User manual ADEMCO VISTA-15PSIA PROGRAMMING GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ADEMCO VISTA-15PSIA. We hope that this ADEMCO VISTA-15PSIA user guide will be useful to you.


ADEMCO VISTA-15PSIA PROGRAMMING GUIDE: Download the complete user guide (382 Ko)

Manual abstract: user guide ADEMCO VISTA-15PSIAPROGRAMMING GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems Programming Guide K5305-1PRV5 10/04 Rev. A TO ENTER PROGRAMMING MODE (using an alpha keypad connected to the control): A. POWER UP, then press [] and [#] at the same time, within 50 seconds of powering up (this method must be used if 98 was used to exit program mode). Command/Explanation Press [] + [Field Number], followed by the required entry. [. . . ] To disable the report code for this zone, enter 00. 58 Expert Zone Programming Mode (press 58 while in Data Programming mode) SET TO CONFIRM? Select whether you want confirmation of wireless device enrollment. (See "XMIT TO CONFIRM" prompt later in this section. ) We recommend that you confirm the programming of every transmitter. HARDWIRE TYPE Appears only for zones 02-08. Enter the desired hardwire type: 0 = EOL; 1 = NC; 2 = NO; 3 = zone doubling (ZD); 4 = double-balanced (DB) ( VISTA-20P) SUMMARY SCREEN Zn ZT P RC HW: RT 01 09 1 10 EL 1 (Typical for Zone 1, initial summary screen) RESPONSE TIME For hardwired zones 01-08. Enter the desired response time for this zone: 0 = 10mSec; 1 = 350mSec; 2 = 700mSec; 3 = 1. 2 secs (see field 174). NOTE: If zone doubling is being used, the response time selected for zones 02-08 automatically applies to each zone's associated doubled zone. INPUT TYPE Skipped for zones 2-8, and for zones 10-16 if zone-doubling enabled. Enter the input type: 2 = AW (Aux wired zone); 3 = RF (supervised RF); 4 = UR (unsupervised RF); 5 = BR (unsupervised button type) NOTE: To change the input type of a previously programmed wireless device to a wired zone, you must first delete the transmitter's serial number. Zn ZT P RC IN: L 10 00 1 10 RF: ­ (Typical for entered zone number; zone 10 in this example) System displays summary of zone 1's current programming. A summary screen for that zone is displayed, along with any current programming values, and the cursor moves to the Zone Type location. The cursor then automatically moves to the next locations after each entry is made. Special Function Keys: · [A] (Advance) and [B] (Back) keys on the keypad move the cursor within the screen. · [C] (Copy) key will insert the previous zone's attributes, if desired. · [D] key starts the Wireless Key Programming Templates menu (see Wireless Key Programming Templates section that follows this section). Sequentially enter Zone Type (ZT), Partition (P), and Report Code (RC), then Hardwire Type (HW) and Response Time (RT) for basic wired zones 1-8 or Input Device Type (IN) for zones 9 and higher (Loop Number [L] is programmed at the INPUT S/N prompt). See *56 Zone Programming Menu Mode section described earlier for entry values. · For wireless devices (input types RF, UR, BR), continue to the INPUT S/N (serial number/loop number) and XMIT TO CONFIRM prompts described earlier in the *56 Zone Programming Menu Mode section. When done, the display returns to the initial summary screen prompt to let you program the next zone. · For wired devices, the display returns to the initial summary screen prompt to let you program the next zone. To Quit, enter 00 at the zone number location and press []. INPUT S/N Enroll the transmitter's serial number and loop number as follows: 1. Transmit two open/close sequences (for button-type transmitters, press and release the button twice, waiting about 4 seconds before pressing the button the second time). Manually enter the 7-digit serial number printed on the label of the transmitter. Press the [] key to move to the "L" position, then enter the loop number. Use the [A] (Advance) and [B] (Back) keys to move the cursor forward and back within the screen. Pressing the [C] (Copy) key will insert the previously enrolled serial number, if desired (used when programming a transmitter with several input loops). [. . . ] 2000 OHMS EOLR ZONE 6 VISTA-20P ONLY GREEN: DATA IN FROM KEYPAD RED: KEYPAD PWR ( + ) YELLOW: KEYPAD DATA OUT 165 Eileen Way, Syosset, NY 11791 Copyright © 2003 Honeywell International Inc. THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION'S STANDARD 72, CHAPTER 2 (NATIONAL FIRE PROTECTION ASSOCIATION, BATTERY-MARCH PARK, QUINCY, MA 02269). PRINTED INFORMATION DESCRIBING PROPER INSTALLATION, OPERATION, TESTING, MAINTENANCE, EVACUATION PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH THIS EQUIPMENT. CAN BE USED FOR 2-WIRE SMOKE DETECTORS K5305-1PRV5 10/04 Rev. SEE INSTRUCTIONS. BATTERY FUSE 3A FOR REPLACEMENT, USE SAME VALUE (e. g. 90-12) RELAY PROGRAM RELAY AS ZONE TYPE 54 (FIRE ZONE RESET) _4 BLK _ + RED BATTERY CAPACITY FOR EMERGENCY BURGLARY STANDBY USE AT LEAST 4 HRS 8-PIN CONNECTOR USED FOR 1361X10 TRANSFORMER CONNECTIONS AND FOR ON-BOARD TRIGGERS SEE INSTRUCTIONS. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ADEMCO VISTA-15PSIA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ADEMCO VISTA-15PSIA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.