User manual 3M INSULATION DISPLACEMENT CONNECTORS (IDCS) BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual 3M INSULATION DISPLACEMENT CONNECTORS (IDCS) BROCHURE. We hope that this 3M INSULATION DISPLACEMENT CONNECTORS (IDCS) BROCHURE user guide will be useful to you.


3M INSULATION DISPLACEMENT CONNECTORS (IDCS) BROCHURE : Download the complete user guide (247 Ko)

Manual abstract: user guide 3M INSULATION DISPLACEMENT CONNECTORS (IDCS) BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Our Electrical Products Division designs and manufactures a comprehensive line of products that can address your diverse applications. Widely recognized for our innovation, reliability and global corporate strength, 3M has the products and services you need and the name you trust. For over 30 years, 3M has been designing connectors with the reliability and ease of installation that electricians demand. [. . . ] · Sealant is a mineral 316IR oil-based grease. IDCs for Electrical Applications Connector 314* 314U* 316IR 557* 558* 560 Type Connector Special Features Moisture Resistant Seal Dry Environment Applications Moisture Resistant Applications Dual Element Connection Flame Retardant Flame Retardant Run & Tap Splicing Flame Retardant Run & Tap Splicing Dry Environment Applications Dual Element Connection Maximum Insulation 0. 155" (3, 94 mm) 0. 155" (3, 94 mm) 0. 155" (3, 94 mm) 0. 120" (3, 05 mm) 0. 120" (3, 05 mm) 0. 145" (3, 68 mm) AWG (mm2) Wire Range 22-14 (0, 5-1, 5) 22-14 (0, 5-1, 5) 22-16 (0, 5-1, 5) 22-16 (0, 5-1, 5) 22-16 (0, 5-1, 5) 18-16 (0, 75-1, 5) Solid/Stranded 14 Stranded 18-16 (0, 75-1, 5) Solid/Stranded 14 Stranded 18-16 (0, 75-1, 5) Solid/Stranded 14 Stranded 12-10 (3, 0-4, 0) Solid/Stranded 10 Stranded 18-14 (0, 75-1, 5) 18-14 (0, 75-1, 5) Tap 12-10 (3, 0-4, 0) Run 18-16 (0, 75-1, 5) Solid/Stranded 14 Stranded 18-16 (0, 75-1, 5) Solid/Stranded 14 Stranded 18-14 (0, 75-1, 5) 22-18 (0, 5-1, 0) Tap 18-14 (0, 75-1, 5) Run 22-18 (0, 5-1, 0) Tap 18-14 (0, 75-1, 5) Run 22-18 (0, 5-1, 0) 18-14 (0, 75-1, 5) 12 (3, 0) 18-14 (0, 75-1, 5) Operating UL, CSA or CE Temperature Certified 105°C (221°F) 105°C (221°F) 105°C (221°F) 105°C (221°F) 105°C (221°F) 105°C (221°F) -- 560B 0. 145" (3, 68 mm) 90°C (194°F) 560N 0. 145" (3, 68 mm) 105°C (221°F) 562 0. 190" (4, 82 mm) 90°C (194°F) 564 567 0. 145" (3, 68 mm) 0. 145" (3, 68 mm) Tap 0. 190" (4, 82 mm) Run 0. 145" (3, 68 mm) 90°C (194°F) 105°C (221°F) 804 Moisture Resistant Applications Dry Environment Applications Disconnect Low Voltage (Automotive) Applications Low Voltage (Automotive) Applications T-Tap Disconnect T-Tap Disconnect T-Tap Disconnect Fuse Holder 75°C (167°F) 804U 0. 145" (3, 68 mm) 75°C (167°F) 901 905 0. 145" (3, 68 mm) 0. 110" (2, 79 mm) Tap 0. 145" (3, 68 mm) Run 0. 110" (2, 79 mm) Tap 0. 145" (3, 68 mm) Run 0. 150" (3, 81 mm) 0. 150" (3, 81 mm) 0. 150" (3, 81 mm) 0. 150" (3, 81 mm) 90°C (194°F) 90°C (194°F) -- 905N 90°C (194°F) -- 951 952 953 972 105°C (221°F) 105°C (221°) 105°C (221°) 90°C (194°F) -- *Also tested in accordance with UL Standard for Portable Electric Lamps, UL 153 paragraph 15, when housed within the body of the lamp. IDCs for Communication Applications Connector U1B** U1R** UAL** Type Connector Special Features Full Pair Full Pair For Aluminum Copper Maximum Insulation 0. 125" (3, 18 mm) 0. 125" (3, 18 mm) 0. 082" (2, 08 mm) Outside port 0. 076" (1, 93 mm) Center port 0. 050" (1, 27 mm) 0. 082" (2, 08 mm) 0. 082" (2, 08 mm) 0. 066" (1, 67 mm) 0. 082" (2, 08 mm) Outside Port 0. 076" (1, 93 mm) Center Port 0. 060" (1, 52 mm) 0. 066" (1, 67 mm) 0. 066" (1, 67 mm) 0. 082" (2, 08 mm) 0. 082" (2, 08 mm) 0. 060" (1, 52 mm) 0. 082" (2, 08 mm) 0. 082" (2, 08 mm) AWG (mm2) Wire Range 16-19 (1, 3-0, 9) Solid Wire 19-24 (0, 9-0, 5) Solid Wire 17-20 (1, 15-0, 5) Solid Wire 19-24 (0, 9-0, 5) Copper 19-26 (0, 7-0, 4) Solid Wire 19-26 (0, 9-0, 4) Solid Wire 19-26 (0, 9-0, 4) Solid Wire 19-26 (0, 9-0, 4) Solid Wire 19-26 (0, 9-0, 4) Solid Wire Operating UL, CSA or CE Temperature Certified -40 to 285°F (-40 to 140°C) -40 to 285°F (-40 to 140°C) -40 to 285°F (-40 to 140°C) -- -- -- UB** UB2A** UB2A-D** UG** ULG** Moisture Resistant Seal RUS Listed Full Featured RUS Listed Full Featured Moisture Resistant Seal For large insulations -40 to 285°F (-40 to 140°C) -40 to 285°F (-40 to 140°C) -40 to 285°F (-40 to 140°C) -40 to 285°F (-40 to 140°C) -40 to 285°F (-40 to 140°C) -- -- -- -- -- UP2** UP3** UR** UR2** UR2-D** UY** UY2** UY2-D** ** Solid wire only. Dry Flame Retardant Dry Flame Retardant Moisture Resistant Seal RUS Listed Full Featured Dry Full Featured Moisture Resistant Seal RUS Listed Full Featured Dry Full Featured 22-26 (0, 7-0, 4) Solid Wire 19-26 (0, 9-0, 4) Solid Wire 19-26 (0, 9-0, 4) Solid Wire 19-26 (0, 9-0, 4) Solid Wire 19-26 (0, 9-0, 4) Solid Wire 22-26 (0, 7-0, 4) Solid Wire 19-26 (0, 9-0, 4) Solid Wire 19-26 (0, 9-0, 4) Solid Wire -40 to 285°F (-40 to 140°C) -40 to 285°F (-40 to 140°C) -40 to 285°F (-40 to 140°C) -40 to 285°F (-40 to 140°C) -40 to 285°F (-40 to 140°C) -40 to 285°F (-40 to 140°C) -40 to 285°F (-40 to 140°C) -40 to 285°F (-40 to 140°C) -- -- -- -- -- -- -- -- Insulation Displacement Connectors Features Squeeze shut connector Crimp with slip-joint pliers Unique "U" contact, fully insulated No need to cut run wire No need to twist on Benefits No stripping or twisting No special tools required Provides dependable connections Faster installation, minimum clean up Easy on hands · Many 3M IDCs are either UL-Listed (file No. · UL Listed and CSA Certified products have a voltage rating of 600V maximum for building wire, 1000V maximum for signs or lighting fixtures (luminaries). · The 3MTM E-9BM Crimping Tool is recommended for installing 3M IDCs. 3 557 IDC* Application: Electrically connects two wire ends and insulates the connection. · Designed for control circuit wiring, fixture wiring, appliance wiring, signal and PA systems, automotive/boat/RV wiring. · Rated up to 567 600 volts. 558 557 560B IDC Application: Electrically connects a (tap) wire end to a through (run) wire and insulates the connection. · For general-purpose electrical connections on auto, boat, van or trailer. · Used for tap and parallel splicing. 560B 804 804U 972 IDC Application: Used to install a blade type automotive fuse between power source and device. 951, 952, & 953 IDCs Application: Used to electrically tap into a wire in mid-span without cutting or stripping the wire. Connector then mates with 3M 0. 250" (6, 35 mm) male tabs, making a quick-connect wiring connection. · Used for tap splicing. 951 558 IDC* Application: Electrically connects a (tap) wire end to a through (run) wire and insulates the connection. · Designed for control circuit wiring, fixture wiring, appliance wiring, signal and PA systems, automotive/boat/RV wiring. 562 IDC Application: Electrically connects a (tap) wire end through a (run) wire and insulates the connection. Color: Yellow 560 & 560N IDCs Application: Electrically connects a (tap) wire end to a through (run) wire and insulates the connection. 560 · Used for tap and parallel splicing. 804 & 804U IDCs Application: Electrically connects a (tap) wire end to a through (run) wire; insulates and provides a moistureresistant seal for the connection. · Sealant-filled connector is suitable for RV trailers, boats, fleet vehicles and other environmentally sensitive applications where corrosive elements such as road chemicals, salt spray and exhaust fumes might be encountered. · Used for tap splicing. 972 905 952 953 UB2A & UB2A-D IDCs Application: UB2A makes a moisture-resistant butt splice connection between two solid-copper conductors of air-core or filled cable. · Sealant is a mineral oil-based grease. UR UP2 UR2-D 901 564 560N 564 IDC Application: Electrically connects two through (run) wires and insulates the connection. 567 IDC Application: Electrically connects a (tap) wire end to a through (run) wire and insulates the connection. [. . . ] Our capability doesn't stop with electrical products, it starts there. To explore the many ways we can serve you, contact your 3M representative today. E-9BM Crimping Tool · For use with most Scotchlok connectors. E-9C Cartridge Tool with Case · Holds connectors (in cartridges) firmly in place, allowing the craftsperson use of the other hand for guiding wires. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE 3M INSULATION DISPLACEMENT CONNECTORS (IDCS) BROCHURE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual 3M INSULATION DISPLACEMENT CONNECTORS (IDCS) BROCHURE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.