User manual ACT ACTPRO IOM

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ACT ACTPRO IOM. We hope that this ACT ACTPRO IOM user guide will be useful to you.


ACT ACTPRO IOM : Download the complete user guide (470 Ko)

You may also download the following manuals related to this product:

   ACT ACTPRO IOM DATASHEET (322 ko)

Manual abstract: user guide ACT ACTPRO IOM

Detailed instructions for use are in the User's Guide.

[. . . ] Examples of this are elevator control, alarm systems, CCTV switching and general monitoring. A maximum of 4 I/O modules maybe connected to any single controller, giving control of up to 32 relays and 32 inputs per ACT2000/ACT3000. Features · · · · · · · · 8 form C relays 8 supervised inputs Tamper protection 2 status LEDs Timer for each output Input Timer Output switched ON/OFF by log event, input or timezone ACTWinPro support ACTWinPro Support · · · · · · · Named inputs and outputs Inputs and outputs Logged Normally open/closed. Active on timezone Active on event, user, door or user group Active on input on/off Active on output on/off 1 ACTPro IOM ver 1. 0 Applications Elevator control In this application, a user presents a card to the proximity reader when he enters the cab. The buttons stay on for a programmable amount of time (normally 5 seconds) and then switch off. Alarm Systems The unit can be programmed to fire a relay on alarm events such as tamper, door forced, mains fail etc. [. . . ] Finally, click the Accept icon . Step 2. The inputs section of the screen allows each input to be assigned its own name. This is the name that will appear in the log when the input changes state. Inputs can be enabled by timezone and when an output is on. While the input is enabled, it can be logged (if the Log tick box is checked) or it can generate an Alarm when it goes active. 4 ACTPro IOM ver 1. 0 For example, you may want the input to be monitored only during the day or only when a particular output is on. The Normally Open option allows the input to be in the normal state when the contact is open and active when the contact is closed. If the Supervised option is checked, then two 4k7 resistors are required (see the wiring diagram at the end of the manual). This allows the IOM to check for tampers and shorts across the input contacts. The Timer option selects the amount of time the input must remain in a certain state before the change is reported. This prevents a momentary change in the input from causing a false alarm. If any inputs are unused, simply set the Enable Timezone to Not Active. Step 3. Each output can be assigned an individual name. The Options section allows the input to Logged as it changes state, to be Normally On or to act as an Elevator Floor. By selecting a timezone from the Active Timezone drop-down box, the relay can be made activate during this timezone. Output On Events / Output Off Events section allows events occurring on a Door to turn the Output relay on or off. The available event groups are Access Granted, Access Denied, Door Alarm, Fire, Technical Fault, Door Armed, Door Disarmed. Access Granted event group consists of Access/Exit grant event including push button exit. The Door Alarm event group consists of the ajar, forced and duress events. Technical Faults event group consists of Tamper/Mains Fault and Offline events. 5 ACTPro IOM ver 1. 0 Elevator Control Elevator control is one particular application of the IOM ACTWinPro allows programming of users, permitting them access to different floors in an elevator lift shaft at different times. However controllers maybe networked giving control of more floors. Step 1. The first step is to select the Elevator Floor option for the output. Notice that all the other options are greyed-out. Step 2. Click on the Floor Groups option under the Database drop-down box. to generate a new Floor Group in the database. Select a Click the New icon controller that the Floor Group will belong to and assign the Floor Group a name. Finally, click the Accept icon . Step 3. All the outputs that are assigned the Elevator Floor option AND belong to the selected controller will appear in the Floors not in Group box on the left. [. . . ] Supervised inputs maybe in one of 4 states, Normal, Active, Short or Open circuited. Supervised inputs required the installer to provide 2 resistors per Supervised input as shown below. 4k7 IP1 4k7 0V ACT3000 OP7 OP8 NO NC C NC C NO OP1 OP2 NC C NO If the Mains Present or Door Contact inputs are not used, they should be linked to 0V TAMPER MAINS PRESENT 12V DC B A OV 12345678 NO NC C NC C NO + - 8 7 6 5 OV OV 1 2 3 4 NC C NO INPUTS On OP5 OP6 TX RX NETWORK 1 A B 0V SETTING IO MODULE ADDRESS IO Module address is set via the DIP switches. Up to 4 IO Modules maybe connected to a ACT2000/3000 controller. IO Module Addr 1: 12345678 On A B 0V A B Shield DOORS A/B/OV RS485 WIRING To next Door or IO Module Total Length max 1. 4km IO Module Addr 2: 12345678 On IO Module Addr 3: 12345678 On IO Module Addr 4: 12345678 On FACTORY DEFAULT This unit should be reset to its factory default condition before installation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ACT ACTPRO IOM




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ACT ACTPRO IOM will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.