User manual ACT ENTRY A10

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ACT ENTRY A10. We hope that this ACT ENTRY A10 user guide will be useful to you.


ACT ENTRY A10 : Download the complete user guide (580 Ko)

Manual abstract: user guide ACT ENTRY A10

Detailed instructions for use are in the User's Guide.

[. . . ] This is a 1 Amp Power Supply Unit ACTentryA10VR-FK ACTentryA10VR-S ACTentryA10VR-F ACTentry A10 Intercom Handset ACTentry 1A PSU 2 ACTentry A10 Operating and Installation Instructions ACTentry A10 Schematic 3 ACTentry A10 Operating and Installation Instructions Quick Programming Guide (For typical System) 1. Change User 1 Code On the digital keypad: Press Button 0, then Press Button 1 (for User 1). Change Programming code On the digital keypad: Press Button 0, then Press Button . Note: The ACTentry A10 may be returned to its factory default condition at any time by entering the programming mode and pressing button three times. For Door 2 Operation 1. [. . . ] When the door is toggled open, this will be For example, to set user 1 to toggle the door open/locked: Enter 1(set outputs), followed by 1(user1), followed by 0(Toggled). (e. g -9999-1-1-0- ) To set user 2 to open Door 2: Enter 1(set outputs), followed by 2(user2), followed by 2 (Door 2 timed) (e. g. -9999-1-2-2- ) Setting timers: (From programming mode) Enter 2 (Set Timers 0-4 (Timer number) {Buzzer sounds indicating timing. . . wait required period} (Stop timing) {Buzzer stops ­ timer set} 6 ACTentry A10 Operating and Installation Instructions Timer No. 0 1 2 3 4 Function Relay time Door 2 / Output 2 time Output 3 time Door Ajar time Guest Buzzer time Default 5s 5s 5s 30s 2s Timers may be set to any duration between 2 seconds and 4 minutes. Setting Configuration: (From programming mode) Enter 30-37 or 40-47 0-1 (Option number) (1= Set, 0 = Unset) Option 30 31 32 33 Function Door Chime Default Off Off On Off Operation When set, whenever the door contact is opened, the built-in buzzer makes a chime sound and the buzzer output activates for 2 seconds. When set, the keypad operates silently, that is no audible tones (key-presses or confirm tones) are produced from the built-in buzzer function (function 0). This option will override option 42 (Auto backlighting) When set, and when the relay is active (following a valid code or buttonr elease), the relay timer is truncated to 2 seconds when the door contact opens. This ensures that irrespective of programmed relay time, the door will be locked as soon as it closes, and any person following will have to enter a code. When set, the keypad may be used as a remote keypad for an alarm system. The red and green indicators are controlled by the door contact and the release button inputs inputs respectively, and the built in buzzer is controlled by the interlock input. When set, two or more keypads may be interlocked so that only one controlled door may be open at any one time. The interlock output is active whenever the relay is active or when the door contact is open. When the interlock input is active the release button and all codes are inactive, and the red indicator flashes. The interlock outputs and inputs of any number of keypads may be combined on a single wire. When set, all user codes, and the programming code, are six digits long. The default user one code becomes 123456 and the default programmer code becomes 999999. When set, two different codes must be entered within 15 seconds in order to open the door. The outputs activated are those which have been programmed for the first code to be entered. Silent Operation Permanent Backlighting Locksaver (Anti Tailgating) 34 Alarm Keypad Operation Interlock Off 35 Off 36 Six Digit Codes Codes Twin Codes Off 37 Off 7 ACTentry A10 Operating and Installation Instructions Option 40 Function Door Forced Alarm Group Disable Default Off Operation When set, the buzzer output is activated, if the door contact opens when a valid code has not been entered. When set, the top five user codes (5-9) are inactive any time the interlock input is activated. When set, the keypad illumination is normally off, but will switch on in response to any key being pressed or while in programming mode. [. . . ] If you do not feel your system is working at an optimum level please review the following prior to contacting our Technical Support Helpdesk. Low Volume through the Speaker Grill on the Door Entry Panel Please check the following: 1. Ensure that the Speaker Grill is fitted securely against the Door Entry Panel Grill. 9 ACTentryA10 Operating and Installation Instructions T y p i c a l A C Te n t r guration (Energised Lock) Run O and R as twisted-pair Door Intercom Handset (base of) 0V +V I RO T Z Volume A Adjust Volume B Adjust Speech Unit ACT 10 Keypad LK1 OMRON Door Release Button 5A 0V Interlock (PB2) Push Button Door Contact INPUTS TAMPER Volt-Free Tamper Contacts (Rear View) CHROT I RO T Z Call Button A maximum of 4 Door Intercom Handsets per Door Entry Panel +V + N/C C +V 0V Power Supply 12 V AC / DC 12 AC/DC OMRON 250V AC 5A 30VDC 5A 0 V A C 25 5A 30VDC N/O OUTPUTS 0V Buzzer OP3 Duress OP2 Interlock N/O C N/C Important! [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ACT ENTRY A10




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ACT ENTRY A10 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.