User manual ACT ACT 10 DIGITAL KEYPAD

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ACT ACT 10 DIGITAL KEYPAD. We hope that this ACT ACT 10 DIGITAL KEYPAD user guide will be useful to you.


ACT ACT 10 DIGITAL KEYPAD : Download the complete user guide (986 Ko)

Manual abstract: user guide ACT ACT 10 DIGITAL KEYPAD

Detailed instructions for use are in the User's Guide.

[. . . ] · Don't forget to change the programming code to something known only to yourself. Important: As with any Access Control system, always ensure there is an alternate means of escape in the event of the unit failing to operate due to power loss or in the event of fire. Product Specification Number of Users Supply Voltage Current Consumption Operating Temperature Door Open Time Relay Contact Rating Controller Size (H x W x D): Controller Weight Installation Mounting Output Rating 10 PIN Codes 12 ­ 24 Volts AC or DC 40mA (nominal), 120mA (maximum) -10 to +50 degrees C 0 - 255 seconds 5A / 250Vac 138 x 87 x 37 (mm) 700 grams Indoor or Outdoor (IP54) Surface or Flush 100mA Ordering Information ACT 10 Digital Keypad ACT 10 Flush Kit ACT 10 Weather Shield ACT 10 ACT 10 FK ACT 10 WS 2 ACT 10 Digital Keypad Operating & Installation Instructions 30 Second Programming Guide (For typical Standalone System) 1. Change User 1 Code On the digital keypad press button 0, then press 1. Note: The ACT 10 Digital Keypad may be returned to its factory default condition at any time by entering the programming mode and pressing the button three times. For Door 2 Operation 1. [. . . ] The red and green indicators are controlled by the door contact and the release button inputs inputs respectively, and the built in buzzer is controlled by the interlock input. When set, two or more keypads may be interlocked so that only one controlled door may be open at any one time. The interlock output is active whenever the relay is active or when the door contact is open. When the interlock input is active, the release button and all codes are inactive, the red indicator flashes. The interlock outputs and inputs of any number of keypads may be combined on a single wire. When set, all user codes, and the programming code, are six digits long. The default user one code becomes 123456 and the default programmer code becomes 999999. When set, two different codes must be entered within 15 seconds in order to open the door. The outputs activated are those which have been programmed for the first code to be entered. When set, the buzzer output is activated, if the door contact opens when a valid code has not been entered. When set, the top five user codes (5-9) are inactive any time the interlock input is activated. When set, the keypad illumination is normally off, but will switch on in response to any key being pressed or while in programming mode. When set, and the door contact has been open for longer than the time programmed into the door ajar timer, the built­in and external buzzers sound intermittently. The buzzers may be silenced by closing the door and entering a valid code. When set (default) and when the button on the keypad is pressed, the buzzer output is activated for the duration programmed into the guest buzzer timer. When set, the relay is held active whenever the interlock input is active, and the green indicator will flash. [. . . ] 12345 Push OP3 Button Duress 0123456789 Door OP2 Contact Interlock RELAY OUTPUTS OUTPUTS DOOR 2 Important Always Place Varistor +V ! Across All Lock Terminals INPUTS Important Guest Buzzer Always Place Varistor 100mA max Output sink = Across All Lock Terminals +V ! N/O C N/C Batch: 20xx-1 TAMPER Product:ACT10 Rev3. 0 Serial No. 12345 0123456789 Volt - Free Tamper Contacts N/O C N/C Output sink = 100mA max +V Power Supply 12-24V ACDC 0V Guest Buzzer Door Release Button for Door 2 Door Release Button for Door 2 The ACT 10 may be used to control 2 doors as illustrated in the diagram above RELAY DOOR 2 Break Glass Unit (optional) Door 2 +V Power Supply 12-24V ACDC 0V Shows connection for normally Shows connection for energised lock, (e. g. normally ENERGISED magnetic lock). lock (e. g. magnetic lock) 6 Break Glass Unit (optional) Door 2 Shows connection for normally ENERGISED Figure 1: ACT10 Digital Keypad Schematic Figure 2: ACT 10 Digital Keypad Schematic 220/240 Volts AC ACT 10 Digital Keypad Operating & Installation Instructions PSU 12/24 Volts AC/DC 3 Outputs (100mA) Tamper 3 Inputs (100mA) Figure ACT 10 Digital Keypad - Guide to outdoor in exposed areas Figure 3:2: ACT10 Digital Keypad_Guide to outdoor installation installation in exposed EXIT areas DO silcone all screw mounting positions and cable entry. DO NOT apply silicone to the bottom of the keypad as this will block the air vents and trap any water which may enter the keypad If a weather shield is fitted the same applies DO apply silicone to the top and two sides of the keypad, or shield, when used. DO install a weather shield when the keypad is 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ACT ACT 10 DIGITAL KEYPAD




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ACT ACT 10 DIGITAL KEYPAD will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.