User manual ACT ACTSMART

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ACT ACTSMART. We hope that this ACT ACTSMART user guide will be useful to you.


ACT ACTSMART : Download the complete user guide (857 Ko)

Manual abstract: user guide ACT ACTSMART

Detailed instructions for use are in the User's Guide.

[. . . ] Change Programming code Press 23, then enter new 4-digit programming code. Set Desired Door Relay Active Time Press 20, and then enter the desired number of seconds from 000-255 (three digits with leading zeros). Press button to complete. Note: The ACTsmart may be returned to its factory default condition at any time by entering the programming mode and pressing 80 followed by the button. For information on programming the advanced features and networking the ACTsmart range, please refer to the complete programming guide. Unit C1, South City Business Centre, Tel: 353-1-4662570 Fax: 353-1-4520427 UK Locall: 0845 300 5204 Web: http://www. accesscontrol. ie E-mail: sales@ accesscontrol. ie Copyright © 2008 Access Control Technology Ltd. [. . . ] When set, the buzzer output/ door alarm output is activated if the door contact opens when the door is locked. When set, and the door contact has been open for longer than the time programmed into the door ajar timer, the buzzer output/ door alarm output is activated. Closing the door and presenting a valid card or entering a valid PIN deactivates the output. When set, (default) and when the key on the keypad is pressed, the buzzer output is activated for the duration programmed in the guest buzzer timer. When set, and when a duress PIN is entered, the door is opened normally and the Door Alarm output activated. A duress PIN is any valid PIN with one added to last digit ie PIN code of 6799 would have a duress code of 6800. When the duress option is set, avoid using PINs that are different by 1. This mode allows all users to have a common PIN code to use with their cards. Option 30 31 Function Door Chime Silent Operation Default Off Off 32 Lock-saver (Anti Tailgating) Off 33 34 Toggle Door Forced Alarm Off On 35 Door Ajar Alarm On 36 Guest Button On 37 Duress Codes Off 38 39 40 41 Network Master Card and PIN Card or PIN Card and any PIN Off Off Off Off 9 ACTsmart Operating and Installation Manual Rev. 1. 2 Setting Programmable Input Function: Step 1 2 3 4 Keypad Entry 50 0-5 1-8 (optional)* Press Operation Set Input Function (5 - Door Release button is default) Select I/O Function Code (see below for explanation of codes) Select each door this function is valid for End programming Input Function Operation Set AUX I/O 1 Function (0 - Door Contact is default) Select I/O Function Code (see below for explanation of codes) Select each door this function is valid for End programming AUX I/O 1 Setting AUX I/O 1 Function: Step 1 2 3 4 Keypad Entry 51 0-9 1-8 (optional)* Press Setting AUX I/O 2 Function: Step 1 2 3 4 Keypad Entry 52 0-9 1-8 (optional)* Press Operation Set AUX I/O 2 Function (7 - Door Alarm is default) Select I/O Function Code (see below for explanation of codes) Select each door this function is valid for End programming AUX I/O 2 I/O Function Codes: Code 0 1 Function Door Contact Fire Alarm Override Operation Input required if you wish to monitor Door Forced or Door Ajar When this input is high, the door is opened and the green LED flashes (See Fire Alarm Override Connections diagram). If this is wired into the Master Smart, then all doors on the network will open. When this input is low, the door locks and the red LED flashes When this input is low, then only users who enter both Card and PIN will be admitted. When this input is low, a valid Card or a valid PIN will open the door. This normally behaves as an input and locks the door while the input is low. While the door relay is active or the Door Contact is open, it becomes an active output. This output activates while an alarm is present - A door alarm may be a door forced, door ajar, tamper or duress. This output activates for Door Chime or Door Alarms 2 3 4 5 6 Interlock Door Release Button Card or PIN Card and PIN Lock Door 7 8 9 Buzzer Follow Door Alarm 10 ACTsmart Operating and Installation Manual Rev. 1. 2 Quick IO Setup: 1 2 53 0-9 Step Keypad Entry Operation Set Input Output Functions (0 - is default) Select a code Prog Input Door Release Button Door Release Button Door Release Button Door Release Button Door Release Button Door Contact AUX IO 1 Door Contact Door Contact Door Contact Card And PIN Fire Override Follow AUX IO 2 Door Alarm Buzzer Interlock Interlock Interlock Door Alarm Buzzer Buzzer Buzzer Follow 0 1 2 3 4 5 6 7 8 9 3 4 1-8 (optional)* Press Door Contact Follow Door Contact Door Alarm Fire Override Interlock Card And PIN Interlock Select each door this function is valid for End Quick IO setup 11 ACTsmart Operating and Installation Manual Rev. 1. 2 Programming a Network System Up to 8 ACTsmart devices can be connected on the network. See the ACTsmart Network Installation diagram to complete the necessary connections. Programming Door Numbers Set a Master To allow some users through a door and prevent access to other users, each ACTsmart on the network must be given a door number (1-8). An ACTsmart Proximity Only Unit requires a door number if it is to be programmed with advanced options. This device will be used for programming the entire network and should be a PIN and Prox unit. The other ACTsmarts on the network (door numbers 2-8) are referred to as Slave Units. [. . . ] if card number 99 needs to be deleted, present card number 100 Operation Programming the Door Relay Time: Step 1 2 3 4 5 Present Programming Card Programming Card Programming Card Programming Card Programming Card Present Wait for 4 seconds, Buzzer sounds indicating timing. . . Operation Default ACTsmart: 1 2 3 4 5 6 Programming Card Programming Card Programming Card Programming Card Programming Card Present Card (Not Programming Card) Step Buzzer sounds intermittently and the LED flashes RED to warn you are about to default the system Default ACTsmarts. Note: This deletes the Programming Card. 14 ACTsmart Standalone Installation Diagram 15 Access Control Technology, Unit C1, South City Business Centre, Tallaght, Dublin 24, Ireland. Tel: 353-1-4662570 Fax: 353-1-4520427 UK Locall: 0845 300 5204 Web: http://www. accesscontrol. ie E-mail: sales@accesscontrol. ie ACTsmart Fire Alarm Override Connections 16 ACTsmart Interlock Connections Access Control Technology, Unit C1, South City Business Centre, Tallaght, Dublin 24, Ireland. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ACT ACTSMART




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ACT ACTSMART will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.