will be useful to you.


AEG-ELECTROLUX DF6861M : Download the complete user guide (581 Ko)

Manual abstract: user guide AEG-ELECTROLUX DF6861M

Detailed instructions for use are in the User's Guide.

[. . . ] 65 Extraction mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Recirculation mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Maintenance and Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · The ducting must be fire retardant, 120mm in diameter and the length should be no more than: 3 metres with one 90 degree bend 2 metres with two 90 degree bends Bends of more than 90 degrees will reduce the efficiency of the hood and reduce the airflow. · Failure to observe these basic instructions will drastically reduce the performance and increase the noise levels of the extractor hood. 64 Description of the Appliance · The cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam. · The hood is supplied as an extractor unit and can also be used with a recirculation mode by fitting a charcoal filter. The hood, therefore, can be used immediately in the recirculation mode. We advise removing the charcoal filter to use the hood in the extraction mode. Extraction mode · In this version fumes are extracted to the outside via a hose. · In order to obtain the best performance the hose should have a diameter equal to the outlet hole. Recirculation mode · The air is filtered through a charcoal filter and returned to the kitchen. · You will need an original charcoal filter for the recirculation function. 1 A = ON/OFF switches (Motor, light) B = Grease filter C = Light D = Control panel E = Visor (Removable) 65 Control Panel · The switches are mounted on the upper right side of the visor (Fig. The numbers and symbols have the following meanings (from left to right): CHDF 6260 -ML/GB - PNC 942 120 679 DF 6260 -ML/AUS - PNC 942 120 712 DF 6260 -ML - PNC 942 120 645 DF 6260 -ML/1 - PNC 942 120 820 DF 6160 -ML - PNC 942 120 644 = Continuously variable fan control = Intensive setting = Light = Light OFF = Light ON 1 2 3 4 = = = = fan set 1 fan set 2 fan set 3 fan set 4 = Light = Light OFF = Light ON The fan is controlled by moving the sliding switch. The extractor part (visor) of the hood is used to switch the fan on and off when the appliance is switched on (Motor). When the visor of the appliance is withdrawn, the fan automatically switches on. After approximately three years of use, the charcoal filter should be replaced with a new, as the odour reduction capacity will be reduced. Insert the charcoal filter into the lugs of the frame above using the 2 red clips to retain it, press the red clips inwards, and insert the charcoal filter in the frame. Press both red lugs upwards (towards the inside of the housing) and remove the charcoal filter downwards. Clean the internal housing only with warm washing-up liquid' suds (never use any abrasive cleaners, brushes, or scouring agents). · Always specify the hood model code number and serial number when ordering replacement filters. This information is shown on the registration plate located on the inside of the unit. · The charcoal filter can be ordered from your local Service Force Centre. Fig. 3 68 Warning · Failure to observe the instructions on cleaning the unit and changing the filters will cause a fire hazard. · The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations. Changing the light bulb(s) · Disconnect the unit from the mains power supply. · Unlock the lighting cover (D) by twisting the bolts to the left and fold down the bulb cover. · Close the bulb cover and relock it by twisting the bolts to the right. [. . . ] Ø 100 mm exhausting pipe: apply the adapter on the flange. A Fig. 10 75 Spice rack · If a spice rack is to be incorporated in front of the hood, a minimum distance of 5 mm must be provided between the front edge of the fume extractor hood and the spice rack wall (this air gap being necessary for air circulation). · The upper part of the spice rack rear wall should be detachable (access for exhaust air hose or adjustment of furniture housing). Installing the extractor hood in the wall unit - extraction version (Recirculation version with charcoal filter) · Fix the drilling template to the inside wall of the wall unit on the right and left sides, and mark out and predrill Ø 2 mm mounting holes as well as 2 x Ø 6 mm - 5 mm depth holes for the mounting claws (installation aids). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX DF6861M




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX DF6861M will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.