User manual ACT ACTSMART PRODUCT RANGE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ACT ACTSMART PRODUCT RANGE. We hope that this ACT ACTSMART PRODUCT RANGE user guide will be useful to you.


ACT ACTSMART PRODUCT RANGE : Download the complete user guide (729 Ko)

Manual abstract: user guide ACT ACTSMART PRODUCT RANGE

Detailed instructions for use are in the User's Guide.

[. . . ] ACTSmart Standalone wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ACTSmart Network wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ACTSmart Flush mounting diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ACTSmart Surface mount diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] This setting only applies to a Networked System (see Programming a Network System). -6- ACTSmart Operating and Installation Manual Rev 1. 1 Adding a Card Batch: Step Keypad Entry 1 10 2 Present Card 3 Present Card 4 Enter 1-8, (optional)* 5 Press Deleting a Card Batch: Step Keypad Entry 1 11 2 Present Card 3 Present Card 4 Enter 1-8, (optional)* 5 Press Adding a PIN: Step Keypad Entry 1 12 2 0001-9999 3 1-8, (optional)* 4 Press Deleting a PIN: Step Keypad Entry 1 13 2 0001-9999 3 1-8, (optional)* 4 Press Adding a Card and PIN: Step Keypad Entry 1 14 2 Present Card 3 0001-9999 4 1-8 (optional)* 5 Press Deleting a Card and PIN: Step Keypad Entry 1 15 2 Present Card 3 1-8, (optional)* 4 Press Operation Add Card Batch First card in Batch (lowest number card) Last Card in Batch (highest number card) Select each door this batch enabled for End programming card batch ­ Note: the buzzer will sound while cards are loaded into memory. Operation Delete Card Batch First card in Batch (lowest number card) Last Card in Batch (highest number card) Select each door this batch deleted from End delete card batch­ Note: the buzzer will sound while cards are deleted from memory. Operation Add PINs (Make sure Option 40 is set on PIN and Prox units. ) 4 - 8 digit PIN code Select each door this PIN is valid for End programming PINs Operation Delete PINs 4 - 8 digit PIN code Select each door this PIN is deleted from End deleting PINs Operation Add Card and PIN (Make sure Option 39 is set on PIN and Prox units. ) 4 - 8 digit PIN code Select each door this Card & PIN is valid for End programming Card and PINs Operation Delete Card and PIN Select each door this Card & PIN is deleted from End deleting Card and PINs -7- ACTSmart Operating and Installation Manual Rev 1. 1 Adding a Card Batch using the keypad: Step Keypad Entry Operation 1 16 Add Card Batch 2 Enter 10-digit card number 10-digit First Card number with leading zeros. 3 Enter 10-digit card number Second Card number 4 1-8, (optional)* Select each door this Card is deleted from 5 Press End Adding Card Batch Deleting a Card or Card and PIN using the keypad: Step Keypad Entry Operation 1 17 Delete Card or Card and PIN 2 Enter 10-digit card number 10-digit Card number with leading zeros. 3 1-8, (optional)* Select each door this Card is deleted from 4 Press End deleting Card (Card and PIN) Set Door Relay Time: Step Keypad Entry 1 20 2 Enter 3 digit time 3 1-8 (optional)* 4 Press Set Door Ajar Time: Step Keypad Entry 1 21 2 Enter 3 digit time 3 1-8 (optional)* 4 Press Set Guest Buzzer Time: Step Keypad Entry 1 22 2 Enter 3 digit time 3 1-8 (optional)* 4 Press Change Programming Code: Step Keypad Entry 1 23 2 0001-9999 Operation Set Door Relay Time ­ (default 5 seconds) 000-255 seconds ­ (leading zeros required). Select each door this timer is set for End setting Door Relay Timer Operation Set Door Ajar Time ­ (default 30 seconds) 000-255 seconds ­ (leading zeros required). Select each door this timer is set for End setting Door Ajar Time Operation Set Guest Buzzer Time ­ (default 2 seconds) 000-255 seconds ­ (leading zeros required). Select each door this timer is set for End setting Guest Buzzer Time Operation Change Programming code New 4 - 8 digit programming code Change Number of PIN Digits: Step Keypad Entry Operation 1 24 Change Number of PIN digits 2 4-8 Select number of PIN digits in range 4 to 8. This mode allows all users to have a common PIN code to use with their cards. -9- ACTSmart Operating and Installation Manual Rev 1. 1 Setting Programmable Input Function: Step Keypad Entry Operation 1 50 Set Input Function (5 ­ Door Release button is default) 2 0-5 Select I/O Function Code (see below for explanation of codes) 3 1-8 (optional)* Select each door this function is valid for 4 Press End programming Input Function Setting AUX I/O 1 Function: Step Keypad Entry 1 51 2 0-9 3 1-8 (optional)* 4 Press Setting AUX I/O 2 Function: Step Keypad Entry 1 52 2 0-9 3 1-8 (optional)* 4 Press Operation Set AUX I/O 1 Function (0 - Door Contact is default) Select I/O Function Code (see below for explanation of codes) Select each door this function is valid for End programming AUX I/O 1 Operation Set AUX I/O 2 Function (7 - Door Alarm is default) Select I/O Function Code (see below for explanation of codes) Select each door this function is valid for End programming AUX I/O 2 I/O Function Codes: Code Function 0 Door Contact 1 Fire Alarm Override 2 3 4 5 6 7 8 9 Lock Door Card and PIN Card or PIN Door Release Button Interlock Door Alarm Follow Buzzer Operation Input required if you wish to monitor Door Forced or Door Ajar When this input is high, the door is opened and the green LED flashes (See Fire Alarm Override Connections diagram). If this is wired into the Master Smart, then all doors on the network will open. When this input is low, the door locks and the red LED flashes When this input is low, then only users who enter both Card and PIN will be admitted. When this input is low, a valid Card or a valid PIN will open the door. This normally behaves as an input and locks the door while the input is low. While the door relay is active or the Door Contact is open, it becomes an active output. This output activates while an alarm is present ­ A door alarm may be a door forced, door ajar, tamper or duress. This output activates for Door Chime or Door Alarms - 10 - ACTSmart Operating and Installation Manual Rev 1. 1 Quick IO Setup: Step Keypad Entry 1 53 2 0-9 0 1 2 3 4 5 6 7 8 9 3 4 1-8 (optional)* Press Operation Set Input Output Functions (0 ­ is default) Select a code Prog Input AUX IO 1 Door Release Button Door Contact Door Release Button Door Contact Door Release Button Door Contact Door Release Button Card And PIN Door Release Button Fire Override Door Contact Follow Door Contact Follow Door Contact Door Alarm Fire Override Interlock Card And PIN Interlock Select each door this function is valid for End Quick IO setup AUX IO 2 Door Alarm Buzzer Interlock Interlock Interlock Door Alarm Buzzer Buzzer Buzzer Follow - 11 - ACTSmart Operating and Installation Manual Rev 1. 1 Programming a Network System Up to 8 ACTSmart devices can be connected on the network. See the ACTSmart Network Installation diagram to complete the necessary connections. Programming Door Numbers To allow some users through a door and prevent access to other users, each ACTSmart on the network must be given a door number (1-8). An ACTSmart Proximity Only Unit requires a door number if it is to be programmed with advanced options. This device will be used for programming the entire network and should be a PIN and Prox unit. The other ACTSmarts on the network (door numbers 2-8) are referred to as Slave Units. No programming is allowed on a Slave (except to default it ­ see Restoring Factory Defaults). The rest of the units on the network are assigned door numbers by following the procedure below: Assign Door Numbers: Step Keypad Entry 1 60 2 3 4 5 Operation Assign Door Numbers Any ACTSmart units without a door number start to beep. The number of beeps is determined by the door number to be programmed. [. . . ] If 0V is removed, the doors open. T amper In this case AUX I/O 1 is programmed as Fire Alarm Override (see page 10). A ux I /O 1 Note: To program the Fire Alarm Override and the Interlock, please refer to page 10 of the manual. ACTSmart Interlock Connections Common the 0V line of each ACTSmart to avoid Ground Loop issues. B A T C H: S E R IA L 01X X -1 P R ODUC T : AC T S mart R E V 1. 3 NUMB E : 00X X X X R 0123456789 1A 125V AC 1A 30V DC 5A/250V ~AC 12V = DC 5A/250V ~AC SCHRACK 0V A SCHRACK B A A ux I /O 2 Programmable I nput 12V = DC 12DC 0V N/O COMM N/C DC Power Supply Unit B A A ux I /O 2 Programmable I nput A ux I /O 1 T amper A ux I /O 1 In this case AUX I/O 2 is programmed as Interlock (see page 10). Link the AUX I/O terminal, programmed for Interlock, on each ACTSmart. - 16 - OMR ON +12V 5A 250V AC 5 A 3 0 V DC In this case, when one ACTSmart opens the door, the door on the other ACTSmart is locked and prevents access. OMR ON OMR ON +12V 5A 250V AC 5 A 3 0 V DC OMR ON Note: 0V line of ACTSmart system is connected to the common of the fire alarm panel relay. Common the 0V line of each ACTSmart to avoid Ground Loop issues. B A T C H: S E R IA L 01X X -1 P R ODUC T : AC T S mart R E V 1. 3 NUMB E : 00X X X X R B A T C H: S E R IA L 01X X -1 P R ODUC T : AC T S mart R E V 1. 3 NUMB E : 00X X X X R 0123456789 1A 125V AC 1A 30V DC 0123456789 12V DC 0V N/O COMM N/C +12V 0V DC Power Supply Unit T amper - 16 - B A T C H: S E R IA L 01X X -1 P R ODUC T : AC T S mart R E V 1. 3 NUMB E : 00X X X X R 0123456789 12V DC 0V N/O COMM N/C +12V 0V DC Power Supply Unit T amper ACTSmart Network Installation Diagram Note: When networking the ACTSmart units, common the 0V of each ACTSmart to avoid ground loop issues. Network cable is single shielded twisted pair, Belden 9501 or similar. T otal c able length maximum 1. 4km -17SHIE L D A B A 12V = DC 5A/250V ~AC 5A 250V AC 5 A 3 0 V DC Continue daisy-chain to remaining ACTSmart units on the network (maximum 8). A B B B A T C H: 01X X -1 P R ODUC T : AC T S mart R E V 1. 3 00X X X X SHIE L DS SHIE L D S E R IA L NUMB E : R B A T C H: 0123456789 S E R IA L NUMB E : R 01X X -1 P R ODUC T : AC T S mart R E V 1. 3 00X X X X 0123456789 1A 125V AC 1A 30V DC OMR ON OMR ON B B SCHRACK 12V = DC 5A/250V ~AC A ux I/O 2 A ux I/O 1 Programmable Input N/O COMM N/C SCHRACK A 12DC 0V +12V 0V DC Power Supply Unit A B B A A ux I/O 2 Programmable Input 12V DC 0V N/O COMM N/C +12V DC Power Supply Unit 0V T amper Do NOT use AC Power Supply. MUST be 12V or 24V DC. A ux I/O 1 T amper -17- ACTSmart Mounting Instructions for Flush-Mount Unit Standard pattress box. Spacers break away from main component when required by installer for use. View showing spacers stacking View showing mounting plate before spacers are broken Note: Determine the distance between the pattress box and the mounting plate, using the spacers which are labeled 1mm to 4mm. This allows the installer to make the required spacer length 1 to 10mm by stacking each spacer together. - 18 Magnet in mounting plate, which keeps tamper switch closed inside ACTSmart Screws Mounting plate is attached to the pattress box using the screws supplied. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ACT ACTSMART PRODUCT RANGE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ACT ACTSMART PRODUCT RANGE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.