User manual ADDONICS CRC4HESU

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ADDONICS CRC4HESU. We hope that this ADDONICS CRC4HESU user guide will be useful to you.


ADDONICS CRC4HESU : Download the complete user guide (115 Ko)

Manual abstract: user guide ADDONICS CRC4HESU

Detailed instructions for use are in the User's Guide.

[. . . ] To ensure there is a spare key, your Cipher tower comes with 4 pairs of Cipher keys. These cipher keys have all identical encryption code unless you requested then to be coded differently. One of these keys should be kept in a safe and secure location and can be sent back to Addonics for duplicating additional keys. [. . . ] Once you proceed to partition the drive, the data that was on the hard drive will be erased and cannot be recovered. a. b. c. Power Switch I. Installing drives into the Cipher Tower (LED 4) HPM Health (LED 2) USB Status Power LED Refer to Ruby Cipher enclosure hard drive installation guide Open the front panel of the Cipher tower. Slide the enclosure into the drive bay. RAID setting button RAID config rotary switch USB port eSATA port (LED 3) HPM Power (LED 1) eSATA Status ADDONICS TECHNOLOGIES Model: CRC4HESU 4. LED Information: When power switch is turned on, the green LED lights up. eSATA status LED: When eSATA port is used to connect to a system, the LED lights up. USB status LED: When USB port is used to connect to a system, the LED lights up. Power LED: For security purposes, remove the cipher keys from the Cipher tower after the drives are detected by the system. All the files being transferred into the drives are still encrypted even if the cipher key is removed. When the Cipher tower is restarted, the 4 cipher keys must be inserted again in order to gain access to the drives. 5. V. Instruction for Special RAID Modes: III. Insert the 4 AES 256-bit cipher keys into each cipher keyhole on the Ruby Cipher enclosures located at the front of the Cipher tower. BIG 2 - 2 Drives Spanned o Note: Do not connect more than 2 SATA drives to the hardware port multiplier. o For SATA drives with different capacities, the hardware port multiplier will use the smallest drive capacity of the 2 drives connected to create the total partition size. FAST 2 - 2 Drives Striped o Note: Do not connect more than 2 SATA drives to the hardware port multiplier. Verify RAID Setting on the Cipher tower Cipher keyhole Note: Disconnect the Cipher tower from computer when verifying the RAID setting. It is assumed that you have already connected the SATA drives and set up the raid mode when verifying the raid setting. The selected LEDs will light up for 2 seconds followed by a blink and cycles back. RAID Mode BIG 2 BIG 4 FAST 2 FAST 4 SAFE FAST SAFE 2 RAID 3 + S RAID 5 + S LEDs LEDs 1, 2 & 4 all OFF 4 ON, 2 & 1 OFF 2 ON, 4 & 1 OFF 1 ON, 4 & 2 OFF 4 & 2 ON, 1 OFF 4 & 1 ON, 2 OFF 2 & 1 ON, 4 OFF 4, 2 & 1 all ON b. [. . . ] Insert the 4 AES 256-bit cipher keys into each cipher keyhole on the Diamond Cipher enclosures located at the front of the Cipher tower. Observed that the green Cipher power LEDs at the front of the Cipher tower are on. If they did not, reinsert the cipher keys and re-power the Cipher tower. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ADDONICS CRC4HESU




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ADDONICS CRC4HESU will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.