User manual ADDONICS RR2035RPHML
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ADDONICS RR2035RPHML. We hope that this ADDONICS RR2035RPHML user guide will be useful to you.
Manual abstract: user guide ADDONICS RR2035RPHML
Detailed instructions for use are in the User's Guide.
[. . . ] RAID Rack Overview
Mounting Holes Top Cover System Reset
Power Switch
Addonics
TECHNOLOGIES
RAID Rack
Mounting Holes
Buzzer Reset
LED Display
RR2035RPHES, RR2035AXHES, RR2035RPHML, RR2035AXHML
4 5SA disk array
th
Fans
User's Guide
Power Supply 4 eSATA ports
Power Switch: This is the switch to power on devices connected to the power supply. Note: The main power switch located at the back of the enclosure must be turned on first. Buzzer Reset: Pressing the button stops the buzzer from making a sound. [. . . ] The power and HDD access LED (D7 D11) goes off.
Floppy Power Connector
Reset Switch Connector
Ambient Detect Terminal
Fan, temperature and power LED connectors
Fan detect Selection
Temp. Setting o o o (40 C, 50 C, 60 C)
Features:
Fan1 to Fan8 could be set either "ENABLE" or "DISABLE". When all the fans are set on "DISABLE", the Fan LED will have no light on. When Ambient temperature (or temperature inside the storage rack) is over the set temperature, the LED will flash and the buzzer will sound.
Hardware Port Multiplier mounted inside the RAID Rack
Floppy power connector SATA host port
J1 Drive Activity LED H Activity LED for eSATA host port lights up when it is connected to a SATA controller card. D0, D1, D2, D3 & D4 - Activity LEDs for port 1, 2, 3, & 4 light up when a drive is connected and blinks when there's drive activity. J3 Error LED H error LED for eSATA host port D0, D1, D2, D3 & D4 - error LED for port 1, 2, 3 & 4
buzzer SATA port 5 SATA port 4 SATA port 1 RAID setting jumper block (J4)
Two Options for Setting RAID on the 5-port HPM-XA
(only select one option) I. Using the JMicron HW RAID Manager utility program For Windows users, install the JMicron HW RAID Manager located on the SATA Controller CD. This manager can be use to create and monitor the status of the RAID volume.
SATA port 3 SATA port 2 Error and drive activity LED jumper block (J1, J3)
Use the default factory RAID jumper setting when using the JMicron HW RAID Manager.
J4 RAID Setting Jumper Block II. BZS Error buzzer function SET RAID mode setting EZ Automatic rebuilding to M2 RAID mode 2 M1 RAID mode 1 M0 RAID mode 0 Using the onboard RAID setting jumper block (Complete the 7 steps below) Recommended to be used on operating system without JMicron HW RAID Manager support like Linux, Mac & Solaris. (ignore EZ pins, EZ is DISABLED)
spare drive
Default factory RAID jumper setting
1. 4.
Error buzzer function is DISABLED (BZS) RAID mode setting modification is DISABLED (SET) Auto-rebuilding to spare drive is ENABLED (EZ) Individual drive mode is ENABLED (M0~M2)
2. 4.
Note: When the default factory RAID setting is used, independent drive configuration is supported only when connecting to controllers with Silicon Image Sil3124, Sil3132 chip set or controllers that are Port Multiplier (PM) compatible. LED Pin header
Turn on the system power where the HPM is connected for at least 5 seconds for hardware initialization. On the J4 RAID setting jumper block, change (M0~M2) jumper setting to the desired RAID mode using the diagram on the next page as reference. All settings on the diagram shows RAID mode setting modification is ENAABLED (SET) Error buzzer function is DISABLED (BZS)
B. Or to the diagram below where buzzer is ENABLED.
Note: On the setting where buzzer is ENABLED, there is NO jumper on SET. [. . . ] Default setting
Notes on RAID Auto rebuild (Diagram shows default factory RAID jumper setting) In reference to the diagram, auto-rebuilding is ENABLED (EZ) When EZ mode is ENABLED, the degraded RAID group will start rebuilding automatically when you install a good drive to replace the failed drive.
Cable Connections For Model: RR2035RPHES & RR2035AXHES 1. Connect one end of the eSATA cable to the eSATA port on the RAID Rack and the other end to the eSATA port on your system.
7.
For Model: RR2035RPHML, RR2035AXHML 1. Attach one end of the infiniband cable to the multilane port on the RAID Rack and the other end to the multilane port on your system. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ADDONICS RR2035RPHML
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ADDONICS RR2035RPHML will begin.